HomeMy WebLinkAbout1202 W 2ND ST INVOICE DATE DUE DATE INVOICE# TOTAL DUE
/iiii�� cir.N Ili 10/17/2022 11/20/2022 2023-00020284 $250.00
kiAte'%%
Gterloo No
Customer#: 23001 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
QUALITY CONCRETE CONTRUCTION(RENTAL) 715 Mulberry St
1930 HAWTHORNE AVE#1 WATERLOO, IA 50703
WATERLOO,IA 50702
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
RENTAL INSPECTION - 1202 W 2ND ST-9-12-22 FOR BILLING INQUIRY: (319)291-4323
1.
Description I Total Price
REINSPECTION FEE 3RD $250.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
23001 10/17/2022 11/20/2022 2023-00020284 $250.00
Less Prepayment $0.00
Total Due —> $250.00
City of Waterloo
WATERLOO FIRE RESCUE
INSPECTION REPORT r
QUALITY CONCRETE MULTI-RESIDENTIAL RENTALS, 1202 W 2NU ST, WATERLOO IA 50701 `Ro.
DETAILS
Inspection Date:09/12/2022 I Inspection Type: Rental Inspection I Inspection Number:8492 I Shift: N/A I Station: N/A
Unit: N/A I Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$250.00 1/0°( /‘_44_.
STATUS CODE DESCRIPTION
FAIL 1018.1 -General Aisles and aisle accessways serving as a portion of the exit access in the means of
egress system shall comply with the requirements of this section.Aisles or aisle
accessways shall be provided from all occupied portions of the exit access that
contain seats,tables,furnishings,displays and similar fixtures or equipment.The
minimum width or required capacity of aisles shall be unobstructed.Exception:
Encroachments complying with Section 1005.7.
Inspector:BARRY STRATTON-Comments:
FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector: BARRY STRATTON-Comments:Doors and jambs
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRY STRATTON-Comments: Missing globes, electric panel blocked,and
appliances in basement blocking egress path.
Painted on O9/'2,2022 Lam'2:29
Page 1 of 4
`
S TwToS cmmE oescmonnom
FAIL 703.1 Maintenance The required fire-resistance rating offi re-resimance-rated construction,including,
but not limited to,walls,firestops, shaft enclosures, partitions,smoke barriers,
floors,fire-resistive coatings and sprayed fire-resistant materials applied to
structural members and fire-resistant joint systems,shall be maintained.Such
elements shall be visually inspected by the owner annually and properly repaired,
restored or replaced where clarnaged, altered,breached or penetrated. Records of
inspections and repairs shall be maintained.Where concealed,such elements shall
not be required to be Visually inspected by the owner-unless the concealed space is
accessible by the removal or movement of panel,access door'ceiling tile or similar
movable entry to the space.Openings made therein for the passage of pipes,
electrical conduit,wires,ducts,air transfer openings and holes made for any reason
shall be protected with approved methods capable of resisting the passage of smoke
and fire. Openings through fire-resista nce-rated assemblies shall be protected by
self-or autornatic-closing cloors of approved construction meeting the fire protection
requirements for the assembly.
Inspector: 8ARRYSTRAlTUN Comments:Ceiling in living room'walls in living room,
water damageto walls,ceilings,and floors.
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new
and existing Group A, B' E' F' *' |. rN. R'1'R'2,R-4 and S occupancies. Exception: In
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a pot-table
fire extinguisher having a minimum racing of 1-A:1O'B:C.J.Within 30 feet(9144 mm)
of commercial cooking equipment. 3. In areas where flammable or combustible
liquids are stored, used nr dispensed.4.Un each floor of structures under
construction,except Group R-3 occupancies,in accordance with Section 3315.1. 5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas,
including but not limited to|aboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector: BARnv5TnA770m Comments:
FAIL 907.2.11 Single-and Listed single-and multiple-station smoke alarms complying with ULZ17 shall be
mu|tip|estarionsmoke installed in accordance with Sections g07.Z.11.1 through y87.2.11.6 and NFPA7Z.
alarms
Inspector:BARRYSTR/TTON Comments:
FAIL 915.1 General Cat-bon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 11OIy.
Inspector: BAKRvSTR/QTUN Comments:
FAIL R1 Unsafe SUuCtures Is the structure found to be dangerous to the life, health, property or safety of either
the public or occupants of the Structure?(|Prw[ 10O.1.1)
p^nt°""om`2Y20z '-T,/�29
Page 2or4
STATUS CODE DESCRIPTION
Inspector: BARRY STRATTON-Comments: Not habitable
FAIL R3-Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPMC
Occupancy 108.1.3)
Inspector: BARRY STRATTON-Comments:
FAIL R5-Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and
sanitary state?(IPMC 304)
Inspector:BARRY STRATTON-Comments: Deck stairs and railing
FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector:BARRY STRATTON-Comments: Entry door needs replaced.jamb and door
are broken. Broken windows need replaced. Egress path is blocked in kitchen
because refrigerator is blocking path. Ceiling in living room has collapsed.Ceiling tiles
are damaged by water leak.bath sink is not secured to wall in bathroom. Sewer leak
in basement needs repaired by licensed professional.Screen door does not have any
door hardware. Back door to 1202 did not function because tenant advised it is
broken. Security hardware to keep door secured in jamb is broken and jamb not
capable to keep door secured and weather tight.
•
FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector: BARRY STRATTON-Comments:Mold and water damage
FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector: BARRY STRATTON-Comments:Furnace can not maintain 68 degrees with
all the broken windows in building. Maintenance to furnace needed and new windows
need installed in building.This issue was noted back in October 2021.
REINSPECTION DATE
10/10/2022
--ed or,p9'"
Page 3 of 4
CONTACT SIGNATURE
Quality Concrete Construction
Signed on:09/12/2022 @ 12:29 EMAL
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:09/12/2022 @ 12:29
QUESTIONS ABOUT YOUR INSPECTION?
BARRY STRATTON
barry.stratton@waterloo-ia.org
(319)231-9147
P,,nted on 09/12/2022 g 12:29
Page 4 of 4