1RENTAL INSPECTION- 1200 MEADOW LN F- 7-26-22 FOR BILLING INQUIRY: (319)291-4323
Description I Total Price
REINSPECTION FEE 2ND $150.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
23270 10/17/2022 11/20/2022 2023-00020289 $150.00
Less Prepayment $0.00
Total Due $150.00
City of Waterloo
-
� ",0°
WATERLOO FIRE RESCUE °
INSPECTION REPORT wf aE
30 SOMETHING REAL ESTATE LLC, 1200 MEADOW LN, WATERLOO IA 50702
DETAILS
Inspection Date:07/26/2022 I Inspection Type: Rental Inspection I Inspection Number:8244 I Shift: N/A I Stati n: N/A
Unit: N/A I Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$150.00 9Ai
go/ i/, j4J'
STATUS CODE DESCRIPTION
FAIL 1010.1.9-Door operations Except as specifically permitted by this section,egress doors shall be readily
openable from the egress side without the use of a key or special knowledge or
effort.
Inspector: BARRY STRATTON-Comments:Front door needs replaced.
FAIL 1010.1.9.4-Bolt locks Manually operated flush bolts or surface bolts are not permitted. Exceptions: 1.On
doors not required for egress in individual dwelling units or sleeping units.2.Where
a pair of doors serves a storage or equipment room,manually operated edge-or
surface-mounted bolts are permitted on the inactive leaf.3.Where a pair of doors
serves an occupant load of less than 50 persons in a Group B,F or S occupancy,
manually operated edge-or surface-mounted bolts are permitted on the inactive
leaf.The inactive leaf shall not contain doorknobs,panic bars or similar operating
hardware.4.Where a pair of doors serves a Group B, F or S occupancy,manually
operated edge-or surface-mounted bolts are permitted on the inactive leaf provided
such inactive leaf is not needed to meet egress capacity requirements and the
building is equipped throughout with an automatic sprinkler system in accordance
with Section 903.3.1.1.The inactive leaf shall not contain doorknobs,panic bars or
similar operating hardware. 5.Where a pair of doors serves patient care rooms in
Group 1-2 occupancies,self-latching edge-or surface-mounted bolts are permitted on
the inactive leaf provided that the inactive leaf is not needed to meet egress capacity
requirements and the inactive leaf shall not contain doorknobs,panic bars or similar
operating hardware.
Inspector: BARRY STRATTON-Comments:Latch locks/padlocks on interior bedroom
doors need removed.
Pr'irted s..-`25i2O22 t^a 1;15
Page 1 of 4
� ^ =
STATUS CODE OfmCRxPTxON
FAIL 703.1 Maintenance The requiredfirp'resistance rating nffire'resismnce'racedconstruction,inc|uding,
but not limited to,walls,firestops, shaft enclosures, partitions,smoke barriers,
floors,fire-resistive coatings and sprayed fire-resistant materials applied ro
structural members and fire-resistant joint systems'shall be maintained.Such
elements shall be visually inspected by the owner annually and properly repaired,
restored or replaced where damaged,altered, breached or penetrated. Records of
inspections and repairs shall be maintained.Where concealed,such elements shall
not be required to be visually inspected by the owner unless the concealed space is
accessible by the removal or movernent of a panel,access door,ceiling tile or similar
movable entry no the space.Openings made therein for the passage ofpipes,
electrical conduit,wires,ducts,air transfer openings and holes made for any reason
shall be protected with approved methods capable of resisting the passage of smoke
and fire. Openings through fire'resistance'rated assemblies shall be protected by
self-or autornatic-closing doors of approved construction meeting the fire protection
requiremenoa for the assembly.
Inspector:8ARRvSTRATTON Comments:
FAIL 703.2 Upeningprorecrives Opening protectives shall be maintained in an operative condition in accordance with
NFPA 80.Where allowed by the fire code official,the application of field-applied labels
associated with the maintenance nf opening proteoives shall follow the
requirements of the approved third-party certification organization accredited for
listing the opening protective. Fire doors and smoke barrier doors shall not be
blocked or obstructed,or otherwise made inoperable. Fusible links shall be replaced
promptly whenever fused or damaged. Fire cloor assemblies shall not be modified.
