RENTAL INSPECTION - 1200 ACKERMANT ST- 3-15-23 FOR BILLING INQUIRY: (319)291-4323
[Description I Total Price
REINSPECTION FEE 2ND $150.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
23117 04/20/2023 05/25/2023 2023-00020381 $150.00
Less Prepayment $0.00
Total Due $150.00
City of Waterloo
R !
WATERLOO FIRE RE
SCUE .eli °°
INSPECTION REPORT D., .
MALBEC PROPERTIES LLC SINGLE FAMILY RENTAL, 1200 ACKERMANT ST, WATERLOO IA *4
S0703
DETAILS
Inspection Date:03/15/2023 I Inspection Type: Rental Inspection ( Inspection Number:9659 y Shift: N/A I tation: N/A I
Unit: N/A 1 Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$150.00 tit t 05.
a
�� Its
STATUS CODE DESCRIPTION
FAIL 1010.1.9-Door operations Except as specifically permitted by this section,egress doors shall he readily
openable from the egress side without the use of a key or special knowledge or
effort.
Inspector: BARRY STRATTON-Comments:Jambs broken and not weather tight.
FAIL 1031.7-Emergency escape Required emergency escape and rescue openings shall be maintained in accordance
and rescue openings with the code in effect at the time of construction,and the following: Required
emergency escape and rescue openings shall be operational from the inside of the
room without the use of keys or tools. Bars,grilles,grates or similar devices are
allowed to be placed over emergency escape and rescue openings provided the
minimum net clear opening size complies with the code that was in effect at the time
of construction and such devices shall be releasable or removable from the inside
without the use of a key,tool or force greater than that which is required for normal
operation of the emergency escape and rescue opening.
Inspector: BARRY STRATTON-Comments:Windows
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRY STRATTON-Comments:Light as the bottom of basement stairs
hanging from ceiling. Multi adapters in basement.GFCI outlet in kitchen not working.
GFCI outlet in kitchen not grounded. Exposed wires in box at base of basement stairs.
Printed an 03.15,2023(f 1017
Page 1 of 4 •
•
STATUS CODE DESCRI►TION
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new
and existing Group A,B,E, F, H, I, M, R-1,R-2, R-4 and S occupancies. Exception: In
Group R-2 occupancies,portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 min)
of commercial cooking equipment.3. In areas where flammable or combustible
liquids are stored,used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas,
including but not limited to laboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector: BARRY STRATTON-Comments:Will need updated fire extinguisher in unit.
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector: BARRY STRATTON-Comments:Smoke detectors missing and not working.
Smoke detectors hanging by the wires
FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector: BARRY STRATTON-Comments: Need CO detectors in vicinity of any
bedroom.
FAIL R3-Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPMC
Occupancy 108.1.3)
Inspector: BARRY STRATTON-Comments:Mold
FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector: BARRY STRATTON-Comments:Bedroom ceiling falling in. Peeling paint
throughout house,mold growing on basement walls.Material that has been
damaged by water needs removed and replaced. Egress path blocked by front
entrance. Bath door jamb needs replaced.Flooring damage and needs replaced.
Missing thresholds throughout. Basement handrail not attached, Egress window has
no crank. Back door jamb broken and not weather tight.Windows broken and do not
open and close. Register covers not attached to vents.Upstairs tub not working and
faucet is broken and water continues to run.All peeling and abraded paint will need
corrected. Sewage back up in basement. Mold still present on walls.
Printed on 03/15;2023 Cd 10:117
Page 2 of 4
STATUS CODE DESCRIPTION
FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector:BARRY STRATTON-Comments:Mold
FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room
temperature of 68F?(IPMC 602.2)
Inspector:BARRY STRATTON-Comments:Insulated duct to furnace has holes in duct.
Register covers
FAIL R6.C.-Mechanical Egiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector: BARRY STRATTON-Comments:Washing machine does not have drain
stack
GENERAL NOTES
BARRY STRATTON-03/15/2023 @ 10:15 504.1 General.Plumbing fixtures shall be properly installed and maintained in working
order,and shall be kept free from obstructions,leaks and defects and be capable of
performing the function for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe,sanitary and functional condition.
BARRY STRATTON-03/15/2023 @ 10:15 504.3 Plumbing system hazards.Where it is found that a plumbing system in a
structure constitutes a hazard to the occupants or the structure by reason of
inadequate service inadequate venting, cross connection, backsiphonage, improper
installation,deterioration or damage or for similar reasons,the code official shall
require the defects to be corrected to eliminate the hazard.
BARRY STRATTON-03/15/2023 @ 10:15 506.2 Maintenance.Every plumbing stack,vent,waste and sewer line shall function
properly and be kept free from obstructions, leaks and defects.Sanitary line is
collapsed
REINSPECT/ON DATE
04/12/2023
Printed on 03/15/2023 t^c 10 17
Page 3 of 4
CONTACT SIGNATURE
Malbec Properties LLC
Signed on:03/15/2023 @ 10:16
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:03/15/2023 @ 10:16