Loading...
HomeMy WebLinkAbout3863 PAIGE DR INVOICE DATE DUE DATE INVOICE# TOTAL DUE �1���' 1'I rot 10/17/2022 11/20/2022 �4MIS/� 2023-00020263 $100.00 °1erloo No Customer#: 23944 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable WATERLOO INVESTMENT GROUP LLC 715 Mulberry St 3 863 PAIGE DR WATERLOO, IA 50703 WATERLOO,IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 3863 PAIGE DR- 10-13-22 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price FAILURE TO OBTAIN PERMIT $100.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23944 10/17/2022 11/20/2022 2023-00020263 $100.00 Less Prepayment $0.00 Total Due—> $100.00 City of Waterloo WATERLOO FIRE RESCUEto!tz, INSPECTION REPORT 1 l ._)4° WATERLOO INVESTMENT GROUP LLC 8 PLEX,3863 PAIGE DR, WATERLOO IA S0702 DETAILS Inspection Date: 10/13/2022 { Inspection Type: Rental Inspection j Inspection Number:8976 ! Shift: N/A I Station: N/A Unit: N/A j Lead Inspector: BARRY STRATTON Other Inspectors: N/A ( Fee:$100.00 � ae0 STATUS CODE DESCRIPTION FAIL 1010.1.9-Door operations Except as specifically permitted by this section,egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON-Comments:Fire doors held in open position. FAIL 1031.7-Emergency escape Required emergency escape and rescue openings shall be maintained in accordance and rescue openings with the code in effect at the time of construction,and the following: Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars,grilles,grates or similar devices are allowed to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of a key,tool or force greater than that which is required for normal operation of the emergency escape and rescue opening. Inspector: BARRY STRATTON-Comments:Screens missing from windows in common hallways FAIL 506.1 -Where required Where access to or within a structure or an area is restricted because of secured openings or where immediate access is necessary for life-saving or fire-fighting purposes,the fire code official is authorized to require a key box to be installed in an approved location.The key box shall be of an approved type listed in accordance with UL 1037,and shall contain keys to gain necessary access as required by the fire code official. Inspector: BARRY STRATTON-Comments:Need knox boxes installed on building FAIL 703.2-Opening protectives Opening protectives shall be maintained in an operative condition in accordance with NFPA 80.Where allowed by the fire code official,the application of field-applied labels associated with the maintenance of opening protectives shall follow the requirements of the approved third-party certification organization accredited for listing the opening protective. Fire doors and smoke barrier doors shall not be blocked or obstructed,or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged. Fire door assemblies shall not be modified. Inspector: BARRY STRATTON-Comments:Fire doors held open. ntec Qn 10 2D22;c 4 0= Page 1 of 3 S a STATUS CODE DESCRIPTION FAIL 901.6-Inspection,testing and Fire detection,alarm,and extinguishing systems,mechanical smoke exhaust maintenance systems,and smoke and heat vents shall be maintained in an operative condition at all times,and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected,tested and maintained or removed. Inspector: BARRY STRATTON-Comments:Alarm need maintenance and testing FAIL 901.6.1 -Standards Fire protection systems shall be inspected,tested and maintained in accordance with the referenced standards listed in Table. Inspector: BARRY STRATTON-Comments:Alarm FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A,B, E, F, H, I, M, R-1, R-2,R-4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3.In areas where flammable or combustible liquids are stored, used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Inspector:BARRY STRATTON-Comments:Fire extinguishers need updated. FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11,1 through 907.2.11.6 and NFPA 72. alarms Inspector:BARRY STRATTON-Comments:Smoke detectors missing and some beeping FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector: BARRY STRATTON-Comments:Smoke detectors missing in common hallways FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition?(IPMC 603.1) Inspector: BARRY STRATTON-Comments:Fan cover missing in Laundry area GENERAL NOTES Printed vn 10 132022 a 14:05 Page 2 of 3 BARRY STRATTON-10/13/2022 @ 14:03 9-7-4 9-7-5 Rental registration is needed for listed address. Former owner did registered last year not have REINSPECTION DATE 11/14/2022 CONTACT SIGNATURE Matt Matthias /��� Signed on: 10/13/2022 @ 14:04 E' "f I IL-. INSPECTOR SIGNATURE BARRY STRATTON Signed on: 10/13/2022 @ 14:04 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Prrr:ed on i 0e'3,2022 3 14:05 Page 3 of 3