Loading...
HomeMy WebLinkAbout933 KINGSLEY INVOICE DATE DUE DATE INVOICE# TOTAL DUE I � -.k•% 04/20/2023 05/25/2023 2023-00020387 $50.00 °rerloo Customer#: 4967 Please Make Check Payable and Remit To: City of Waterloo A TTN: City Clerk/Accounts Receivable MICHAEL TAYLOR 715 Mulberry St 322 RAE DR WATERLOO, IA 50703 EVANSDALE, IA 50707 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION- 933 KINGSLEY- 3-14-23 FOR BILLING INQUIRY: (319)291-4323 Description Total Price, REINSPECTION FEE 1ST $50.00 / v /5 `ii CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 4967 04/20/2023 05/25/2023 2023-00020387 $50.00 Less Prepayment $0.00 Total Due $50.00 City of Waterloo WATERLOO FIRE RESCUE (i) otatzy INSPECTION REPORT 0 MICHAEL TAYLOR SINGLE FAMILY RENTAL,933 KINGSLEYAYE, WATERLOO IA 50701 DETAILS Inspection Date:03/14/2023 Inspection Type: Rental Inspection I Inspection Number:9658 I Shift: N/A I Station: N/A I Unit: N/A I Lead Inspector: BARRY STRATTON I Other Inspectors: N/A I Fee:$50.00 / 1,/. 710 STATUS CODE DESCRIPTION FAIL 1031.1 -General. Emergency escape and rescue openings shall comply with the requirements of this section. Inspector: BARRY STRATTON-Comments:No egress window in basement. FAIL 603.2-Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official. hazards. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Inspector: BARRY STRATTON-Comments: Light missing in living room,(possible electrical fire in fixture), missing switch in living room,ground lug on waterline in basement needs secured,extension cords in use need removed, missing covers on electric boxes in basement,light fixture not attached to box in basement, bedroom outlet pulling out of wall. P anted or,03 14/2023 4 09:53 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 906.1 -Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.►n new and existing Group A, B,E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exceptions: 1.In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.In Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C.3. In storage areas of Group S occupancies where forklift, powered industrial truck or powered cart operators are the primary occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in accordance with all of the following:3.1. Use of vehicle-mounted extinguishers shall be approved by the fire code official. 3.2. Each vehicle shall be equipped with a 10- pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not less than two spare extinguishers of equal or greater rating shall be available on-site to replace a discharged extinguisher.3.4.Vehicle operators shall be trained in the proper operation,use and inspection of extinguishers.3.5. Inspections of vehicle- mounted extinguishers shall be performed daily.2.Within 30 feet(9144 min)distance of travel from commercial cooking equipment and from domestic cooking equipment in Group I-1; 1-2,Condition 1;and R-2 college dormitory occupancies.3.In areas where flammable or combustible liquids are stored,used or dispensed.4.On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3316.1.5.Where required by the sections indicated in Table 906.1.6.Special- hazard areas, including but not limited to laboratories,computer rooms and generator rooms,where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Inspector: BARRY STRATTON-Comments: FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.7 and NFPA 72. alarms. Inspector: BARRY STRATTON-Comments:Detectors all need to be in working condition.Need detector in basement. FAIL 915.1 -General. Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6. Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector: BARRY STRATTON-Comments:Need to be in working condition FAIL R4- Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This includes grading and drainage,sidewalks and driveways,weeds,and pest infestations.(IPMC 302) Inspector:BARRY STRATTON-Comments:Ground heaving from water. Possible broken service line. Front steps tipping out away from house. Sidewalk is heaved. Printed on 93/14/2023`c 09:53 Page 2 of 3 3 L STATUS CODE DESCRIPTION FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector:BARRY STRATTON-Comments:Toilet needs re-set on floor with new wax ring,tub clean out door in bedroom needs approved door. Dishwasher leaking,no egress window in basement,(bed in basement), Foundation is leaking,drain in basement does not drain,shower valve in basement leaks, High water bills,water service is leaking. Sewer pipe in basement leaking. Basement window by laundry leak when raining. FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition?(1PMC 603.1) Inspector: BARRY STRATTON-Comments:Intermittent hot water. REINSPECTION DATE 04/11/2023 CONTACT SIGNATURE Michael Taylor Signed on:03/14/2023 @ 09:57 INSPECTOR SIGNATURE BARRY STRATTON Signed on:03/14/2023 @ 09:57 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Parted on 03:/'4 20_23,^c 09:53 Page 3 of 3