HomeMy WebLinkAbout2715 ST FRANCIS DR INVOICE DATE DUE DATE INVOICE# TOTAL DUE
I
i�ii��\ IN�.iarlIFIrm, rige,t, 10/17/2022 11/20/2022 2023-00020260 $150.00
"ramt`'�,
;vs r.._.5 TP,."--...7
`Merl j ‘o
Customer#: 20879 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
UNIVERSAL ACCES MORT.MIDWEST 715 Mulberry St
P.O. BOX 29502 ECM 38146 WATERLOO, IA 50703
LAS VEGAS,NV 89126
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
RENTAL INSPECTION- 2715 ST FRANCIS DR- 7-27-22 FOR BILLING INQUIRY: (319)291-4323
Description I Total Price J
REINSPECTION FEE 2ND $150.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
20879 10/17/2022 11/20/2022 2023-00020260 $150.00
Less Prepayment $0.00
Total Due-- $150.00
City of Waterloo
WATERLOO RESCUE
���� � ����8����� Qrm��u� -
INSPECTION REPORT po ^'~~ .N//1DWOODTOWNHOUSES UN� �� � �N� � ���� ������ � �� ��D� OO 1A�K�2
/l
/ /"n�� /�'�0 V�w�' ��~~~~
oenu/�o ,~�
Inspection Date:07/Z7/2O22 1 Inspection Type: Rental Inspection \ inspection Number:8241dift�ZA }Unit: N/A \ Lead|nspeocor:BxnKYSTPmTTOm | Uther\nspeuors: m/A { Fee:$15O.OU ;7 ���w.�' ^���
mTmTmm CODE ocscm/pr/om
FAIL 505.1 xddress\dentificat\on New and existing buildings shall be provided with approved address identification.
The address identification shall be legible and placed in a position that is visible from
the street or road fronting the property.Address identification characters shall
contrast with their background.Address numbers shall be Arabic numbers or
alphabetical letters. Numbers shall not be spelled Out. Each character shall be not
less than 4 inches(102 mm)high with a minimum stroke width of 1/2(12.7
Where required by the fire code official,address identification shall be provided in
additional approved locations to facilitate emergency response.Where access is by
means of a private road and the building cannot be viewed from the public way,a
monument,pole or other sign nr means shall be used ro identify tile structure.
Address identification shall bemaintained.
Inspector: BARRYSTRATTON Comments:Still no address posted
FAIL 6051 Abatement of |denr�ede|pohca| hazards shall be abated. identUiedhazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: 8xRRvSTR/TT0N Comments: Electric work still not corrected
FAIL 907.2.11 Single-and Listed single-and multiple-station smoke alarms complying with UL217shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.0 and mpPx 72.
alarms
Inspector: 8ARRvSTRATTOm Comments:Smoke detectors need installed tomeet
code requirements.
FAIL R2 Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may
include boUers,heating equipment,e|evator, moving stairways,electrical wiring' and
flammable liquid containers.(|PM[108.1.2)
mspeuocBARRY STRATT N Comments: Hot water heater.
FAIL R5 [ute/iorStruoure is the exterior of the Structure maintained in good repair,structurally sound and
sanitary state7(|PM[304)
r primeo onmo7Q'm �,-T`Oi-24
. `
STATUS CODE ouSca/pnmm
inspector: BARRYSTRATTON Comments:Front steps still not repaired and handrail
is not attached making itunsafe.
FAIL R6I. Mechan\ca| Eqiupmenz Are mechanical appliances properly installed and rnaintained in good working
condition?(|PM[6Ol1)
Inspector:BARRvSTRATTON Cnmmenrs:vvarerhearer
sumfRxLmoTES
BARRvSTRATTON 07/27/2022@10:23 304.3 Prernises identification. Buildings shall have approved address numbers placed
in a position to be plainly legible and visible from the street or road fronting the
property.These numbers shall contrast with their background.Address numbers shall
be Arabic numerals or alphabet letters. Numbers shall be not less than 4 inches(102
mm)in height with a minimum stroke width ofO.5 inch(1I7 nnn).
BAnRvSTRATTUN 07/27/2022@10:23 304.10 Stairways,decks, porches and balconies. Every exterior stairway,deck, porch
and balcony,and all appurtenances attached thereto,shall be maintained structurally
sound, in good repair,with proper anchorage and capable of supporting the imposed
loads.
BARRYSTRATTON 07/27/2822@10:23 304.12 Handrails and guards. Every handrail and guard shall be firmly fastened and
capable of supporting normally imposed loads and shall be maintained in good
condition.
8ARRYSTRATTOm 07/27/2022@10:I3 109.4Vio|ation penalties.Any person who shall violate a provision of this code,orfail
to comply therewith,or with any of the requirements thereof,shall be prosecuted
within the limits provided by state or local laws. Each day that a violation continues
after due notice has been served shall be deemed a separate offense. Past attempts to
serve citation to listed address on Deed have went unserved because address in
undeliverable. Need updated semiceinformacion.
8ARRYSTRA7TON 07/27/2022@10:23 William(8iU)Gilliam is agent for listed address. _
nE/xmpEcr/Omo4rc
O8/30/2U22
|
�
'7on�22�10iZ4
Page zmo
•
CONTACT SIONATUIE
UNIVERSAL ACCESS MORT MIDWEST LL
Signed on:07/27/2022 @ 10:24
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:07/27/2022 @ 10:24
QUESTIONS ABOUT YOUR INSPECTION?
BARRY STRATTON
barry.stratton@waterloo-ia.org
(319)231-9147
= 07,27,2022, 10:24
Page 3 of 3