Inspector:BARRvSTRATTON Comments:
FAIL 901.6 Inspection,testing and Fire detection,alarm,and extinguishing systems,mechanical smoke exhaust
maintenance systems,and smoke and heat vents shall be maintained in an operative condition at
all times,and shall be replaced or repaired where defective. Nonrequired fire
protection systems and equipment shall be inspected,tested and maintained or
removed.
Inspector: 8ARRvSTRATT8N Comments:Alarm
FAIL 906.1 Where required Portable fire extinguishers shall be installed in all of the following locations: 1. |nnew
and existing Group A'8' E' F, n.|'rN' n'1' K'2' R'4 and 5occupancies. Exception: In
Group R'2occupandes, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of1'A: 18'8:[.2.Within 38 feet(y144mill)
of commercial cooking equipment.3. In areas where flammable or combustible
liquids are stored, used or dispensed.4. On each floor of structures under
construction, except Group R-3 occupancies, in accordance with Section 3315.1. S.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas,
including but not limited to laboratories, computer rooms and generator roorns,
where required by the fire code official.
Inspector: BARRvSTR^JTON Comments:
Printed on z)2z�`1:15
Page zo,4
STATUS CODE DESCRIPTION
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector: BARRY STRATTON-Comments:
FAIL 915.1 -Genera: Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector: BARRY STRATTON-Comments:
FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector:BARRY STRATTON-Comments:Floor inside of entrance door has large
separation at wall and floor. Floor not stable. Front door needs replaced.Door
busted a lockset
GENERAL NOTES
BARRY STRATTON-07/26/2022 a 11:15 1200 Meadow Ln#C
REINSPECTION DATE
08/26/2022
CONTACT SIGNATURE
30 Something Real Estate LLC Vk1 L
Signed on:07/26/2022 @ 11:15 / /
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:07/26/2022 @ 11:15
Page 3 of 4
QUESTIONS ABOUT YOUR INSPECTION?
BARRY STRATTON
barry.stratton@waterloo-ia.org
(319)231-9147
Printed on 07/26/2022 i 11:15
Page 4 of 4
O
WATERLOO FIRE RESCUE ro:173 oak,
INSPECTION REPORT G tel
30 SOMETHING REAL ESTATE LLC, 1200 MEADOW LN, WATERLOO IA 50702
DETAILS
Inspection Date:07/26/2022 j Inspection Type: Rental Inspection I Inspection Number:8243 I Shift: N/A I Stati 1: N/A I
Unit: N/A I Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$150.00 2 4 4 si ze, z's-'
STATUS CODE DESCRIPTION
FAIL 1010.1.9-Door operations Except as specifically permitted by this section,egress doors shall be readily
openable from the egress side without the use of a key or special knowledge or
effort.
Inspector: BARRY STRATTON-Comments:
FAIL 1029.11.1 -Walking surface The surface of aisles,stepped aisles and ramped aisles shall be of slip-resistant
materials that are securely attached.The surface for stepped aisles shall comply with
Section 1011.7.1.
Inspector:BARRY STRATTON-Comments: Rear entrance floor needs repaired.
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector:BARRY STRATTON-Comments:need globes on all lights and electric
outlets broken and missing covers.
FAIL 703.1 -Maintenance The required fire-resistance rating of fire-resistance-rated construction,including,
but not limited to,walls,firestops, shaft enclosures, partitions,smoke barriers,
floors,fire-resistive coatings and sprayed fire-resistant materials applied to
structural members and fire-resistant joint systems,shall be maintained.Such
elements shall be visually inspected by the owner annually and properly repaired,
restored or replaced where damaged,altered,breached or penetrated. Records of
inspections and repairs shall be maintained.Where concealed,such elements shall
not be required to be visually inspected by the owner unless the concealed space is
accessible by the removal or movement of a panel,access door,ceiling tile or similar
movable entry to the space.Openings made therein for the passage of pipes,
electrical conduit,wires,ducts,air transfer openings and holes made for any reason
shall be protected with approved methods capable of resisting the passage of smoke
and fire. Openings through fire-resistance-rated assemblies shall be protected by
self-or automatic-closing doors of approved construction meeting the fire protection
requirements for the assembly.
