Loading...
HomeMy WebLinkAbout2141 LOGAN AVE INVOICE DATE DUE DATE INVOICE# TOTAL DUE �/MaI ��► kW; 10/17/2022 11/20/2022 2023-00020297 _4gitt� $150.00 'teriooAo Customer#: 14897 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable VIETH REALTY LLC 715 Mulberry St 6419 NORDIC WATERLOO, IA 50703 CEDAR FALLS, IA 50613 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 2141 LOGAN AVE - 8-11-22 FOR BILLING INQUIRY: (319)291-4323 LDescription Total Price J REINSPECTION FEE 2ND $150.00 CUSTOMER# I BILLING DATE DUE DATE INVOICE# 1489 7 10/17/2022 11/20/2022 I 2023-00020297 CHARGES $150.00 Less Prepayment $0.00 Total Due $150.00 City of Waterloo • WATERLOO FIRE RESCUE INSPECTION REPORT VIETH REALITY LLC RENTAL UNIT,2141 LOGAN AVE, WATERLOO IA 50703 (64 N" DETAILS \ /\ Inspection Date:08/11/2022 I Inspection Type: Rental Inspection 1 Inspection Number:8317 ( Shift: N/A I Station: N/A Unit: N/A " Lead Inspector: BARRY STRATTON I Other Inspectors: N/A I Fee:$150.00 2'14 ,- ;671S14 STATUS CODE DESCRIPTION FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may include boilers,heating equipment,elevator, moving stairways,electrical wiring,and flammable liquid containers.(IPMC 108.1.2) Inspector: BARRY STRATTON-Comments:Water heater in laundry area still not corrected.Appliance gas line still being used instead of the required black pipe. GENERAL NOTES BARRY STRATTON-08/11/2022 @ 10:13 6 units at 2141 Logan Ave.Only 4 units registered. BARRY STRATTON-08/11/2022 @ 10:13 Unit#5 is vacant. REINSPECTION DATE 09/15/2022 CONTACT SIGNATURE Vieth Reality LLC + 1� Signed on:08/11/2022 @ 10:13 INSPECTOR SIGNATURE BARRY STRATTON Signed on:08/11/2022 @ 10:13 �r nted on 03'1,2022 tc'...?4 Page 1 of 2 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Page 2 of 2 WATERLOO FIRE RESCUE \ ")31 INSPECTION REPORT * ` DM INVESTMENTS LC SINGLE FAMILY RENTAL, 128 MOSLEY ST, WATERLOO IA 50703 DETAILS Inspection Date:09/13/2022 I Inspection Type: Rental Inspection I Inspection Number: 8726 I Shift: N/A ( Station: N/A Unit: N/A ; Lead Inspector:BARRY STRATTON Other Inspectors: N/A j Fee:$100.00 ,66.74._Avs, STATUS CODE DESCRIPTION FAIL 1031.7-Emergency escape Required emergency escape and rescue openings shall be maintained in accordance and rescue openings with the code in effect at the time of construction,and the following: Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars,grilles,grates or similar devices are allowed to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of a key,tool or force greater than that which is required for normal operation of the emergency escape and rescue opening. Inspector: BARRY STRATTON-Comments:Windows FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON-Comments:Outlets not working. No light in 1st floor bedroom. Globes missing on lights. FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A, B, E, F, H, I, M,R-1,R-2, R-4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3. In areas where flammable or combustible liquids are stored, used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies, in accordance with Section 3315.1.S. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories,computer rooms and generator rooms, where required by the fire code official. Inspector: BARRY STRATTON-Comments: P-inted on 0911 Page 1 of 5 1 STATUS CODE DESCRIPTION FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smo`•<e installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector: BARRY STRATTON-Comments:Smoke detectors not installed to meet code requirements. FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector: BARRY STRATTON-Comments:Need CO detectors in vicinity of all bedrooms. FAIL R4- Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This includes grading and drainage,sidewalks and driveways,weeds,and pest infestations.(IPMC 302) Inspector:BARRY STRATTON-Comments:Volunteer trees growing up out of foundation. Handrail on front steps need repaired. FAIL R5-Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and sanitary state?(IPMC 304) Inspector:BARRY STRATTON-Comments:Need screens on windows and broken windows repaired.Windows need latches on windows that will secure windows. FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector: BARRY STRATTON-Comments:Broken windows,doors not fitting in openings,cracks in ceilings and walls. Peeling and abraded paint.Wall above back door,wall at top of stairs,stove not working,refrigerator compressor making noise, handrails missing to basement and upstairs. Bats in house. Basement windows missing.Tub surround has door/wood not attached to opening. FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F?(IPMC 602.2) Inspector: BARRY STRATTON-Comments:Duct work not hooked up in basement for bathroom. FAIL R6.C.-Mechanical Ediupment Are mechanical appliances properly installed and maintained in good working condition?(IPMC 603.1) Printed on 09/13r20=_ 12:53 Page 2 of 5 STATUS CODE DESCRIPTION Inspector: BARRY STRATTON-Comments:Water heater missing discharge tube. GENERAL NOTES BARRY STRATTON-09/13/2022 @ 12:45 9-7-4 9-7-5 Rental unit is not registered.