Loading...
HomeMy WebLinkAbout1738 FLOWER ST #3 INVOICE DATE DUE DATE INVOICE# TOTAL DUE f/r;1� -; ;, 10/17/2022 11/20/2022 2023-00020293 $150.00 %rloo •o Customer#: 10811 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable DOMINIC TANGEN 715 Mulberry St 2501 SCENIC DR WATERLOO, IA 50703 CEDAR FALLS, IA 50613 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION- 1738 FLOWER ST#3 - 8-31-22 FOR BILLING INQUIRY: (319)291-4323 Description i _.. I Total Price j REINSPECTION FEE 2ND $150.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 10811 10/17/2022 11/20/2022 2023-00020293 $150.00 Less Prepayment $0.00 Total Due—> $150.00 City of Waterloo %k1 WATERLOO FIRE RESCUE 4 , ,. INSPECTION REPORT DOMINIC TANGEN RENTAL 8-PLEX, 1738 FLOWER ST, WATERLOO lA 50701 -4- DETAILS Inspection Date:08/31/2022 I Inspection Type: Rental Inspection I Inspection Number:8259 ( Shift: N/A I Station: N/A Unit: N/A I Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$150.00 . 4 `e14 7 ie STATUS CODE DESCRIPTION FAIL 1010.1.9-Door operations Except as specifically permitted by this section,egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON-Comments:Door missing on entrance to unit#3. FAIL 1018.1 -General Aisles and aisle accessways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section.Aisles or aisle accessways shall be provided from all occupied portions of the exit access that contain seats,tables,furnishings,displays and similar fixtures or equipment.The minimum width or required capacity of aisles shall be unobstructed. Exception: Encroachments complying with Section 1005.7. Inspector:BARRY STRATTON-Comments:Egress/exit lighting still not working. FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector: BARRY STRATTON-Comments: FAIL 1031.7-Emergency escape Required emergency escape and rescue openings shall be maintained in accordance and rescue openings with the code in effect at the time of construction,and the following: Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools.Bars,grilles,grates or similar devices are allowed to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of a key,tool or force greater than that which is required for normal operation of the emergency escape and rescue opening. Inspector: BARRY STRATTON-Comments:Broken windows P-in;ed on 08 31,2022 05:33 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 505.1 -Address identification New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property.Address identification characters shall contrast with their background.Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches(102 mm)high with a minimum stroke width of 1/2(12.7 mm). Where required by the fire code official,address identification shall be provided in additional approved locations to facilitate emergency response.Where access is by means of a private road and the building cannot be viewed from the public way,a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Inspector: BARRY STRATTON-Comments:Apartment numbers not posted on apartment doors. FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON-Comments:Electric panel has water damage FAIL 901.6-Inspection,testing and Fire detection,alarm,and extinguishing systems,mechanical smoke exhaust maintenance systems,and smoke and heat vents shall be maintained in an operative condition at all times,and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected,tested and maintained or removed. Inspector: BARRY STRATTON-Comments: FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A, B, E, F, H, I, M, R-1, R-2,R-4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3. In areas where flammable or combustible liquids are stored, used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies, in accordance with Section 3315.1.5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories,computer rooms and generator rooms, where required by the fire code official. Inspector: BARRY STRATTON-Comments: FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector: BARRY STRATTON-Comments: Printed on 08/31t2022 1.=06.33 Page 2 of 4 • STATUS CODE DESCRIPTION FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may include boilers,heating equipment,elevator, moving stairways, electrical wiring,and flammable liquid containers.(IPMC 108.1.2) Inspector:BARRY STRATTON-Comments:All 8 units FAIL R4- Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This includes grading and drainage,sidewalks and driveways,weeds, and pest infestations.(IPMC 302) Inspector: BARRY STRATTON-Comments:junk and debris FAIL R5- Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and sanitary state?(IPMC 304) Inspector: BARRY STRATTON-Comments: Broken windows and meter cabinet FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector: BARRY STRATTON-Comments: Building is unfit to occupy and was tagged DO NOT ENTER DO NOT OCCUPY FAIL R6.A.- Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions Inspector: BARRY STRATTON-Comments: FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F?(IPMC 602.2) Inspector: BARRY STRATTON-Comments: FAIL R6.C.