Inspector: BARRY STRATTON-Comments:
Printed on =_._ 09:33
Page 1 of 5
STATUS COD' DESCRIPTION
FAIL 703.1.2-Smoke barriers and Required smoke barriers and smoke partitions shall be maintained to prevent the
smoke partitions passage of smoke. Openings protected with approved smoke barrier doors or smoke
dampers shall be maintained in accordance with NFPA 105.
Inspector:BARRY STRATTON-Comments: Need smoke seals
FAIL 703.2 - Opening protectives Opening protectives shall be maintained in an operative condition in accordance with
NFPA 80.Where allowed by the fire code official,the application of field-applied labels
associated with the maintenance of opening protectives shall follow the
requirements of the approved third-party certification organization accredited for
listing the opening protective. Fire doors and smoke barrier doors shall not be
blocked or obstructed,or otherwise made inoperable. Fusible links shall be replaced
promptly whenever fused or damaged. Fire door assemblies shall not be modified.
Inspector: BARRY STRATTON-Comments:Smoke seals
FAIL 901.6- 'nspection,testing and Fire detection,alarm,and extinguishing systems,mechanical smoke exhaust
maintenance systems,and smoke and heat vents shall be maintained in an operative condition at
all times,and shall be replaced or repaired where defective. Nonrequired fire
protection systems and equipment shall be inspected,tested and maintained or
removed.
Inspector: BARRY STRATTON-Comments:Alarm
FAIL 901.6.1 -Standards Fire protection systems shall be inspected,tested and maintained in accordance with
the referenced standards listed in Table.
Inspector:BARRY STRATTON-Comments:
FAIL 901.6.2- Records Records of all system inspections,tests and maintenance required by the referenced
standards shall be maintained.
Inspector: BARRY STRATTON-Comments:
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new
and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exception: In
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm)
of commercial cooking equipment.3. In areas where flammable or combustible
liquids are stored, used or dispensed.4. On each floor of structures under
construction,except Group R-3 occupancies, in accordance with Section 3315.1.5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas,
including but not limited to laboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector: BARRY STRATTON-Comments:2019
Printed on 0-__ -- -_--
Page 2 of 5
t t
STATUS CODE DESCRIPTION
FAIL 907.2.10.1 -Manual fire alarm A manual fire alarm system that activates the occupant notification system in
system accordance with Section 907.5 shall be installed in Group R-4 occupancies.
Exceptions: 1.A manual fire alarm system is not required in buildings not more than
two stories in height where all individual sleeping units and contiguous attic and
crawl spaces to those units are separated from each other and public or common
areas by not less than 1-hour fire partitions and each individual sleeping unit has an
exit directly to a public way,egress court or yard.2. Manual fire alarm boxes are not
required throughout the building where all of the following conditions are met:2.1.
The building is equipped throughout with an automatic sprinkler system installed in
accordance with Section 903.3.1.1 or 903.3.1.2.2.2.The notification appliances will
acti-vate upon sprinkler water flow.2.3. Not fewer than one manual fire alarm box is
installed at an approved location.3. Manual fire alarm boxes in resident or patient
sleeping areas shall not be required at exits where located at all nurses'control
stations or other constantly attended staff locations,provided such stations are
visible and continuously accessible and that the distances of travel required in
Section 907.4.2.1 are not exceeded.
