Loading...
HomeMy WebLinkAbout89 FRANKLIN ST INVOICE DATE DUE DATE INVOICE# TOTAL DUE jig. /61411, NM. 11/16/2018 01/17/2019 2019-00010201 $80.00 °kbrloo �o Customer#: 9868 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable SALVATION ARMY 715 Mulberry St 89 FRANKLIN WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 89 FRANKLIN ST- 10-25-18 FOR BILLING INQUIRY: (319)291-4323 1 Description ( Total Price J INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 9868 11/16/2018 01/17/2019 2019-00010201 $80.00 Less Prepayment $0.00 Total Due—* $80.00 City of Waterloo Com rcial Fire Inspection Report Inspection Number 1871 Prior Inspection Fill this field if it is available, it will auto-fill business name and address. Number Inspector* Brock Weliver Waterloo Fire Rescue 425 E 3rd Street Waterloo, IA 50703 Phone(319)883-1615 Email: Brock.Weliver@waterloo-ia.org File Upload Address* 89 Franklin St Business name The Salvation Army Inspection Date* 10/25/2018 Proprietor Martin Ainsworth Business Phone 319-235-9358 Email* MARTIN AINSWORTH@USC.SALVATIONAR MY.ORG Email 2 Property Owner The Salvation Army Emergency Contact Martin Ainsworth Information Phone 319-464-1797 • Violations Ref# CODE Violation &Location Corrected 1 2015 IFC General Requirements Section 315 General Storage 315.3.1 Ceiling clearance. Storage shall be maintained 2 feet or more below the ceiling in nonsprinkiered areas of buildings or not less than 18 inches below sprinkler head deflectors in sprinklered areas of buildings. *Multiple areas of the building had storage in violation of the clearances above. *Corrective action, maintain storage in all areas of the building to the clearances described above. Ref# CODE Violation &Location Corrected 2 2015 IFC Building Services and Systems Section 605 Electrical Equipment,Wiring and Hazards 605.5 Extension cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. *An extension cord was found in the Youth Center Area that was extended up through the ceiling and came back out of the ceiling and connected to Christmas lights around a pole. *Corrective action, extension cords are only to be used as described above 3 2015 IFC Building Services and Systems Section 605 Electrical Equipment, Wiring and Hazards 605.10.4 Prohibited areas. Portable,electric space heaters shall not be operated within 3 feet of any combustible materials. Portable,electric space heaters shall be operated only in locations for which they are listed. *Portable space heaters were found in the Sunday Nursery area *Corrective action, discontinue the use of portable space heaters • Ref# CODE Violation &Location Corrected 4 2015 IFC Building Services and Systems Section 609 Commercial Kitchen Hoods 609.3.3 Cleaning. Hoods, grease-removal devices,fans, ducts and other appurtenances shall be cleaned at intervals as required by Section 609.3.3.1 through 609.3.3.3 2015 IFC Building Services and Systems Section 609 Commercial Kitchen Hoods 609.3.3.1 Inspection. Hoods,grease-removal devices, fans, ducts, and other appurtenances shall be inspected at intervals specified in Table 609.3.3.1 or as approved by the fire code official. Inspections shall be completed by qualified individuals. 2015 IFC Building Services and Systems Section 609 Commercial Kitchen Hoods 609.3.3.3 Records. Records for inspections shall state the individual and company performing the inspection,a description of the inspection and when the inspection took place. Records for cleaning shall state the individual and company performing the cleaning and when the cleaning took place.Such records shall be completed after each inspection or cleaning and maintained. 2015 IFC Building Services and Systems Section 609 Commercial Kitchen Hoods 609.3.3.3.1 Tags.When a commercial kitchen hood or duct system is inspected, a tag containing the service provider name,address, telephone number and date of service shall be provided in a conspicuous location. Prior tags shall be covered or removed. 