Loading...
HomeMy WebLinkAbout264 BALTIMORE ST INVOICE DATE DUE DATE INVOICE# TOTAL DUE 7�11� 11/20/2022 2023-00020282 $150.00 ��+�,��■ ���, 10/17/2022 t‘'5177-=_4tr 4'11erloo ° Customer#: 23001 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable QUALITY CONCRETE CONTRUCTION(RENTAL) 715 Mulberry St 1930 HAWTHORNE AVE#1 WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION- 264 BALTIMORE ST- 8-15-22 FOR BILLING INQUIRY: (319)291-4323 L Description I Total Price J REINSPECTION FEE 2ND $150.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23001 10/17/2022 11/20/2022 2023-00020282 $150.00 Less Prepayment $0.00 Total Due — $150.00 City of Waterloo �� � ���� 0��0��� ' �� � �J����"� ����� d������«�� ' INSPECTION REPORT � QUALITY CONCRETE CONSTRUCTION 4 FAMILY CONVERSION,264BALTIMORE ST, WATERLOO � IA 50701 DETAILS Inspection Date:08/15/2022 | Inspection Type: Rental Inspection \ Inspection Number:8344 } Shift: N/A ( Scation: N/A i Unit: N/A \ Lead Inspector: BARHY5TR/TTOm \ Other Inspectors: N/A | Fee:$1SO.88 �� *°. ^r ' Snorus CODE ofmcR/pr/uN F�|L 1010.1.9 Door operations Except as specifically permitted by this section,egress doors shall be readily openable frorn the egress side without the use of a key or special knowledge or effort. Inspector: BARRYSTR/TTOm Comments:Doors not weather tight. FAIL 1831.7 Emergency escape Required emergency escape and rescue openin�sshall ben�ainrainedinaccordance and rescue openings with the code in effect at the time of construction,and the following: Required | emergency escape and rescue openings shall be operational from the inside of the | room without the use of keys o/'tools. Bars'grilles,grates or similar devices are ! allowed tobe placed over emer�encyescape and /'escueopenings provided the ' minimum net clear opening size complies with the code that was in effect at-the time of construction and Such devices shall be releasable or removable from tile inside without the use of a key,tool or force greater than that which is required for normal operation nf the emergency escape and rescue opening. Inspector: BARRYSTRxTTON Comments:Windows screwed shut and windows do not open and close. FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and exiscina Group A'B.E'F, H. |' w1' R')'R'2' R'4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A: 1 O-B:C.2.Within 30 feet(9144 n-im) of commercial cooking equipment. 3. In areas where flammable or combustible liquids are stored, used or dispensed.4. On each floornf Structures under construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms' where required by the fire code official. Inspector: BARRvSTR^TT0N Comments: Primed=m,`soo22 Cc`237 Page 1m4 STATUS CODE DESCRIPTION FAIL 907l11 Single-and Listed single and multiple-station smoke alarms complying,with UL217 shall be mu|dp|e'ssaticmsmoke installed in accordance with Sections 9O72.11.1 through 9O7.l11.6 and NFP472. alarms Inspector: BARRYSTRATTUw Comments:Smoke detectors need cube installed (n bedroom and outside of the bedroom. FAIL 915.1 Genera/ Cat-bon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector: 8ARRYSTRATTOm Comments: Need[O detector installed FAIL R4 Exterior Property Areas |s the exterior property area maintained ina clean,safe,and sanitary condition?This includes�nadingand drainage,sidewalks and dr�eway�weed�and pest infestations.(/Pm[302) Inspector: 8ARRvSTRATTOw [ommenrs:Handrails on front steps need repaired/rep|aced. FAIL R8 Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound, and ina sanitary condition?(|pK«[305) Inspector: BARRv5TRATTON [omments: Peeling paint,exposed pipe inbedroom, bath ceiling failing in,holes in floor,windows,egress path blocked,need bath fall installed inbathroom. New tenant it)unit without corrections being done. GENERAL NOTES BARRYSTRATT0N-U8/l5/2822@12:34 304.13 Window,sky|i�hrand door frames. Every window,sky|igh� door and�ameshaU be kept in sound condition,good repair and weather tight BARRYSTR/QTON 88/15/2022@12:35 3O4.14 Insect screens. During the period from[DATE]no[DATE].every door,window and other outside opening required for ventilation of habitable rooms,food preparation areas,food service areas or any areas where products to be included or utilized in food for human consumption are processed, manufactured, packaged or stored shall be supplied with approved tightly fitting screens of minimum 16 mesh per inch(16 mesh per 25 mm),and every screen door used for insect control shall have a self-closing device in good working condition. BARRvSTnATTON 88/15/2822@12:35 304.15 Doors. Exterior cloors, door assemblies,operator systerns if provided,and hardware shall be maintained in good condition. Locks ax all entrances todwelling units and sleeping units shall tightly secure the door. Locks on means of egress cloors shall bein accordance with Section 782.3. p'..