INSPECTION REPORT
PARADIGM INVESTMENTS&&C SINGLE FAMILY DWELLING,423 GALLOWAY CT, WATERLOO 1A
S0701
DETAILS
Inspection|nspection Date: 04/10/2023 \ inspection Type: Rental inspection I Inspection Number:9883 | Shift: N/A \ Station: N/A �
Unit: N/A \ Lead inspector: BARRY STRATTON | Other Inspectors: N/A | Fee:$150.00
STATUS CODE DESCRIPTION
FAIL 1031.7 Emergency escape Required emergency escape and rescue openings shall be maintained in accordance
and rescue openings with the code in effect at the time of construction,and the following: Required
emergency escape and rescue openings shall be operational from the inside of the
room without the use of keys or tools. Bars,grilles,grates or similar devices are
allowed to be placed over emergency escape and rescue openings provided the
minimum net clear opening size complies with the code that was in effect at the time
of construction and such devices shall be releasable or removable from the inside
without the use of key'tool or force greater than that which is required for normal
operation of the emergency escape and rescue opening.
Inspector: BARRv STRATTON [onnmenzs:Windows. Permit has been obtained but no
inspections have been scheduled for the windows that were installed.
FAIL 906.1 Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new
and existing Group A, B' E' F. H'|, rN'n'1' R'2. R'4and S occupancies. Exception: In
Group R'2 occupancies, pot-table fire extinguishers shall be required only in locations
specified in items Z through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1'A:1O'B:C.2.Within 30 feet(9144 mm)
of commercial cooking equipment.3. /n areas where flammable or combustible
liquids are scored' used or dispensed.4. On each floor of structures under
construction, except Group R'3 occupancies'in accordance with Section 3315.1. 5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas'
including but not limited to laboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector: BARRv STRATTON Comments: None
FAIL 907.2.11 Sin�|e'and Listed single-and multiple-station smoke alarms complying with ULZ17shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 987.2.11.6 and NFPA72.
alarms
Inspector:B^RRv STRATTOw Comments:None
:,�z» ,a,sa
Page of
STATUS CODE DESCRIPTION
FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector: BARRY STRATTON-Comments: None
FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair, structurally sound,and in a sanitary condition?(IPMC 305)
Inspector: BARRY STRATTON-Comments: None
FAIL R6.C.-Mechanical Egiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector: BARRY STRATTON-Comments:Water heater that was installed still has no
permits or inspections.
GENERAL NOTES
BARRY STRATTON-04/10/2023 @ 12:47 9-7-4 9-7-5 Rental Registration is still needed for listed address 2023. Rental unit in 2022
also was not registered.
BARRY STRATTON-04/10/2023 @ 12:48 9-4-6&9-4-8:Permits required for new water heater and inspections required for the
installed by licensed contractor.
REINSPECTION DATE
05/08/2023
CONTACT SIGNATURE
Caliber Group
Signed on:04/10/2023 @ 12:49
INSPECTOR SIGNATURE
BARRY STRATTON Signed on:on:04/10/2023 @ 12:49
P-rted on O4'1 ;2023 is 12:50
Page 2 of 3