HomeMy WebLinkAbout210 INDEPENDENCE AVE (2) INVOICE DATE DUE DATE INVOICE# TOTAL DUE
/11r, :;+ fic 1'4 02/20/2023 03/25/2023 2023-00020380 $250.00
°terloo �o
Customer#: 23001 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
QUALITY CONCRETE CONTRUCTION(RENTAL) 715 Mulberry St
1930 HAWTHORNE AVE#1 WATERLOO, IA 50703
WATERLOO, IA 50702
Amount Enclosed.
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
RENTAL INSPECTION- 210 INDEPENDENCE AVE- 1-24-23 FOR BILLING INQUIRY: (319)291-4323
L Description I Total Price J
REINSPECTION FEE 3RD $250.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
23001 02/20/2023 03/25/2023 2023-00020380 $250.00
Less Prepayment $0.00
Total Due — $250.00
City of Waterloo
WATERLOO FIRE RESCUE
INSPECTION REPORT
QUALITY CONCRETE CONSTRUCTION MULTI UNIT COMPLEX,210 INDEPENDENCE AVE,
WATERLOO IA 50703 4400
DETAILS
Inspection Date:01/24/2023 I Inspection Type: Rental Inspection I Inspection Number:9398 I Shift: N/A I Station: N/A I
Unit: N/A j Lead Inspector: BARRY STRATTON I Other Inspectors: N/A j Fee:$250.00
ø
STATUS CODE DESCRIPTION
FAIL 1010.1.9-Door operations Except as specifically permitted by this section,egress doors shall be readily
openable from the egress side without the use of a key or special knowledge or
effort.
Inspector: BARRY STRATTON-Comments:
FAIL 1031.7-Emergency escape Required emergency escape and rescue openings shall be maintained in accordance
and rescue openings with the code in effect at the time of construction,and the following: Required
emergency escape and rescue openings shall be operational from the inside of the
room without the use of keys or tools. Bars,grilles,grates or similar devices are
allowed to be placed over emergency escape and rescue openings provided the
minimum net clear opening size complies with the code that was in effect at the time
of construction and such devices shall be releasable or removable from the inside
without the use of a key,tool or force greater than that which is required for normal
operation of the emergency escape and rescue opening.
Inspector: BARRY STRATTON-Comments:Windows need to open and close
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRY STRATTON-Comments:Globes missing on lights
FAIL 605.5- Extension cords Extension cords and flexible cords shall not be a substitute for permanent wiring.
Extension cords and flexible cords shall not be affixed to structures,extended
through walls,ceilings or floors,or under doors or floor coverings, nor shall such
cords be subject to environmental damage or physical impact. Extension cords shall
be used only with portable appliances.
Inspector: BARRY STRATTON-Comments:
P-rated or; 1U:3°
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new
and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exception: In
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm)
of commercial cooking equipment. 3. In areas where flammable or combustible
liquids are stored, used or dispensed.4. On each floor of structures under
construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas,
including but not limited to laboratories, computer rooms and generator rooms,
where required by the fire code official.
Inspector: BARRY STRATTON-Comments:
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector: BARRY STRATTON-Comments:Smoke detectors needed in all bedrooms,
outside all bedrooms,on all levels,and in basement.
FAiL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915. 6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector: BARRY STRATTON-Comments:CO detectors needed in vicinity of
bedrooms.
FAIL R4-Exterior Property Areas Is the exterior property area maintained in a clean,safe, and sanitary condition?This
includes grading and drainage,sidewalks and driveways,weeds, and pest
infestations.(IPMC 302)
Inspector: BARRY STRATTON-Comments:Junk and debris
FAIL R5- Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and
sanitary state?(IPMC 304)
Inspector: BARRY STRATTON-Comments:Handrails do not meet code front steps
and concrete steps on building need replaced.
FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound, and in a sanitary condition?(IPMC 305)
P,n.ea 24 _ 1._30
Page 2 of 3
STATUS CODE DESCRIPTION
Inspector:BARRY STRATTON-Comments: Kitchen&Dining room ceilings have water
damage. Remove all water damaged material and replace. Cockroaches need
exterminated. Kitchen floor needs replaced.Windows need to be capable of opening
and closing. Front door and screen door need repaired and be capable of closing and
latching.Toilet need re-set on bathroom floor. Stove needs replaced. Kids bedroom
ceiling has holes that need corrected. Need handrails on stairs to upstairs and
basement stairs.Glass all over inside apartment.
FAIL R6.C.- Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector: BARRY STRATTON-Comments:Water heater need discharge tube
installed.
GENERAL NOTES
BARRY STRATTON-01/24/2023 @ 10:29 9-7-4 9-7-5:2022&2023 Rental Registration is needed for all rental units.
REINSPECTION DATE
02/21/2023
CONTACT SIGNATURE
Joyce Wood EVA\
Signed on:01/24/2023 @ 10:29
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:01/24/2023 @ 10:29
QUESTIONS ABOUT YOUR INSPECTION?
BARRY STRATTON
barry.stratton@waterloo-ia.org
(319)231-9147
Page 3 of 3