RENTAL INSPECTION- 611 LINCOLN ST-2-15-23 FOR BILLING INQUIRY: (319)291-4323
[Description I Total Price
REINSPECTION FEE 3RD $250.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
24034 02/20/2023 03/25/2023 2023-00020377 $250.0
Less Prepayment $0.
Total Due -* $25C
City of Waterloo
J i �WATERLOO FIRE RESCUE
i'�� �rt'ERCQ�
; „,
INSPECTION REPORT .q �yp.
HEARTLAND RENTAL PROPERTIES LLC SING £FAMILY,611 UNCOLN ST, WATERLOO IA S0703 'AF gEPC
DETAILS lt\gat`1/44
t‘it‘
Inspection Date:12/21/2022 1 Inspection Type: Rental Inspection 1 Inspection Number:8434 Shift: N/A I Station: N/A
Unit: N/A Lead Inspector:BARRY STRATTON I Other Inspectors: N/A 1 Fee:$50.00
STATUS CODE DESCRIPTION
FAIL 1031.7-Emergency escape Required emergency escape and rescue openings shall be maintained in accordance
and rescue openings with the code in effect at the time of construction,and the following:Required
emergency escape and rescue openings shall be operational from the inside of the
room without the use of keys or tools. Bars,grilles,grates or similar devices are
allowed to be placed over emergency escape and rescue openings provided the
minimum net clear opening size complies with the code that was in effect at the time
of construction and such devices shall be releasable or removable from the inside
without the use of a key,tool or force greater than that which is required for normal
operation of the emergency escape and rescue opening.
Inspector:BARRY STRATTON-Comments:Brocken glass in windows.
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRY STRATTON-Comments:No permit for electric to new furnace.
Missing switch covers,bath light does not work.
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new
and existing Group A,B, E,F, H,I,M,R-1,R-2,R-4 and S occupancies. Exception:In
Group R-2 occupancies,portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A:10-B:C.2.Within 30 feet(9144 mm)
of commercial cooking equipment.3. In areas where flammable or combustible
liquids are stored, used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas,
including but not limited to laboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector:BARRY STRATTON-Comments:
Printed on 12,21,2022 '03:29
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector: BARRY STRATTON-Comments:Need smoke detectors in bedrooms,
outside bedrooms,and in basement.
FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector: BARRY STRATTON-Comments:Sink cabinet is wet and moldy. Drain backed
up in basement. Mice in basement.Smoke detectors and CO needed
FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room
temperature of 68F?(IPMC 602.2)
Inspector: BARRY STRATTON-Comments:New Goodman furnace installed no
permits/inspections.Get permits/inspections from HVAC inspector.
FAlt R6.C.- Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector: BARRY STRATTON-Comments:Water heater no permits/inspections. Bath
fan needs replace because it is not working.
REINSPECTION DATE
01/19/2023
CONTACT SIGNATURE
Tony Pitzenburger
Signed on:12/21/2022 @ 08:29 /\11\ \\\K_
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on: 12/21/2022 @ 08:29
Page 2 of 3
QUESTIONS ABOUT YOUR INSPECTION?
BARRY STRATTON
barry.stratton@waterloo-ia.org
(319)231-9147
P.-fnted on 12/21;2022 g 03:29
Page 3of3