Loading...
HomeMy WebLinkAbout360 WESTFIELD AVE (2) INVOICE DATE DUE DATE INVOICE# TOTAL DUE / i,,+�F, t. 02/09/2018 03/15/2018 2018-00000157 $610.00 NIS °ferloo \o Customer#: 22261 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable CEDAR VALLEY TECHWORKS 715 Mulberry St 360 WESTFIELD AV WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-360 WESTFIELD AVE-2-1-18 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price J INSPECTION 100,000 $600.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 22261 02/09/2018 03/15/2018 2018-00000157 $610.00 Less Prepayment $0.00 Total Due- $610.00 City of Waterloo Fire Inspection Report Commercialr. p Inspection Number 1248 Prior Inspection Fill this field if it is available, it will auto-fill business name and address. Number Inspector* Chris Ferguson Waterloo Fire Rescue 425 E 3rd Street Waterloo, IA 50703 Phone(319)493-1025 Email: chris.ferguson@waterloo-ia.org File Upload Address* 360 Westfield Business name Techworks-TechOne Inspection Date* 2/1/2018 Proprietor Techworks Business Phone 319-232-1156 Email* WJames@cedarvalleyalliance.com Email 2 Property Owner Emergency Contact Information Phone Violations CODE Violation &Location Corrected Ref# 1 2015 IFC: Section 1104.5 Illumination Emergency Power-All egress lighting found on 6th floor did not illuminate when test button was pushed. Corrective Action: provide corrective action so that egress lights illuminate when test button is pressed. 2 2015 IFC:Section 1104.3 Exit Sign Illumination- Exit signs shall be internally or externally illuminated. Exit sign found above the south exit stair tower door on the 6th floor did not illuminate. Provide corrective action to ensure exit sign illuminates. Ref# CODE Violation &Location Corrected 3 Combustible storage located on 5th floor-foam products. Please remove foam products currently stored on 5th floor in accordance with agreement regarding sprinkler coverage. 4 2015 IFC: Section 1104.3 Exit Sign Illumination: Exit signs shall be internally or externally illuminated. Exit sign found above the north stair tower door on the 3rd floor did not illuminate. Provide corrective action to ensure exit sign illuminates. 5 2015 IFC:Section 703.2 Opening Protectives: Fire doors and smoke barrier doors shall not be blocked or obstructed...Fire doors in the 3rd floor elevator area were found to be blocked open. Doors were signed to remain closed at all times. Provide corrective action so that doors remain closed or will close upon activation of fire alarm. 6 2015 IFC: Section 703.2.3 Door operation: Fire doors shall close...and latch automatically. Fire doors on 3rd floor leading into the"Maker's Space"did not close and latch. Please provide corrective repair. 7 2015 IFC: Section 703.2.3 Door operation: Fire doors shall close...and latch automatically. Fire doors near 2nd floor elevator lobby did not close and latch. No striker plate was present for door to latch into. Please provide corrective repair. 8 2015 IFC: Section 703.2.3 Door operation: Fire doors shall close...and latch automatically. Fire doors on 2nd floor boiler room did not close and latch. Please provide corrective repair 9 2015 IFC: Section 901.6 Inspection,testing and maintenance- Fire detection and alarms...shall be maintained in an operative condition at all times. Smoke detector in the 2nd floor elevator lobby was found to be covered. Corrective action: remove cover and ensure detector is functional. 10 2015 IFC: Section 1031 Maintenance of the means of egress- Egress light was found on floor, fallen from wall in the north half of the first floor. Replace light and ensure it is operating. 11 2015 IFC:Section 901.4 Installation- Fire protection systems shall be maintained in accordance with the installation standards for that system. Sprinkler piping was found to have old wiring still attached to it in the 2nd floor elevator lobby. Please remove anything attached to sprinkler piping that is not related to the operation of the sprinkler system. (Per Simplex Sprinkler Report) 12 2015 IFC: Section 703.1 Fire-resistance-rated construction-A ceiling tile was found to be missing in Wes'Office. Corrective action: replace ceiling tile in office. 13 2015 IFC: Section 906.2 Portable fire extinguisher general requirements: Portable fire extinguishers shall be serviced annually.The fire extinguisher next to the main sprinkler riser on 1st floor was found to be past due for annual inspection. Please provide annual servicing of the extinguisher. Comments: It is recommended that this property institute a monthly or bi-monthly egress light and exit sign check program due to the number found to be inoperable. Spot checking will occur during re-inspection. Feel free to contact me with any questions or concerns you may have.Thank you for your time and cooperation. If violations noted during the inspection are not corrected by the given re-inspection date,additional fees • are as follows: $100.00 -First Re-inspection I$150.00-Second Re-inspection I$200 Third and subsequent Re-inspections Reports Reports Annual Fire Sprinkler Comment Tyco-Simplex Grinnell-07/20/2017: See item 11 above. Reports Annual Fire Alarm Comment Tyco-Simplex Grinnell-01/16/2018: No deficiencies noted on report. Inspection Fee $ 600.00 Occupancy Fee $ 10.00 Re-inspection Fee $ Total Fee* $ 610.00 Received By Wes James AN INVOICE OF THIS CHARGE WILL FOLLOW. DO NOT PAY FROM THIS FORM. File Upload (for long inspections) Reinspection Re-inspection# Date Time 1 3/6/2018 0930