Inspector: BARRY STRATTON-Comments:
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector: BARRY STRATTON-Comments:
FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector: BARRY STRATTON-Comments:Kitchen cabinets broken missing drawer
fronts.Thermostat falling off wall,windows do not lock,front door jamb and door
broken missing door seals,Walls in bathroom need repaired and mold removed, Bed
bugs and cockroaches in building
FAIL R6.A.- Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector: BARRY STRATTON-Comments: Infestation, Electrical, Fire Safety
FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector:BARRY STRATTON-Comments: Exhaust fan over stove does not work.
Stove door broken and stove needs replaced.
Printed on 07/26/20 : 09:38
Page 3 of 5
STATUS CODE DESCRIPTION
FAIL R6.D.- Receptacles Every habitable space in a dwelling shall contain not less than two separate and
remote receptacle outlets. Every laundry area shall contain not less than one
grounding-type receptacle or a receptacle with a GFCI. Every bathroom shall contain
not less than one receptacle.Any new bathroom receptacle shall have GFCI
protection.All receptacles shall have the appropriate faceplate cover.(IPMC 605.2)
Inspector:BARRY STRATTON-Comments:
GENERAL NOTES
BARRY STRATTON-07/26/2022 @ 09:37 305.4 Stairs and walking surfaces. Every stair, ramp,landing,balcony,porch,deck or
other walking surface shall be maintained in sound condition and good repair
BARRY STRATTON-07/26/2022 @ 09:37 304.15 Doors. Exterior doors,door assemblies,operator systems if provided,and
hardware shall be maintained in good condition. Locks at all entrances to dwelling
units and sleeping units shall tightly secure the door. Locks on means of egress doors
shall be in accordance with Section 702.3.
BARRY STRATTON-07/26/2022 @ 09:37 304.13 Window,skylight and door frames. Every window,skylight,door and frame shall
be kept in sound condition,good repair and weather tight.
BARRY STRATTON-07/26/2022 @ 09:37 304.18 Building security. Doors,windows or hatchways for dwelling units, room units
or housekeeping units shall be provided with devices designed to provide security for
the occupants and property within
BARRY STRATTON-07/26/2022 @ 09:37 603.1 Mechanical equipment and appliances. Mechanical equipment,appliances,
fireplaces,solid fuel-burning appliances,cooking appliances and water heating
appliances shall be properly installed and maintained in a safe working condition,and
shall be capable of performing the intended function
BARRY STRATTON-07/26/2022 @ 09:38 605.1 Installation. Electrical equipment,wiring and appliances shall be properly
installed and maintained in a safe and approved manner.605.2 Receptacles. Every
habitable space in a dwelling shall contain not less than two separate and remote
receptacle outlets. Every laundry area shall contain not less than one grounding-type
receptacle or a receptacle with a ground fault circuit interrupter. Every bathroom shall
contain not less than one receptacle.Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection.All receptacle outlets shall have the
appropriate faceplate cover for the location.
BARRY STRATTON-07/26/2022 @ 09:38 1200 Meadow Ln Unit#D
Printed on 07/26/2022 Le.09:38
Page 4 of 5
� I R
REINSPECTION DATE
08/26/2022
CONTACT SIGNATURE
30 Something Real Estate LLC _ r14 _`L
Signed on:07/26/2022 @ 09:38 1
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:07/26/2022 @ 09:38
QUESTIONS ABOUT YOUR INSPECTION?
BARRY STRATTON
barry.stratton@waterloo-ia.org
(319)231-9147
Pr rated on 07/`26/2022 kc 09:38
Page 5 of 5
WATERLOO FIRE RESCU �/
J ��YLNtryr,
INSPECTION REPORT
30 SOMETH
ING REAL ESTATE LLC, 1200 MEADOW CN, WATERLC?41A 50702
DETAILS
Inspection Date:07/26/2022 I Inspection Type: Rental Inspection I Inspection Number: €3242 Shift: N/A i Station: N/A I
Unit: N/A Lead Inspector:BARRY STRATTON f Other Inspectors: N/A I Fee:$150.00
ti° 6-016 d7M/4
STATUS CODE DESCRIPTION
FAIL 1010.1.9- Door operations Except as specifically permitted by this section,egress doors shall be readily
openable from the egress side without the use of a key or special knowledge or
effort.
