Loading...
HomeMy WebLinkAbout612 RHEY ST INVOICE DATE DUE DATE INVOICE# TOTAL DUE /hipjiFi\ 02/20/2023 03/25/2023 2023-00020369 $150.00 eterloo v Customer#: 23528 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable DJS PROPERTIES 715 Mulberry St 1732 PINEHURST LN WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION- 612 RHEY ST- 12-7-22 FOR BILLING INQUIRY: (319)291-4323 L Description I Total Price REINSPECTION FEE 2ND $150.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23528 02/20/2023 03/25/2023 2023-00020369 $150.00 Less Prepayment $0.00 Total Due $150.00 City of Waterloo pZER(cy: FIRE RESCUE WATERLOO , „, INSPECTION REPORT DJS PROPERTIES LLC 3 FAMILY CONVERSION, 612 RHEY ST, WATERLOO IA 30703 DETAILS Inspection Date: 12/07/2022 Inspection Type: Rental Inspection I Inspection Number:9118 ; Shift: N/A I Station: N/A Unit: N/A Lead Inspector:BARRY STRATTON l Other Inspectors: N/A j Fee:$150.00 gAr, STATUS CODE DESCRIPTION FAIL 1010.1.9-Door operations Except as specifically permitted by this section,egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON-Comments:Front door FAIL 1031.7-Emergency escape Required emergency escape and rescue openings shall be maintained in accordance and rescue openings with the code in effect at the time of construction,and the following:Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars,grilles,grates or similar devices are allowed to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of a key,tool or force greater than that which is required for normal operation of the emergency escape and rescue opening. Inspector: BARRY STRATTON-Comments:Window sills rotten FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON-Comments:Outlets not grounded and have tension strength issues. Outlets have grounding pins broken off in outlets. Have outlets replaced and grounding issues corrected.Globes needed on all light. Light in living room has exposed wires. printed on 12/07,2022 T 13:32 Page 1 of 4 • STATUS COOS DESCRIPTION FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A, B, E, F, H, I, M, R-1, R-2,R-4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3. In areas where flammable or combustible liquids are stored,used or dispensed.4. On each floor of structures under construction,except Group R-3 occupancies,in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Inspector: BARRY STRATTON-Comments: FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector:BARRY STRATTON-Comments:No smoke detectors installed in unit#1 FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector: BARRY STRATTON-Comments:CO detectors needed FAIL R5-Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and sanitary state?(IPMC 304) Inspector: BARRY STRATTON-Comments:Front porch has supports that are failing. Front stairs are rotten and need replaced.Holes in porch floor need corrected. Apartment door to# 1 needs replaced since door has been broken and split at lock sets FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector:BARRY STRATTON-Comments: Floors,carpet stained,floor has several dips from supports in basement failing. Holes in walls, rotten window sills in bedroom, screen damaged, register vents not in ducts. FAIL R6.B.- Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F?(IPMC 602.2) inspector: BARRY STRATTON-Comments: Register covers Printeo= 2/07t2022`, Page 2 of 4 GENERAL NOTES BARRY STRATTON-12/07/2022 @ 13:30 304.10 Stairways,decks,porches and balconies. Every exterior stairway,deck,porch and balcony,and all appurtenances attached thereto,shall be maintained structurally sound, in good repair,with proper anchorage and capable of supporting the imposed loads BARRY STRATTON-12/07/2022 @ 13:30 304.15 Doors. Exterior doors,door assemblies,operator systems if provided,and hardware shall be maintained in good condition. Locks at all entrances to dwelling units and sleeping units shall tightly secure the door. Locks on means of egress doors shall be in accordance with Section 702.3. BARRY STRATTON-12/07/2022 @ 13:30 304.13 Window,skylight and door frames. Every window,skylight,door and frame shall be kept in sound condition,good repair and weather tight. BARRY STRATTON-12/07/2022 @ 13:30 305.4 Stairs and walking surfaces.Every stair,ramp,landing,balcony,porch,deck or other walking surface shall be maintained in sound condition and good repair. BARRY STRATTON-12/07/2022 @ 13:31 304.4 Structural members.Structural members shall be maintained free from deterioration,and shall be capable of safely supporting the imposed dead and live loads BARRY STRATTON-12/07/2022 @ 13:31 305.3 Interior surfaces. Interior surfaces,including windows and doors,shall be maintained in good,clean and sanitary condition. Peeling,chipping,flaking or abraded paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected. BARRY STRATTON-12/07/2022 @ 13:31 604.3 Electrical system hazards.Where it is found that the electrical system in a structure constitutes a hazard to the occupants or the structure by reason of inadequate service, improper fusing, insufficient receptacle and lighting outlets, improper wiring or installation,deterioration or damage,or for similar reasons,the code official shall require the defects to be corrected to eliminate the hazard.Licensed contractor needed to make electrical corrections. REINSPECTION DATE 01/04/2023 Printed on't 2/07;202: Page 3of4 CONTACT SIGNATURE DJS Properties LLC ' Signed on:12/07/2022 @ 13:31 INSPECTOR SIGNATURE BARRY STRATTON Signed on:12/07/2022 @ 13:32 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Printed on 12/07/2022 i4 13.32 Page 4 of 4