- Mechanical Egiupment Are mechanical appliances properly installed and maintained in good working condition?(IPMC 603.1) Inspector: BARRY STRATTON-Comments: GENERAL NOTES P,r;e0 05:33 Page 3 of 4 BARRY STRATTON-08/31/2022 @ 06:33 Unit 3. Now all 8 are not habitable REINSPECTION DATE 10/03/2022 CONTACT SIGNATURE Dominic Tangen EA\AL Signed on:08/31/2022 @ 06:33 INSPECTOR SIGNATURE BARRY STRATTON Signed on:08/31/2022(ED 06:33 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Page 4 of 4 WATERLOO FIRE RESCUE I`N`° INSPECTION REPORT U DOMINIC TANGEN RENTAL 8-PLEX, 1738 FLOWER ST, WATERLOO IA 54701 4141106 DETAILS Inspection Date:08/31/2022 1 Inspection Type: Rental Inspection Inspection Number: 8258 ` Shift: N/A 1 Station: N/A Unit: N/A Lead Inspector:BARRY STRATTON ( Other Inspectors: N/A I Fee:$150.00 "44-f/ZJIK PS, STATUS CODE DESCRIPTION D13.3- Illumination Exit signs shall be internally or externally illuminated. Exception:Tactile signs required by Section 1013.4 need not be provided with illumination. • Inspector: BARRY STRATTON-Comments: FAIL 1025.5-Illumination Where photoluriiinescent exit path markings are installed,they shall be provided with not less than 1 footcandle(11 lux)of illumination for not less than 60 minutes prior to periods when the building is occupied and continuously during the building occupancy. Inspector: BARRY STRATTON-Comments: FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector: BARRY STRATTON-Comments: FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:BARRY STRATTON-Comments:Electric outlets missing,wire being taken out of walls,open holes in walls where switches and outlets were. FAIL 703,2-Opening protectives Opening protectives shall be maintained in an operative condition in accordance with NFPA 80.Where allowed by the fire code official,the application of field-applied labels associated with the maintenance of opening protectives shall follow the requirements of the approved third-party certification organization accredited for listing the opening protective. Fire doors and smoke barrier doors shall not be blocked or obstructed,or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged. Fire door assemblies shall not be modified. Inspector: BARRY STRATTON-Comments: Printed on 08/31/2022 tc.05:25 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 901.6-Inspection,testing and Fire detection,alarm,and extinguishing systems,mechanical smoke exhaust maintenance systems,and smoke and heat vents shall be maintained in an operative condition at all times,and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected,tested and maintained or removed. Inspector: BARRY STRATTON-Comments:Alarm is not functional FAIL 901.6.1 - Standards Fire protection systems shall be inspected,tested and mainta ned in accordance with the referenced standards listed in Table. Inspector:BARRY STRATTON-Comments: FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A,B, E, F, H, I,M,R-1, R-2,R-4 and S occupancies. Exception:In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3. In areas where flammable or combustible liquids are stored, used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1.6. Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Inspector: BARRY STRATTON-Comments: FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector: BARRY STRATTON-Comments:Smoke detectors missing throughout building and apartments. FAIL R2- Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may include boilers,heating equipment,elevator, moving stairways, electrical wiring,and flammable liquid containers.(IPMC 108.1.2) Inspector: BARRY STRATTON-Comments:Alarm,electric system and egress/exit lighting. FAIL R3-Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPMC Occupancy 108.1.3) Inspector: BARRY STRATTON-Comments:All 8 units unfit for occupancy. Printed on ``2022 is 05:25 Page 2 of 4 STATUS CODE DESCRIPTION FAIL R4- Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This includes grading and drainage,sidewalks and driveways,weeds,and pest infestations.(IPMC 302) Inspector: BARRY STRATTON-Comments:Junk and debris FAIL R5- Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and sanitary state?(IPMC 304) Inspector: BARRY STRATTON-Comments:Broken doors and windows. Electric meter box that stores meters needs attention FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound, and in a sanitary condition?(IPMC 305) Inspector:BARRY STRATTON-Comments:All 8 units need not fit for occupancy. FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions inspector: BARRY STRATTON-Comments: FAIL R6.B.- Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F?(IPMC 602.2) Inspector:BARRY STRATTON-Comments: FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition?(IPMC 603.1) Inspector:BARRY STRATTON-Comments: GENERAL NOTES BARRY STRATTON-08/31/2022 @ 06:24 Unit#2 and common areas.Also 1,3,4, 5,6,7,8 REINSPECTION DATE 10/03/2022 Printed on 08/31,2022 tc•06.25 Page 3 of 4 CONTACT SIGNATURE Dominic Tangen Signed on:08/31/2022 @ 06:24 INSPECTOR SIGNATURE BARRY STRATTON Signed on:08/31/2022 @ 06:24 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 P.^nted on 08/31/2022 C 05:25 Page 4 of 4