Inspector: BARRY STRATTON-Comments:Front door to Unit#F
FAIL 1031.7-Emergency escape Required emergency escape and rescue openings shall be maintained in accordance
and rescue openings with the code in effect at the time of construction,and the following: Required
emergency escape and rescue openings shall be operational from the inside of the
room without the use of keys or tools. Bars,grilles,grates or similar devices are
allowed to be placed over emergency escape and rescue openings provided the
minimum net clear opening size complies with the code that was in effect at the time
of construction and such devices shall be releasable or removable from the inside
without the use of a key,tool or force greater than that which is required for normal
operation of the emergency escape and rescue opening.
Inspector: BARRY STRATTON-Comments:Windows leak
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRY STRATTON-Comments:Need globes on lights.
Pr!nted on v-_:20?;'OG: 9
Page 1 of 4
STATUS CODE DESCRIPTION
FAIL 703.1 - Maintenance The required fire-resistance rating of fire-resistance-rated construction,including,
but not limited to,walls,firestops, shaft enclosures, partitions,smoke barriers,
floors,fire-resistive coatings and sprayed fire-resistant materials applied to
structural members and fire-resistant joint systems,shall be maintained.Such
elements shall be visually inspected by the owner annually and properly repaired,
restored or replaced where damaged, altered, breached or penetrated. Records of
inspections and repairs shall be maintained.Where concealed, such elements shall
not be required to be visually inspected by the owner unless the concealed space is
accessible by the removal or movement of a panel,access door,ceiling tile or similar
movable entry to the space.Openings made therein for the passage of pipes,
electrical conduit,wires,ducts,air transfer openings and holes made for any reason
shall be protected with approved methods capable of resisting the passage of smoke
and fire. Openings through fire-resistance-rated assemblies shall be protected by
self-or automatic-closing doors of approved construction meeting the fire protection
requirements for the assembly.
Inspector: BARRY STRATTON-Comments:Need smoke seals on doors.
FAIL 901.6-Inspection,testing and Fire detection,alarm,and extinguishing systems, mechanical smoke exhaust
maintenance systems,and smoke and heat vents shall be maintained in an operative condition at
all times,and shall be replaced or repaired where defective. Nonrequired fire
protection systems and equipment shall be inspected,tested and maintained or
removed.
Inspector:BARRY STRATTON-Comments:Alarm in building still has not had
maintenance and testing.
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new
and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exception: In
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm)
of commercial cooking equipment. 3. In areas where flammable or combustible
liquids are stored, used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas,
including but not limited to laboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector: BARRY STRATTON-Comments:
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector: BARRY STRATTON-Comments:Detectors missing. Detectors shall be
installed throughout building and apartments.
Printed on 0 i2E,-_--t-a^09:29
Page 2 of 4
STATUS CODE DESCRIPTION
FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector:BARRY STRATTON-Comments:
FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector: BARRY STRATTON-Comments: Holes in wall behind mirror in bathroom.
Ceiling in living room and common hallway are falling and need repaired. Peeling
paint in unit and common hallway. Furnace filter needs changed and ceilings cleaned
from all dirt around vents.
FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
inspector: BARRY STRATTON -Comments:
FAIL R6.B.- Residential Heating Are dwellings provided with heating facilities capable of maintaining a room
temperature of 68F?(IPMC 602.2)
Inspector: BARRY STRATTON-Comments:Furnace filter
GENERAL NOTES
BARRY STRATTON-07/26/2022 @ 09:28 305.3 Interior surfaces. Interior surfaces,including windows and doors,shall be
maintained in good,clean and sanitary condition. Peeling,chipping,flaking or abraded
paint shall be repaired, removed or covered.Cracked or loose plaster,decayed wood
and other defective surface conditions shall be corrected.
BARRY STRATTON-07/26/2022 @ 09:29 Unit#F
REINSPECT ION DATE
O8/26/2022
Printed on 07/26/2022 to 09:29
Page 3 of 4