$500.00 plus$95.00 citation is being issued for failure to register. BARRY STRATTON-09/13/2022 @ 12:45 302.5 Rodent harborage.Structures and exterior property shall be kept free from rodent harborage and infestation.Where rodents are found,they shall be promptly exterminated by approved processes that will not be injurious to human health.After pest elimination,proper precautions shall be taken to eliminate rodent harborage and prevent reinfestation. BARRY STRATTON-09/13/2022 12:46 304.2 Protective treatment. Exterior surfaces,including but not limited to,doors,door and window frames,cornices,porches,trim, balconies,decks and fences,shall be maintained in good condition. Exterior wood surfaces,other than decay-resistant woods,shall be protected from the elements and decay by painting or other protective covering or treatment.Peeling,flaking and chipped paint shall be eliminated and surfaces repainted.Siding and masonry joints,as well as those between the building envelope and the perimeter of windows,doors and skylights,shall be maintained weather resistant and water tight. Metal surfaces subject to rust or corrosion shall be coated to inhibit such rust and corrosion,and surfaces with rust or corrosion shall be stabilized and coated to inhibit future rust and corrosion.Oxidation stains shall be removed from exterior surfaces.Surfaces designed for stabilization by oxidation are exempt from this requirement BARRY STRATTON-09/13/2022 @ 12:46 304.5 Foundation walls. Foundation walls shall be maintained plumb and free from open cracks and breaks and shall be kept in such condition so as to prevent the entry of rodents and other pests. BARRY STRATTON-09/13/2022 @ 12:47 304.6 Exterior walls. Exterior walls shall be free from holes,breaks,and loose or rotting materials;and maintained weatherproof and properly surface coated where required to prevent deterioration. BARRY STRATTON-09/13/2022 @ 12:47 304.7 Roofs and drainage.The roof and flashing shall be sound,tight and not have defects that admit rain.Roof drainage shall be adequate to prevent dampness or deterioration in the walls or interior portion of the structure. Roof drains,gutters and downspouts shall be maintained in good repair and free from obstructions. Roof water shall not be discharged in a manner that creates a public nuisance. BARRY STRATTON-09/13/2022 @ 12:47 304.12 Handrails and guards. Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition. Printed on 09/13;2022 e 12.53 Page 3 of 5 GENERAL NOTES BARRY STRATTON-09/13/2022 @ 12:48 304.13 Window,skylight and door frames. Every window,skylight,door and frame shall be kept in sound condition,good repair and weather tight. BARRY STRATTON-09/13/2022 @ 12:48 304.14 Insect screens.During the period from[DATE]to[DATE],every door,window and other outside opening required for ventilation of habitable rooms,food preparation areas,food service areas or any areas where products to be included or utilized in food for human consumption are processed, manufactured,packaged or stored shall be supplied with approved tightly fitting screens of minimum 16 mesh per inch(16 mesh per 25 mm),and every screen door used for insect control shall have a self-closing device in good working condition. BARRY STRATTON-09/13/2022 @ 12:48 304.18 Building security. Doors,windows or hatchways for dwelling units, room units or housekeeping units shall be provided with devices designed to provide security for the occupants and property within. BARRY STRATTON-09/13/2022 @ 12:49 305.3 Interior surfaces. Interior surfaces,including windows and doors,shall be maintained in good,clean and sanitary condition. Peeling,chipping,flaking or abraded paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected BARRY STRATTON-09/13/2022 @ 12:49 05.5 Handrails and guards. Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition. BARRY STRATTON-09/13/2022 @ 12:49 305.6 Interior doors.Every interior door shall fit reasonably well within its frame and shall be capable of being opened and closed by being properly and securely attached to jambs,headers or tracks as intended by the manufacturer of the attachment hardware. BARRY STRATTON-09/13/2022 @ 12:50 308.1 Accumulation of rubbish or garbage. Exterior property and premises,and the interior of every structure,shall be free from any accumulation of rubbish or garbage. Removed de-commissioned water heater from basement. BARRY STRATTON-09/13/2022 @ 12:51 404.7 Food preparation.Spaces to be occupied for food preparation purposes shall contain suitable space and equipment to store,prepare and serve foods in a sanitary manner.There shall be adequate facilities and services for the sanitary disposal of food wastes and refuse,including facilities for temporary storage. BARRY STRATTON-09/13/2022 @ 12:51 504.1 General.Plumbing fixtures shall be properly installed and maintained in working order,and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. Plumbing fixtures shall be