City of Waterloo
WATERLOO FIRE RESCUE
INSPECTION REPORT ►
PHILLIP HILD SINGLE FAMILY RENTAL,5O1 MAGNOLIA PIS', WATERLOO IA 50701
DETAILS
Inspection Date:10/12/2022 j Inspection Type:Rental Inspection j Inspection Number:8500 Shift: N/A j Station: N/A
Unit: N/A j Lead Inspector:BARRY STRATTON j Other Inspectors: N/A j Fee:$50.00
751—,,
/e.41/14 ;14.5)41
STATUS CODE DESCRIPTION
FAIL 1031.7-Emergency escape Required emergency escape and rescue openings shall be maintained in accordance
and rescue openings with the code in effect at the time of construction,and the following: Required
emergency escape and rescue openings shall be operational from the inside of the
room without the use of keys or tools. Bars,grilles,grates or similar devices are
allowed to be placed over emergency escape and rescue openings provided the
minimum net clear opening size complies with the code that was in effect at the time
of construction and such devices shall be releasable or removable from the inside
without the use of a key,tool or force greater than that which is required for normal
operation of the emergency escape and rescue opening.
Inspector: BARRY STRATTON-Comments:Egress window well needs cleaned out.
Egress window screen will not move in the window track stopping exit through
window in event of a fire.
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector:BARRY STRATTON-Comments:Electrical system is not grounded.Ground
wire not connected.GFCI in bathroom will not trip.Globes needed on all light fixtures.
Cover in bathroom above door not secure.
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1.In new
and existing Group A, B, E, F, H, I, M,R-1,R-2, R-4 and S occupancies. Exception: In
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm)
of commercial cooking equipment.3. In areas where flammable or combustible
liquids are stored, used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas,
including but not limited to laboratories, computer rooms and generator rooms,
where required by the fire code official.
Inspector:BARRY STRATTON-Comments:
Pr ntec on i / 2i2O22 13:45
Page 1 of 4
STATUS CODE DESCRIPTION
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector: BARRY STRATTON-Comments:
FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector:BARRY STRATTON-Comments:
FAIL R1 - Unsafe Structures Is the structure found to be dangerous to the life, health, property or safety of either
the public or occupants of the structure?(IPMC 108.1.1)
Inspector: BARRY STRATTON-Comments:Bats
FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector: BARRY STRATTON-Comments:Bats in house,kitchen cabinets doors do
not open. Fabric on basement bedroom ceiling not fire rated and needs removed.
FAIL R6.A.- Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector:BARRY STRATTON-Comments:Bats
FAIL R6.C.-Mechanical Egiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector:BARRY STRATTON-Comments:Water heater installed with out permits and
inspections.Supply lines not installed to meet code requirements.Water heater is
also missing a discharge tube.Still not permits obtained.
GENERAL NOTES
BARRY STRATTON-10/12/2022 @ 13:29 309.1 Infestation.Structures shall be kept free from insect and rodent infestation.
Structures in which insects or rodents are found shall be promptly exterminated by
approved processes that will not be injurious to human health.After pest elimination,
proper precautions shall be taken to prevent reinfestation.
Printed or:10/12r2022 t 13:4.6
Page 2 of 4
GENERAL NOTES
BARRY STRATTON-10/12/2022 @ 13:29 302.5 Rodent harborage.Structures and exterior property shall be kept free from
rodent harborage and infestation.Where rodents are found,they shall be promptly
exterminated by approved processes that will not be injurious to human health.After
pest elimination,proper precautions shall be taken to eliminate rodent harborage and
prevent reinfestation
BARRY STRATTON-10/12/2022 @ 13:29 603.1 Mechanical equipment and appliances. Mechanical equipment,appliances,
fireplaces,solid fuel-burning appliances,cooking appliances and water heating
appliances shall be properly installed and maintained in a safe working condition,and
shall be capable of performing the intended function.
BARRY STRATTON-10/12/2022 @ 13:30 605.1 Installation. Electrical equipment,wiring and appliances shall be properly
installed and maintained in a safe and approved manner.
BARRY STRATTON-10/12/2022 @ 13:30 702.1 General.A safe,continuous and unobstructed path of travel shall be provided
from any point in a building or structure to the public way. Means of egress shall
comply with the International Fire Code.
BARRY STRATTON-10/12/2022 @ 13:45 New tenants no re-inspections done.
REINSPECTION DATE
11/10/2022
CONTACT SIGNATURE
Phillip Hild
Signed on:10/12/2022 @ 13:45
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:10/12/2022 @ 13:45
Printed on 10,12,2022 13:46