^=", az�� `2yr GENEM NOTES eARRvSTKAlT0N 08/15/2022@12:35 305.3 Interior Surfaces. Interior Surfaces, including windows and doors,shall be maintained in good,clean and sanitary condition. Peeling,chipping,flaking or abraded paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall becorrected. BAKRvSTRATTON 08/15/2022 @ 12:35 305.4 Stairs and walking surfaces. Every stair,rarnp,landing,balcony, porch,deck or other walking surface shall be maintained in sound condition and good repair BARRYSTRATTOm 08/15/2022@12:35 403.2 Bathrooms and toilet rooms. Every bathroom and toilet room shall comply with the ventilation requirements for habitable spaces as required by Section 403.1,except that a window shall not be required in such spaces equipped with amechanical ventilation system.Air exhausted bya mechanical ventilation system from abathroom or toilet room shall discharge to the outdoors and shall not be recirculated.(Need to install bath fan). aARxvSTR/QT0N 08/15/2022@a12:35 5O4.1 General. Plumbing fixtures shall be properly installed and maintained inworking order,and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. Plumbing fixtures shall be maintained in a safe'sanitary and functional condition.(Need to install new sanitary drain on kitchen sink.Slinky pipe is not allowed). BARRYSTRAlTON 08/15/2022@ 1236 305.5 Handrails and guards. Every handrail and guard shall be firmly fastened and capable Of Supporting normally imposed loads and shall be maintained in good condition.(Handrai|son front szeps). 8xRRvSTKxTTON 08/15/2022@12:36 702.1 General.A safe,continuous and unobstructed path of travel shall be provided from any point in a building or structure to the public way. Means of egress shall comply with the International Fire Code.(Obstructions in egress path in hallway and entry door) BARRvSTKATTON 88/15/2022@p12:36 9-7-6: DENIAL,SUSPENSION, REVOCATION OR NONRENEWAL:3. Failure to correct deficiencies noted in notices ofviolation within the time specified in the notice. BARRvsTRATTOm 08/15/2022@ 12:36 ]64 Baltimore Sx#2 mE/mSvecr/omoArc O0/ZZ/ZU22 px"°m""mv's�c��`o, Page 3o/4 • CONTACT SIGNATURE Dan Reyerson Signed on:08/15/2022 @ 12:36 INSPECTOR SIGNATURE BARRY STRATTON Signed on:08/15/2022 @ 12:37 QUESTIONS AIOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 P-',zed on 03,I 5/2022,f;12 37 Page 4 of 4 /\ WATERLOO ` ����0 �������n� mmmm� o�������"��� INSPECTION REPORT `^ QUALITY CONCRETE MULTI UNIT COMPLEX,200 INDEPENDENCE AVE, WATERLOO IA 50703 mcoo/Lo Inspection Date:UO/Z3/20Z2 \ Inspection Type: Rental Inspection ( Inspection Number:83g6 \ Shift- N/A \ Sraton: N/A \ Unit: N/A \ Lead inspector:BARRYSTRATTON Other Inspectors: N/A \ Fee:$150.UQ �� _ ��x�f ^�� �~m'=�p � STATUS CODE DESCRIPTION FAIL 1010'1.9 Door operations Exceptas specifically permitted by this secdon'egress doors shall bereadily openable from the egress side without the use of a key or special knowledge or effort. Inspector: 8ARRYSTRATTON Comments: FAIL 1031.7 Emergency escape Required emergency escape and rescue openings shall be maintained in accordance with h d in effect at time of and the fo|�ovv>n�' Required and rescue openings vvr the e ' . emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars'grilles,grates o/'similar devices are allowed to be placed over emergency escape and rescue openings provided the minimum net dear opening size complies with the code that was in effect at the time of construction and Such devices shall be releasable or removable from the inside without the use of a key,tool or force greater than that which is required for normal operation of the emergency escape and rescue opening. Inspector:BARRYSTR/gTON Comments: Bedroom in basemenc no egress window FAIL 605.1 Abatement of identified electrical hazards shall be abated. identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought tothe attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or clarnaged and constitutes an electrical shock or fire hazard shall not be used. � Inspector:8ARRv STRATTON Comments:238V dryer outlet no working FAIL 605.5 Extension cords Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed uzstructures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental clarnage or physical impact. Extension cords shall be used only with portable appliances. inspector:BxRRYSTnATTOm Comments: p,m"uo"no/zszozz�``.o` ^ . ~ STATUS CODE DESCRIPTION