maintained in a safe,sanitary and functional condition P-anted on 09/13/2022 2 12:53 Page 4 of 5 • GENERAL NOTES BARRY STRATTON-09/13/2022 @ 12:51 605.1 Installation. Electrical equipment,wiring and appliances shall be properly installed and maintained in a safe and approved manner BARRY STRATTON-09/13/2022 @ 12:52 505.4 Water heating facilities.Water heating facilities shall be properly installed, maintained and capable of providing an adequate amount of water to be drawn at every required sink, lavatory, bathtub,shower and laundry facility at a temperature not less than 110°F(43°C).A gas-burning water heater shall not be located in any bathroom,toilet room, bedroom or other occupied room normally kept closed, unless adequate combustion air is provided.An approved combination temperature and pressure-relief valve and relief valve discharge pipe shall be properly installed and maintained on water heaters. BARRY STRATTON-09/13/2022 @ 12:52 607.1 General. Duct systems shall be maintained free of obstructions and shall he capable of performing the required function. REINSPECTION DATE 10/13/2022 CONTACT SIGNATURE Matt Delagarelle Signed on:09/13/2022 @ 12:52 INSPECTOR SIGNATURE BARRY STRATTON Signed on:09/13/2022 @ 12:53 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Printed or,09/13/2022.a 12:53 Page 5of5 INVOICE DATE DUE DATE INVOICE# TOTAL DUE hAi\`'Jig. /Ii�11�� , NIP; 10/17/2022 11/20/2022 2023-0002 0299 $150.00 °lerloo ‘° Customer#: 23701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable MJ WATERLOO LLC 715 Mulberry St 3130 FINLEY RD STE 510 A WATERLOO, IA 50703 DOWNERS GROVE,IL 60515 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 212 REED ST- 9-13-22 FOR BILLING INQUIRY: (319)291-4323 L Description Total Price REINSPECTION FEE 2ND $150.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23701 10/17/2022 11/20/2022 2023-00020299 $150.00 Less Prepayment $0.00 Total Due—* $150.00 City of Waterloo WATERLOO FIRE RESCUE �,�„_INSPECTION REPORT 716\ t� M WATERLOO f LLC SINGLE FAMILY RENTAL,212 REED ST, WATERLOO IA 547(?3 DETAILS Inspection Date:09/13/2022 ( Inspection Type: Rental Inspection Inspection Number:8504 C Shift: N/A 1 Station: N/A Unit: N/A S Lead Inspector:BARRY STRATTON I Other Inspectors: N/A j Fee:$150.00 /vi STATUS CODE DESCRIPTION L 1018.1 -General Aisles and aisle accessways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section.Aisles or aisle accessways shall be provided from all occupied portions of the exit access that contain seats,tables,furnishings,displays and similar fixtures or equipment.The minimum width or required capacity of aisles shall be unobstructed. Exception: Encroachments complying with Section 1005.7. Inspector: BARRY STRATTON-Comments: FAIL 605.1 -Abatement of identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:BARRY STRATTON-Comments:GFCI in kitchen by sink need changed because it is burnt. GFCI by rear door trips out when checked and needs replaced. FAIL 906.1 -Where require° Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A,B, E,F, H,I, M, R-1,R-2, R-4 and S occupancies. Exception:In Group R-2 occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3. In areas where flammable or combustible liquids are stored, used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies, in accordance with Section 3315.1.5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories,computer rooms and generator rooms, where required by the fire code official. Inspector: BARRY STRATTON-Comments: FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector: BARRY STRATTON-Comments:Smoke detectors need installed to meet code requirements. main level has no smoke detector. ?Tinted on 09t13/2022 f, _— Page 1 of 3 STATUS CODE DESCRIPTION FAIL R3-Unfit for Human is the structure found to be fit for human occupancy according to the code?(IPMC Occupancy 118.1. ) Inspector:BARRY STRATTON-Comments:Potential for lead exposure from damaged material in dining room. FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector: BARRY STRATTON-Comments:Ceiling in dining room has fallen and needs all removed and replaced. Peeling paint needs corrected.Wall in stair way has water damage and large cracks from water damage. Remove all damaged material and replace. Find water leak and correct. Drain in basement is backed up and need corrected. Egress path blocked at side door. FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F?