RENTAL INSPECTION- 1738 FLOWER ST#2 - 1-10-23 FOR BILLING INQUIRY: (319)291-4323
L Description j Total Price
REINSPECTION FEE 3RD $250.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
10811 02/20/2023 03/25/2023 2023-00020375 $250.00
Less Prepayment $0.00
Total Due—> $250.00
City of Waterloo
WATERLOO FIRE RESCUE 't0"00
}
INSPECTION REPORT
DOMINIC TANGEN RENTAL$-PLED, 1738 FLOWER ST,WATERLOO lA 50701,
DETAILS
Inspection Date:01/10/2023 I Inspection Type: Rental Inspection Inspection Number:9312 I Shift: N/A I Station: N/A I
Unit: N/A j Lead Inspector:BARRY STRATTON I Other Inspectors: N/A i Fee:$250.00
0141/ 4/015,
STATUS CODE DESCRIPTION
FAIL 1013.3- Illumination Exit signs shall be internally or externally illuminated. Exception:Tactile signs required
by Section 1013.4 need not be provided with illumination.
Inspector: BARRY STRATTON-Comments:Egress/exit lights
FAIL 1025.5- Illumination Where photolurninescent exit path markings are installed,they shall be provided with
not less than 1 footcandle(11 lux)of illumination for not less than 60 minutes prior to
periods when the building is occupied and continuously during the building
occupancy.
Inspector: BARRY STRATTON-Comments:
FAIL 1031.2- Reliability Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector: BARRY STRATTON-Comments:Outlets missing and wire being scrapped
from building
FAI L 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRY STRATTON-Comments:
r nted on 011110/2023 4 10:33
Page 1 of 4
STATUS CODE DESCRIPTION
FAIL 703.2-Opening protectives Opening protectives shall be maintained in an operative condition in accordance with
NFPA 80.Where allowed by the fire code official,the application of field-applied labels
associated with the maintenance of opening protectives shall follow the
requirements of the approved third-party certification organization accredited for
listing the opening protective. Fire doors and smoke barrier doors shall not be
blocked or obstructed,or otherwise made inoperable. Fusible links shall be replaced
promptly whenever fused or damaged.Fire door assemblies shall not be modified.
Inspector: BARRY STRATTON-Comments:Alarm testing and maintenance has still not
been done.
FAIL 901.6-Inspection,testing and Fire detection,alarm,and extinguishing systems,mechanical smoke exhaust
maintenance systems,and smoke and heat vents shall be maintained in an operative condition at
all times,and shall be replaced or repaired where defective. Nonrequired fire
protection systems and equipment shall be inspected,tested and maintained or
removed.
Inspector:BARRY STRATTON-Comments:
FAIL 901.6.1 -Standards Fire protection systems shall be inspected,tested and maintained in accordance with
the referenced standards listed in Table.
Inspector:BARRY STRATTON-Comments:
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1.In new
and existing Group A,B, E, F, H,I, M,R-1, R-2, R-4 and S occupancies. Exception: In
Group R-2 occupancies,portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A:10-B:C.2.Within 30 feet(9144 mm)
of commercial cooking equipment.3.In areas where flammable or combustible
liquids are stored, used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies, in accordance with Section 3315.1.5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas,
including but not limited to laboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector: BARRY STRATTON-Comments:
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector:BARRY STRATTON-Comments:Detectors missing throughout building and
all apartments.
Printed on O1/10/2023«10:33
Page 2 of 4
STATUS CODE DESCRIPTION
FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may
include boilers,heating equipment,elevator,moving stairways,electrical wiring,and
flammable liquid containers.(IPMC 108.1.2)
Inspector: BARRY STRATTON-Comments:All units are uninhabitable. Building does
not meet fire safety and rental requirements.
FAIL R3-Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPMC
Occupancy 108.1.3)
Inspector: BARRY STRATTON-Comments:Apartments 1-8
FAIL R4- Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This
includes grading and drainage,sidewalks and driveways,weeds, and pest
infestations.(IPMC 302)
Inspector: BARRY STRATTON-Comments:Debris
FAIL R5-Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and
sanitary state?(IPMC 304)
Inspector: BARRY STRATTON-Comments:Windows,doors,electrical
FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector:BARRY STRATTON-Comments:All units 1-8 unfit to occupy
FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector: BARRY STRATTON-Comments:
FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room
temperature of 68F?(IPMC 602.2)
Inspector: BARRY STRATTON-Comments:
FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector: BARRY STRATTON-Comments:
Printed on < _---;c 10:33
Page 3 of 4
. .
GENERAL NOTES
BARRY STRATTON-01/10/2023 @ 10:32 9-7-4 9-7-5:2023 Rental Registration is needed
REINSPECTION DATE
02/09/2023
CONTACT SIGNATURE
Dominic Tangen
Signed on:01/10/2023 @ 10:32
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:01/10/2023 @ 10:32