RENTAL INSPECTION- 2501 LAFAYETTE ST- 3-15-23 FOR BILLING INQUIRY: (319)291-4323
L Description 1 Total Price]
REINSPECTION FEE 1ST $50.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
12490 04/20/2023 05/25/2023 2023-00020388 $50.00
Less Prepayment $0.00
Total Due—> $50.00
City of Waterloo
WATERLOO FIRE RESCUE 1/.3Y 9 0
.:y
INSPECTION REPORT11:
METRO INVESTMENTS LLC SINGLE FAMILY RENTAL,2501 LAFAYETTE ST, WATERLOO IA 50703
DETAILS
Inspection Date:03/15/2023 Inspection Type: Rental Inspection I Inspection Number:9596 I Shift: N/A Station: N/A I
Unit: N/A I Lead Inspector:BARRY STRATTON Other Inspectors: N/A I Fee:$50.00
fr 141 tt.' -Pis(
STATUS CODE DESCRIPTION
FAIL 603.2-Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions
conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official.
hazards. Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes Conditions that constitute an electrical shock or fire hazard
shall be abated not be used.
Inspector: BARRY STRATTON-Comments:Missing outlet covers,multi adapters in
use,outlets not working and blowing breakers,GFCI main level bathroom not
working.
FAIL 906.1 -Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.1n new
and existing Group A, B, E,F, H, I, M, R-1,R-2,R-4 and S occupancies. Exceptions:1.1n
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A:10-B:C.2.ln Group E occupancies,
portable fire extinguishers shall be required only in locations specified in Items 2
through 6 where each classroom is provided with a portable fire extinguisher having
a minimum rating of 2-A:20-B:C.3. In storage areas of Group S occupancies where
forklift,powered industrial truck or powered cart operators are the primary
occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in
accordance with all of the following:3.1.Use of vehicle-mounted extinguishers shall
be approved by the fire code official.3.2. Each vehicle shall be equipped with a 10-
pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket
approved by the extinguisher manufacturer or the fire code official for vehicular use.
3.3. Not less than two spare extinguishers of equal or greater rating shall be available
on-site to replace a discharged extinguisher.3.4.Vehicle operators shall be trained in
the proper operation,use and inspection of extinguishers.3.5.Inspections of vehicle-
mounted extinguishers shall be performed daily.2.Within 30 feet(9144 mm)distance
of travel from commercial cooking equipment and from domestic cooking equipment
in Group 1-1; 1-2,Condition 1;and R-2 college dormitory occupancies.3.In areas where
flammable or combustible liquids are stored, used or dispensed.4.On each floor of
structures under construction, except Group R-3 occupancies,in accordance with
Section 3316.1.5.Where required by the sections indicated in Table 906.1.6.Special-
hazard areas,including but not limited to laboratories,computer rooms and
generator rooms,where required by the fire code official. Exception:Portable fire
extinguishers are not required at normally unmanned Group U occupancy buildings
or structures where a portable fire extinguisher suitable to the hazard of the location
is provided on the vehicle of visiting personnel.
Inspector:BARRY STRATTON-Comments:
Printed on 03/15/2023`y 09:47
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.7 and NFPA 72.
alarms.
Inspector:BARRY STRATTON-Comments:Smoke detectors needed in all bedrooms,
basement and outside bedroroms.
FAIL 915.1 -General. Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector:BARRY STRATTON-Comments:Need CO detectors in vicinity of any room
used as bedroom.
FAIL R4-Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This
includes grading and drainage,sidewalks and driveways,weeds,and pest
infestations.(IPMC 302)
Inspector:BARRY STRATTON-Comments:Ground disturbed by sewer repair.
FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector: BARRY STRATTON-Comments:Basement mold,bathroom in basement
not working,handrails missing to basement, peeling paint in main level bathroom,
back door weatherization is needed,bugs,stove know missing,cabinets drawers
broken,face plates on cabinets broken,doors on bedrooms not in jambs.
FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector:BARRY STRATTON-Comments:Mold
FAIL R6.D.-Receptacles Every habitable space in a dwelling shall contain not less than two separate and
remote receptacle outlets. Every laundry area shall contain not less than one
grounding-type receptacle or a receptacle with a GFCI.Every bathroom shall contain
not less than one receptacle.Any new bathroom receptacle shall have GFCI
protection.All receptacles shall have the appropriate faceplate cover.(IPMC 605.2)
Inspector:BARRY STRATTON-Comments:Need outlet covers on all outlets.
GENERAL NOTES
Printed an 03/15/2023 09:47
Page 2 of 3
BARRY STRATTON-03/15/2023 @ 09:44 309.1 Infestation.Structures shall be kept free from insect and rodent infestation.
Structures in which insects or rodents are found shall be promptly exterminated by
approved processes that will not be injurious to human health.After pest elimination,
proper precautions shall be taken to prevent reinfestation.
BARRY STRATTON-03/15/2023 @ 09:44 304.13 Window,skylight and door frames. Every window,skylight,door and frame shall
be kept in sound condition,good repair and weather tight.
BARRY STRATTON-03/15/2023 @ 09:45 305.5 Handrails and guards. Every handrail and guard shall be firmly fastened and
capable of supporting normally imposed loads and shall be maintained in good
condition.
REINSP€CTIoN DATE
04/12/2023
CONTACT SIGNATURE
Metro Investments LLC £IMkL
Signed on:03/15/2023 @ 09:45
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:03/15/2023 @ 09:45