FAIL 906.1 Where required Portable fire extinguishers shall be installed in all of the following locations: 1. in new and existing Group A, 8' E. F, H. \.k4' R'1. R'2, R-4and Soccupancies. Exception: In Group R'2nocupandes, pot-table fire extinguishers shall be required only in locations specified in Iterns 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of1f\: 1O'8:C.Z.Within 30 feet(g144mm) of commercial cooking equipment.3.m areas where flammable orcombustible liquids are stored, used or dispensed.4.On each floor nf structures under construction, except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas' including but not limited to laboratories,computer rooms and generator rooms, where required by the fire code official. Inspector: BARRYSTR/TTON Comments: FAIL R5'Interior Structure Has the interior of the Structure and equipment inside been maintained in good repair,structurally Sound,and in a sanitary condition?(|P;N[3O5) Inspector: BARRYSTRATTON Comments:Holes in walls,kitchen sink cabinet needs replaced,kitchen ceiling has holes, Kitchen cabinets missing doors,broken basement windows, replace all broken glass.float in toilet needs replaced. Peeling and abraded paint throughout. Kitchen cabinets failing off cabinet. Kitchen sink will not drain and is still leaking into a tub under sink. FAI L Rb.A.'Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions Inspector: BARRYSTRATTON Comments:Bathroom mold/walls water damage FAIL R6.B. Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of68F?(|PrwC6O2.2) Inspector: 8ARRYSTRATTON Comments:Missing register covers and noinspection done on new furnace. FAIL R6.[. rNpchanica|Eqiupmenr Are mechanical appliances properly installed and maintained in good working condition?(\Pk4C6UI1) Inspector: BARnvSTnATTON Comments:Water heater installed with out permits and inspections and missing discharge tube. 6EmexALmmTES BARRY STRATT ON 08/23/2022Ca�10:59 304.13VVindmw'sky|i8htanddonrfrmmes. Everywindow.sky|ight,doorandframesha|| be kept in sound condition,good repair and weather tight w"teuonmvz�20z Cc�``o` Page zur* ' GENERAL NOTES 8ARRYSTnA7T0N 08/23/2022@10:59 504.1 Genet-al. Plumbing fixtures shall be properly installed and maintained in working order,and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. Plumbing fixtures shall be maintained in a safe,sanitary and functional condition. Bathroom shower needs new surround and new faucet/shower head installed on tub.Toilet also needs new float installed intoilet. 8ARRY5TR/QT0N 08/23/2022 @ 11/00 604.3 Electrical system hazards.Where it is found that the electrical system in a structure constitutes a hazard to the occupants or the structure by reason of inadequatesen/ice' improperfusing'insufficientreceptadeand |ightingout|ets, improper wiring or installation, deterioration or damage,or for similar reasons,the code official shall require the defects to be corrected to eliminate the hazard. BARRYSTRAlTON 08/23{2022@»11:00 305.3 Interior surfaces. Interior surfaces,including windows and doors,shall be maintained in good,clean and sanitary condition. Peeling,chipping,flaking or abraded paint shall be repaired, removed or covered.Cracked or loose plaster-,decayed wood and other defective surface conditions shall becorrected. BARRY STRATTON 88/23/2022 @ 1 1:0O 109.4 Violation penalties.Any person who shall violate a provision of this code'or fail to comply therewith,or with any of the requirements thereof,shall be prosecuted within the limits provided by state or local laws. Each day that a violation continues after due notice has been served shall be deemed a separate offense. 8ARRv STKATTQN 08/23{2022 @ 1 1:8U 308.1 Accumulation of rubbish or garbage. Exterior property and premises'and the interior of every structure,shall be free from any accurnulation of rubbish or garbage. Rear egress off the back porch there is combustible storage and storage in the egress path. BARnvSTRATrON 08/23/2822@ 11:00 702.1Genera}.A safe,continuous and unobstructed path of travel shall beprovided from any point in a building or structure to the public way. Means of egress shall comply with the international Fire Code. BARRYSTKA7TON 08/23/2022@11:01 702.2 Aisles.The required width of aisles in accordance with the International Fire Code shall beunobstructed. nE/msPECnomDArE 0g/27/2022 =',."v=no/,sznzz�t,`.u, Page om* . . CONTACT SIGNATURE Quality Concrete Signed on:08/23/Z822@ 11:01 INSPECTOR S16mAnURE axRRYSTRAlTON ^— Signed on:08/23/2U2Z@)11:01 ---- QUESTIONS ABOUT YOUR INSPECTION? BARKvSTRATTON oarry.strauon@water|oo ia.org (319)231-9147 Printed��'�,'zu��``n' Page 4nr4