WATERLOO FIRE RESCUEa`•fu
INSPECTION REPORT .44
HEARTLAND RENTAL PROPERTIES LLC SINGLE FAMILY, 611 LINCOLN ST, WATERLOO IA 50703
DETAILS
Inspection Date:02/15/2023 I Inspection Type: Rental Inspection I Inspection Number:9508 I Shift: N/A I Station: N/A
Unit: N/A I Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$250.00 ®%' J+�+ 4 STATUS CODE DESCRIPTION
FAIL 605.1 -Abatement of identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
inspector: BARRY STRATTON-Comments:No permit for electric to new furnace.
Missing switch covers,bath light does not work.
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1.In new
and existing Group A,B, E, F, H,I,M,R-1,R-2,R-4 and S occupancies. Exception: In
Group R-2 occupancies,portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A:10-B:C.2.Within 30 feet(9144 mm)
of commercial cooking equipment.3. In areas where flammable or combustible
liquids are stored,used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies, in accordance with Section 3315.1.5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas,
including but not limited to laboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector:BARRY STRATTON-Comments:
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector:BARRY STRATTON-Comments:Need smoke detectors in bedrooms,
outside bedrooms,and in basement.
FAIL R6-interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector: BARRY STRATTON-Comments:Sink cabinet is wet and moldy.Drain backed
up in basement.Mice in basement.Smoke detectors and CO needed
FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room
temperature of 68F?(iPMC 602.2)
P-ined on 02r'5,2023 i_099.11
Page 1 of 2
STATUS CODE DESCRIPTION
Inspector: BARRY STRATTON-Comments:New Goodman furnace installed no
permits/inspections.Get permits/inspections from HVAC inspector.
FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector:BARRY STRATTON-Comments:Water heater no permits/inspections.
REINSPECTION DATE
03/14/2023