Loading...
HomeMy WebLinkAbout928 JEFFERSON ST fil741 INVOICE DATE DUE DATE INVOICE# TOTAL DUE ����� ' �,,, 11/16/2018 01/17/2019 2019-00010200 $80.00 fertoo �o Customer#: 3446 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable SON RISE DAYCARE 715 Mulberry St 928 JEFFERSON ST WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION -928 JEFFERSON ST- 10-25-18 FOR BILLING INQUIRY: (319)291-4323 L Description I Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 3446 11/16/2018 01/17/2019 2019-00010200 $80.00 Less Prepayment $0.00 Total Due— $80.00 City of Waterloo Corn,. rci ,l Fire Inspection Report Inspection Number 1870 Prior Inspection Fill this field if it is available, it will auto-fill business name and address. Number Inspector* Brock Weliver Waterloo Fire Rescue 425 E 3rd Street Waterloo, IA 50703 Phone(319)883-1615 Email: Brock.Weliver@waterloo-ia.org File Upload Address* 928 Jefferson St. Business name SonRise Christian School Inspection Date* 10/25/2018 Proprietor Tish Jacobsen Business Phone 319-235-6191 /319-961-4215 Email* preschool@sonrisewaterloo.com Email 2 Property Owner Open Bible of Waterloo Emergency Contact Aaron Keller Information Phone 319-290-9963 Violations Ref# CODE Violation &Location Corrected Ref# CODE Violation &Location Corrected 1 2015 IFC Building Services and Systems Section 605 Electrical Equipment,Wiring and Hazards 605.5 Extension cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures,extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. 2015 IFC Building Services and Systems Section 605 Electrical Equipment,Wiring and Hazards 605.4 Multiplug adapters. Multiplug adapters,such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. *An extension cord with a multi plug adapter end was found to be plugged into a television in the Nursery Room. *Corrective action, discontinue the use of extension cords for permanent wiring. 2 2015 IFC Means of Egress Section 1008 Means of Egress Illumination 1008.2 Illumination required.The means of egress serving a room or space shall be illuminated at all times that the room or space is occupied. 2015 IFC Means of Egress Section 1013 Exit Signs 1013.6.3 Power source. Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss,the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or an on-site generator.The installation of the emergency power system shall be in accordance with Section 604. *Exit/Egress lights were found to be out when tested. *Batteries are on order for all of these lights *Staff personnel are able to perform function tests of these lights. If periodic testing of these lights are performed, please keep a log and document the date,time, results and name/signature of person performing these tests. Comments: Contact your contractor(Proshield)about the hood suppression system.The tag was out of date,they had provided service to the rest of your building and systems.The report may be emailed to me at the address above. You may also email me a log of the Egress/Exit lights when the new batteries have been installed. We will schedule a tentative re-inspection 3 weeks from today for the items above. Once the items have been corrected,email the above records and the inspection will be closed/completed. If violations noted during the inspection are not corrected by the given re-inspection date, additional fees are as follows: $100,00-First Re-inspection I$150.00-Second Re-inspection I$200-Third and subsequent Re-inspections Reports Reports Annual Fire Sprinkler Comment Black Hawk Sprinkler, 10-31-2017 *Next annual inspection is scheduled to be performed in upcoming weeks Reports Annual Fire Alarm Comment Proshield,4-25-2018 Reports Fire Extinguisher Service Comment Proshield,Apr 2018 Reports Semi-Annual Kitchen hood Cleaning for all Hoods Comment B&B Vent, 7-10-2018 Reports Semi-Annual Kitchen hood Fire Suppression for all Hoods Comment Please provide current report, report may be emailed to the email address above If testing, inspection or servicing is due, please arrange to have it performed *Make contact with contractor about this item, may have been done, tag was old Reports Comment Fire Door, in kitchen, Overhead Door 9-27-2018 Reports Comment Fire Drills, monthly log, last performed 9-26-2018 Inspection Fee $ 70.00 Occupancy Fee $ 10.00 Re-inspection Fee S Total Fee* $ 80.00 Received By AN INVOICE OF THIS CHARGE WILL FOLLOW. DO NOT PAY FROM THIS FORM. File Upload (for long inspections) Reinspection Re-inspection# Date Time 11/15/2018