INSPECTION REPORT
MARILU SANCHEZ SINGLE FAMILY RENTAL,420 LANE ST, WATERLOO IA 50703 63 a" R
DETAILS
Inspection Date:09/14/2022 I Inspection Type: Rental Inspection I Inspection Number:8516 + Shift: N/A ; Station: N/A
Unit: N/A I Lead Inspector: BARRY STRATTON E Other Inspectors: N/A ( Fee:$100.00
e/e f 4/f t#Z1-11
STATUS CODE DESCRIPTION /5(4 - g j+p r(ef
FAIL 1010.1.9-Door operations Except as specifically permitted by this section,egress doors shall be readily
openable from the egress side without the use of a key or special knowledge or
effort.
Inspector: BARRY STRATTON-Comments:
FAIL 1031.7-Emergency escape Required emergency escape and rescue openings shall be maintained in accordance
and rescue openings with the code in effect at the time of construction,and the following: Required
emergency escape and rescue openings shall be operational from the inside of the
room without the use of keys or tools. Bars,grilles,grates or similar devices are
allowed to be placed over emergency escape and rescue openings provided the
minimum net clear opening size complies with the code that was in effect at the time
of construction and such devices shall be releasable or removable from the inside
without the use of a key,tool or force greater than that which is required for normal
operation of the emergency escape and rescue opening.
Inspector: BARRY STRATTON-Comments:Windows not functional
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring, devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRY STRATTON-Comments:Open electrical boxes in living room and by
back basement stairs. Exposed electrical wires in unit. Need globes on all light.
Remove all extension cords. Burnt electrical outlets need replaced by licensed
electrician. Need approved covers on all outlets and switches. Lighting requirements
for the upstairs not being met.
FAIL 703.2-Opening protectives Opening protectives shall be maintained in an operative condition in accordance with
NFPA 80.Where allowed by the fire code official,the application of field-applied labels
associated with the maintenance of opening protectives shall follow the
requirements of the approved third-party certification organization accredited for
listing the opening protective. Fire doors and smoke barrier doors shall not be
blocked or obstructed,or otherwise made inoperable. Fusible links shall be replaced
promptly whenever fused or damaged. Fire door assemblies shall not be modified.
Inspector: BARRY STRATTON-Comments:
P-nteo on D9,, '0. 5
Page 1 of 7
STATUS CODE DESCRIPTION
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1.In new
and existing Group A,B,E, F, H, I,M,R-1,R-2, R-4 and S occupancies. Exception:In
Group R-2 occupancies,portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm)
of commercial cooking equipment.3. In areas where flammable or combustible
liquids are stored,used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies,in accordance with Section 3315.1.5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas,
including but not limited to laboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector: BARRY STRATTON-Comments:
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector:BARRY STRATTON-Comments:Need smoke detectors installed to meet
rental requirements.
FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector:BARRY STRATTON-Comments:CO detectors need installed in vicinity of
the bedrooms on main level and upstairs.
FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may
include boilers,heating equipment,elevator,moving stairways,electrical wiring,and
flammable liquid containers.(IPMC 108.1.2)
Inspector:BARRY STRATTON-Comments:Furnace and water heater
FAIL R3-Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPMC
Occupancy 108.1.3)
Inspector:BARRY STRATTON-Comments:Condition of unit does not meet code
requirements. Potential lead base paint in house.
Pruned on 09/14/2022,t 14:46
Page 2 of 7
STATUS CODE DESCRIPTION
FAIL R4- Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This
includes grading and drainage,sidewalks and driveways,weeds,and pest
infestations.(IPMC 302)
Inspector:BARRY STRATTON-Comments:Roof and sofit area have large holes that
need corrected. Need landing replaced at front of residence. Need rear entrance
landing and stairs replaced.Need handrails on exterior stairs. Broken window and
windows that do not open. Exterior doors need replaced.Gutters missing need
replaced.Need screen on all windows.
FAIL R5- Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and
sanitary state?(IPMC 304)
Inspector:BARRY STRATTON-Comments:Doors,windows,stairs,landings,paint,
holes in walls,foundation cracks.
FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector:BARRY STRATTON-Comments:Doors,windows,holes in walls,peeling
paint,collapse ceilings by back door,flooring in unit needs replaced in several areas,
carpet not tacked down, bath cabinet needs replaced, porch and landing at door
unsafe, hardware on doors missing,open ducts in basement not attached to
registers, handrail of basement missing,balusters missing to upstairs,guard railing
to upstairs unstable/unsafe, base boards and trim missing/damaged, back doors
need replaced.Bathroom on 2nd floor is not functional.Flooring throughout needs
replaced.
FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
inspector: BARRY STRATTON-Comments:Mold,fire safety requirements not being
met
FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room
temperature of 68F?(IPMC 602.2)
Inspector:BARRY STRATTON-Comments: No permits or inspections on furnace
installed.
FAIL R6.C.- Mechanical Egiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector:BARRY STRATTON-Comments:No permits or inspection for new water
heater installed.Missing discharge tube on water heater.
Ponied on 09/14/2022 g 10.46
Page 3of7
STATUS CODE DESCRIPTION
FAIL R6.D.-Receptacles Every habitable space in a dwelling shall contain not less than two separate and
remote receptacle outlets. Every laundry area shall contain not less than one
grounding-type receptacle or a receptacle with a GFCI. Every bathroom shall contain
not less than one receptacle.Any new bathroom receptacle shall have GFCI
protection.All receptacles shall have the appropriate faceplate cover.(IPMC 605.2)
Inspector: BARRY STRATTON-Comments:Outlets not working throughout house.
GENERAL NOTES
BARRY STRATTON-09/14/2022 @ 10:40 9-7-4 9-7-5: Rental unit is not registered with the City of Waterloo.This is an
unregistered rental unit. Unlawful to rent unit without registration. Still not registered.
BARRY STRATTON-09/14/2022 @ 10:41 304.5 Foundation walls. Foundation walls shall be maintained plumb and free from
open cracks and breaks and shall be kept in such condition so as to prevent the entry
of rodents and other pests.
BARRY STRATTON-09/14/2022 @ 10:41 304.7 Roofs and drainage.The roof and flashing shall be sound,tight and not have
defects that admit rain. Roof drainage shall be adequate to prevent dampness or
deterioration in the walls or interior portion of the structure. Roof drains,gutters and
downspouts shall be maintained in good repair and free from obstructions. Roof water
shall not be discharged in a manner that creates a public nuisance.
BARRY STRATTON-09/14/2022 @ 10:41 304.10 Stairways, decks, porches and balconies. Every exterior stairway,deck, porch
and balcony,and all appurtenances attached thereto,shall be maintained structurally
sound, in good repair,with proper anchorage and capable of supporting the imposed
loads
BARRY STRATTON-09/14/2022 @ 10:41 304.12 Handrails and guards. Every handrail and guard shall be firmly fastened and
capable of supporting normally imposed loads and shall be maintained in good
condition.
BARRY STRATTON-09/14/2022 @ 10:41 304.13 Window,skylight and door frames. Every window,skylight, door and frame shall
be kept in sound condition,good repair and weather tight.
BARRY STRATTON-09/14/2022 @ 10:42 304.13.2 Openable windows. Every window,other than a fixed window,shall be easily
openable and capable of being held in position by window hardware.
Prinntec or,O9+' Za22 1,45
Page 4 of 7
GENERAL NOTES
BARRY STRATTON-09/14/2022 @ 10:42 304.14 Insect screens.every door,window and other outside opening required for
ventilation of habitable rooms, food preparation areas,food service areas or any areas
where products to be included or utilized in food for human consumption are
processed, manufactured, packaged or stored shall be supplied with approved tightly
fitting screens of minimum 16 mesh per inch(16 mesh per 25 mm),and every screen
door used for insect control shall have a self-closing device in good working condition.
BARRY STRATTON-09/14/2022 @ 10:42 304.15 Doors. Exterior doors,door assemblies,operator systems if provided,and
hardware shall be maintained in good condition. Locks at all entrances to dwelling
units and sleeping units shall tightly secure the door. Locks on means of egress doors
shall be in accordance with Section 702.3.
BARRY STRATTON-09/14/2022 @ 10:42 305.1 General.The interior of a structure and equipment therein shall be maintained in
good repair, structurally sound and in a sanitary condition. Occupants shall keep that
part of the structure that they occupy or control in a clean and sanitary condition.
Every owner of a structure containing a rooming house, housekeeping units,a hotel,a
dormitory,two or more dwelling units or two or more nonresidential occupancies,
shall maintain, in a clean and sanitary condition,the shared or public areas of the
structure and exterior property.
BARRY STRATTON-09/14/2022 @ 10:42 305.3 Interior surfaces. Interior surfaces,including windows and doors,shall be
maintained in good,clean and sanitary condition. Peeling,chipping,flaking or abraded
paint shall be repaired,removed or covered. Cracked or loose plaster,decayed wood
and other defective surface conditions shall be corrected.
BARRY STRATTON-09/14/2022 @ 10:43 305.4 Stairs and walking surfaces. Every stair, ramp,landing, balcony, porch, deck or
other walking surface shall be maintained in sound condition and good repair.