2015 IFC Building Services and Systems Section 609 Commercial Kitchen Hoods Table 609.3.3.1 Commercial Cooking System Inspection Frequency Type of Cooking Operations • High-volume cooking operations such as 24-hour cooking, charbroiling or wok cooking, Frequency of Inspection 3 months • Low-volume cooking operations such as places of religious worship, seasonal businesses and senior centers, Frequency of Inspection 12 months •Cooking operations utilizing solid fuel-burning cooking appliances, Frequency of Inspection 1 month •All other cooking operations, Frequency of Inspection 6 months *Hood Cleaning Report is needed for both kitchens,this report may be emailed to the email address above. Ref# CODE Violation &Location Corrected 5 2015 IFC Fire and Smoke Protection Features Section 703 Fire- Resistance-Rated Construction 703.2.2 Hold-open devices and closers. Hold-open devices and automatic door closers,where provided, shall be maintained. During the period that such device is out of service for repairs,the door it operates shall remain in the closed position. *Multiple doors in the building had kick-stand type hold open devices on them or foot wedge type hold open devices. Contact you Fire Alarm contractor to install magnetic/electronic hold open devices if you would like to keep doors opened. Many of these doors are fire-rated doors and need to be closed in the event of a fire. This helps compartmentalize and stops the spread of smoke and flame throughout the building. 6 2015 IFC Means of Egress Section 1008 Means of Egress Illumination 1008.2 Illumination required.The means of egress serving a room or space shall be illuminated at all times that the room or space is occupied. 2015 IFC Means of Egress Section 1013 Exit Signs 1013.6.3 Power source. Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss,the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Section 604. *Exit and Egress lights were found to be out when tested *Lights were in the hallway by the Logan Ave exit doors and in the Martin Bros. Building Exit door. *Corrective action, repair or replace Exit/Egress lights 7 2015 IFC Means of Egress Section 1010 Doors, Gates and Turnstiles 1010.1.9 Door operations. Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. *Door in the hallway leading from the main entrance back to the youth center had a keyed lock above the panic hardware for the door. *Corrective action, remove keyed lock from the door. 8 2015 IFC Fire Protection Systems Section 901 General 901.4 Installation. Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection where the building is altered, remodeled or added to.Alterations to fire protection systems shall be done in accordance with applicable standards. *Ceiling tiles were missing in the youth center storage room. *Corrective action, replace ceiling tiles Comments: Have the Waterloo Building Department review any work and permits for the work that was performed in the Martin Bros. Building/garage bay area. There is a mezzanine in this area that is potentially obstructing exit/egress doors. If violations noted during the inspection are not corrected by the given re-inspection date, additional fees are as follows: $100.00-First Re-inspection I$150.00-Second Re-inspection I$200-Third and subsequent Re-inspections Reports Reports Annual Fire Alarm Comment Proshield Please provide current report, report may be emailed to the email address above If testing, inspection or servicing is due, please arrange to have it performed Reports Annual Generator Service Comment Please provide current report, report may be emailed to the email address above If testing, inspection or servicing is due, please arrange to have it performed Reports Semi-Annual Kitchen hood Cleaning for all Hoods Comment Please provide current report, report may be emailed to the email address above If testing, inspection or servicing is due, please arrange to have it performed Reports Semi-Annual Kitchen hood Fire Suppression for all Hoods Comment Proshield, May 2018 Reports Fire Door Comment Christie Door Company, Chapel Kitchen, 09-12-2018 Main Kitchen, needs test/report Please provide current report, report may be emailed to the email address above If testing, inspection or servicing is due, please arrange to have it performed Reports Fire Extinguisher Service Comment Proshield, May 2018 Reports Comment Dryer vent, Please provide current report, report may be emailed to the email address above If testing, inspection or servicing is due, please arrange to have it performed **Dryer vent/exhaust cleaning/maintenance should be done in accordance with manufacturer's recommendations. Document the date,time, personnel performing maintenance and signature. Maintenance/cleaning may be done by maintenance/staff personnel. ***Vent was not hooked up to the water exhaust filter Inspection Fee $ 70.00 Occupancy Fee $ 10.00 Re-inspection Fee S Total Fee* S 80 00 Received By AN INVOICE OF THIS CHARGE WILL FOLLOW. DO NOT PAY FROM THIS FORM. File Upload (for long inspections) Reinspection Re-inspection# Date Time 11/15/2018