WATERLOO FIRE RESCUE
g\-4-11
INSPECTION REPORT
WATERLOO INVESTMENT GROUP LLC 8 FLEX,3863 PAIGE DR,WATERLOO IA 50702
DETAILS
Inspection Date:02/16/2023 I Inspection Type: Rental Inspection ! Inspection Number:9456 } Shift: N/A I Station: N/A I
Unit: N/A Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$50.00/ f4J4)775
4
STATUS CODE DESCRIPTION
FAIL 1010.1.9-Door operations Except as specifically permitted by this section,egress doors shall be readily
operable from the egress side without the use of a key or special knowledge or
effort.
Inspector: BARRY STRATTON-Comments:Fire doors still held in the open position.
FAIL 1031.7-Emergency escape Required emergency escape and rescue openings shall be maintained in accordance
and rescue openings with the code in effect at the time of construction,and the following: Required
emergency escape and rescue openings shall be operational from the inside of the
room without the use of keys or tools.Bars,grilles,grates or similar devices are
allowed to be placed over emergency escape and rescue openings provided the
minimum net clear opening size complies with the code that was in effect at the time
of construction and such devices shall be releasable or removable from the inside
without the use of a key,tool or force greater than that which is required for normal
operation of the emergency escape and rescue opening.
Inspector: BARRY STRATTON-Comments:Screens missing on windows in common
hallways.
FAIL 703.2-Opening protectives Opening protectives shall be maintained in an operative condition in accordance with
NFPA 80.Where allowed by the fire code official,the application of field-applied labels
associated with the maintenance of opening protectives shall follow the
requirements of the approved third-party certification organization accredited for
listing the opening protective. Fire doors and smoke barrier doors shall not be
blocked or obstructed,or otherwise made inoperable. Fusible links shall be replaced
promptly whenever fused or damaged.Fire door assemblies shall not be modified.
Inspector:BARRY STRATTON-Comments:Fire doors held in the open position.
FAIL 901.6-Inspection,testing and Fire detection,alarm,and extinguishing systems,mechanical smoke exhaust
maintenance systems,and smoke and heat vents shall be maintained in an operative condition at
all times,and shall be replaced or repaired where defective. Nonrequired fire
protection systems and equipment shall be inspected,tested and maintained or
removed.
Inspector:BARRY STRATTON-Comments:Alarm needs maintenance and testing.
P anted on 02,1 4,2023 tc 12:44
Page 1 of 3
ta.
STATUS CODE DESCRIPTION
FAIL 901.6.1 -Standards Fire protection systems shall be inspected,tested and maintained in accordance with
the referenced standards listed in Table.
Inspector:BARRY STRATTON-Comments:
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1.In new
and existing Group A,B, E, F, H,I,M,R-1, R-2, R-4 and S occupancies. Exception: In
Group R-2 occupancies,portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A:10-B:C.2.Within 30 feet(9144 mm)
of commercial cooking equipment.3. In areas where flammable or combustible
liquids are stored,used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies,in accordance with Section 3315.1.5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas,
including but not limited to laboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector:BARRY STRATTON-Comments:
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector:BARRY STRATTON-Comments:Missing in common hallways and some
beeping.
FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector:BARRY STRATTON-Comments:Common hallways missing detectors.
FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector:BARRY STRATTON-Comments:Fan cover missing in laundry area.
GENERAL NOTES
BARRY STRATTON-02/16/2023 @ 12:43 All corrections still have not been done.
REINSPECTION DATE
03/16/2023
Primed an 0211512023 t 12144
Page 2 of 3