BARRY STRATTON-09/14/2022 @ 10:43 305.6 Interior doors. Every interior door shall fit reasonably well within its frame and
shall be capable of being opened and closed by being properly and securely attached
to jambs, headers or tracks as intended by the manufacturer of the attachment
hardware.
BARRY STRATTON-09/14/2022 @ 10:43 309.1 Infestation.Structures shall be kept free from insect and rodent infestation.
Structures in which insects or rodents are found shall be promptly exterminated by
approved processes that will not be injurious to human health.After pest elimination,
proper precautions shall be taken to prevent reinfestation.
P<.nted an 99,14;2C,22 4:
Page 5 of 7
GENERAL NOTES
BARRY STRATTON-09/14/2022 @ 10:43 403.2 Bathrooms and toilet rooms. Every bathroom and toilet room shall comply with
the ventilation requirements for habitable spaces as required by Section 403.1,except
that a window shall not be required in such spaces equipped with a mechanical
ventilation system.Air exhausted by a mechanical ventilation system from a bathroom
or toilet room shall discharge to the outdoors and shall not be recirculated. Need bath
fan replaced and installed to code. Current bath fan is not rated for a wet location
(shower).
BARRY STRATTON-09/14/2022 @ 10:43 504.1 General, Plumbing fixtures shall be properly installed and maintained in working order,and shall be kept free from obstructions, leaks and defects and be capable of
performing the function for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe,sanitary and functional condition
BARRY STRATTON-09/14/2022 @ 10:44 505.4 Water heating facilities.Water heating facilities shall be properly installed,
maintained and capable of providing an adequate amount of water to be drawn at
every required sink, lavatory,bathtub, shower and laundry facility at a temperature not
less than 110°F(43°C).A gas-burning water heater shall not be located in any
bathroom,toilet room, bedroom or other occupied room normally kept closed, unless
adequate combustion air is provided.An approved combination temperature and
pressure-relief valve and relief valve discharge pipe shall be properly installed and
maintained on water heaters.
BARRY STRATTON-09/14/2022 @ 10:44 603.1 Mechanical equipment and appliances. Mechanical equipment,appliances,
fireplaces, solid fuel-burning appliances, cooking appliances and water heating
appliances shall be properly installed and maintained in a safe working condition,and
shall be capable of performing the intended function
BARRY STRATTON-09/14/2022 @ 10:44 604.3 Electrical system hazards.Where it is found that the electrical system in a
structure constitutes a hazard to the occupants or the structure by reason of
inadequate service, improper fusing, insufficient receptacle and lighting outlets,
improper wiring or installation,deterioration or damage,or for similar reasons,the
code official shall require the defects to be corrected to eliminate the hazard.
BARRY STRATTON-09/14/2022 @ 10:44 605.1 Installation. Electrical equipment,wiring and appliances shall be properly
installed and maintained in a safe and approved manner.
BARRY STRATTON-09/14/2022 @ 10:44 605.2 Receptacles. Every habitable space in a dwelling shall contain not less than two
separate and remote receptacle outlets. Every laundry area shall contain not less than
one grounding-type receptacle or a receptacle with a ground fault circuit interrupter.
Every bathroom shall contain not less than one receptacle.Any new bathroom
receptacle outlet shall have ground fault circuit interrupter protection.All receptacle
outlets shall have the appropriate faceplate cover for the location.
Pr;rIed on OS .4/2 10:45
Page 6of7
GENERAL NOTES
BARRY STRATTON-09/14/2022 @ 10:44 605.3 Luminaires. Every public hall,interior stairway,toilet room, kitchen
laundry room,boiler room and furnace room shall contain not less than lo
one
lelectric
luminaire. Pool and spa luminaires over 15 V shall have ground fault circuit interrupter
protection. Globes needed on lights.
BARRY STRATTON-09/14/2022 @ 10:45 607.1 General. Duct systems shall be maintained free of obstructions and
capable of performing the required function. shall he
BARRY STRATTON-09/14/2022 @ 10:45 701.2 Responsibility. The owner of the premises shall provide and ma
intain such fire
safety facilities and equipment in compliance with these requirements.A person shall
not occupy as owner-occupant or permit another person to occupy any premises that
do not comply with the requirements of this chapter.
BARRY STRATTON-09/14/2022 @ 10:45 702.1 General.A safe,continuous and unobstructed path of travel
from anyshall be provided
point in a building or structure to the public way. Means of egress shall
comply with the International Fire Code
REINSPECT/UN DATE
10/11/2022
CONTACT SIGNATURE
Marilu Sanchez /4f\v 1k_
Signed on:09/14/2022 @ 10:45 1
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:09/14/2022 @ 10:45
QUESTIONS ABOUT YOUR INSPECTION?
BARRY STRATTON
barry.stratton@waterloo-ia.org
(319)231-9147
Page 7 of 7