(IPMC 602.2) Inspector: BARRY STRATTON-Comments:Need covers on all registers. GENERAL NOTES BARRY STRATTON-09/13/2022 @ 10:03 305.1 General.The interior of a structure and equipment therein shall be maintained in good repair, structurally sound and in a sanitary condition. Occupants shall keep that part of the structure that they occupy or control in a clean and sanitary condition. Every owner of a structure containing a rooming house, housekeeping units,a hotel,a dormitory,two or more dwelling units or two or more nonresidential occupancies, shall maintain,in a clean and sanitary condition,the shared or public areas of the structure and exterior property. BARRY STRATTON-O9/13/2022 @ 10:03 305.3 Interior surfaces. Interior surfaces,including windows and doors,shall be maintained in good,clean and sanitary condition.Peeling,chipping,flaking or abraded paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected BARRY STRATTON-09/13/2022 @ 10:03 506.1 General. Plumbing fixtures shall be properly connected to either a public sewer system or to an approved private sewage disposal system. BARRY STRATTON-09/13/2022 @ 10:03 506.2 Maintenance. Every plumbing stack,vent,waste and sewer line shall function properly and be kept free from obstructions, leaks and defects.Drain in basement is backed up and not draining. Open clean out in basement Page 2 of 3 REINSPECTION DATE 10/12/2022 CONTACT SIGNATURE EPM Iowa -(i\AkL Signed on:09/13/2022 @ 10:04 INSPECTOR SIGNATURE BARRY STRATTON Signed on:09/13/2022 @ 10:04 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barty.stratton@waterloo-ia.org (319)231-9147 Printed on 09/13/2022(g.7 10_04 Page 3 of 3 1 � tz% ATE LOO FIRE RESCUE \ (\-\\cjiva-l' s .ill" oC INSPECTION REPORTNe.%00A 65 CONGER ST, WATERLOO iA 5070.3 DETAILS Inspection Date:08/15/2022 j Inspection Type: Rental Inspection I Inspection Number:8345 ' Shift: N/A Station: N/A 4Th, Unit: N/A Lead Inspector: BARRY STRATTON I Other Inspectors: N/A I Fee:$150.00 • f STATUS CODE DESCRIPTION 1010.1.9-Door operations Except as specifically permitted by this section,egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector:BARRY STRATTON-Comments:Unit#202 entrance door and North Fire Door FAIL 1013.5-Internally illuminated Electrically powered,self-luminous and photoluminescent exit signs shall be listed exit signs and labeled in accordance with UL 924 and shall be installed in accordance with the manufacturer's instructions and Section 604. Exit signs shall be illuminated at all times. Inspector: BARRY STRATTON-Comments: Exit sign still hanging from ceiling by wires. FAiL 1018.1 -General Aisles and aisle accessways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section.Aisles or aisle accessways shall be provided from all occupied portions of the exit access that contain seats,tables,furnishings,displays and similar fixtures or equipment.The minimum width or required capacity of aisles shall be unobstructed. Exception: Encroachments complying with Section 1005.7. Inspector:BARRY STRATTON-Comments: FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON-Comments:Lights hanging by wires and lights need globes. P-ntec Page 1 of 3 STATUS CODE DESCRIPTION FAIL 703.2- Opening protectives Opening protectives shall be maintained in an operative condition in accordance with NFPA 80.Where allowed by the fire code official,the application of field-applied labels associated with the maintenance of opening protectives shall follow the requirements of the approved third-party certification organization accredited for listing the opening protective. Fire doors and smoke barrier doors shall not be blocked or obstructed,or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged. Fire door assemblies shall not be modified. Inspector: BARRY STRATTON-Comments:Hardware on North fire door does not work at intended. Handle depressed does not let door open. Door still not corrected. FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector: BARRY STRATTON-Comments: FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector: BARRY STRATTON-Comments: FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may include boilers, heating equipment,elevator, moving stairways,electrical wiring,and flammable liquid containers.(IPMC 108.1.2) Inspector: BARRY STRATTON-Comments: Furnace and kitchen counter/sink. FAIL R3-Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPMC Occupancy 108.1.3) Inspector: BARRY STRATTON-Comments: Unit#202 FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector: BARRY STRATTON-Comments:Unsanitary conditions exist in unit#202. Kitchen counter top and sink is laying on kitchen floor. Entrance door is broken and needs replaced. Hardware on door is also broken. Fire Door hardware on North Fire Door is not working as designed. Door on bathtub clean out is not attached to wall. Peeling and abraded paint.Wall in bathroom has water damage. Doors and trim missing in apartment. P,inieo on 08/15/202:_ 2:49 Page 2 of 3 STATUS CODE DESCRIPTION FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions Inspector: BARRY STRATTON-Comments:Mold FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F?(IPMC 602.2) Inspector: BARRY STRATTON-Comments:Furnace filter needs replaced and vents need cleaned. FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition?(IPMC 603.1) Inspector: BARRY STRATTON-Comments: Bath fan need cleaned. REINSPECTION DATE 09/19/2022 CONTACT SIGNATURE John Foley `- Signed on:08/15/2022 @ 12:48 INSPECTOR SIGNATURE BARRY STRATTON Signed on:08/15/2022 @ 12:48 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia,org (319)231-9147 Page 3 of 3