RENTAL INSPECTION- 1226 LANGLEY RD - 8-24-22 FOR BILLING INQUIRY: (319)291-4323
LDescription i Total Price J
REINSPECTION FEE 3RD $250.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
23941 10/17/2022 11/20/2022 2023-00020276 $250.00
Less Prepayment $0.00
Total Due $250.00
City of Waterloo
B.
1 L -\ LLILLt€yi
WATERLOO FIRE RESCUE � as u�a Sci'J
��
INSPECTION REPORT
LiOL136 SOO � .
1226 LANGLEY LLC 8-PLEX, 1226 LANGLEY RD,WATERLOO IA 50702
DETAILS
Inspection Date:08/24/2022 I Inspection Type: Rental Inspection Inspection Number: 8424 j Shift: N/A ( Station: N/A
Unit: N/A Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$250.00
� O// ' - 45
3 �
STATUS CODE DESCRIPTION
FAIL 1008.1 -Means of egress Illumination shall be provided in the means of egress in accordance with Section
illumination 1008.2. Under emergency power, means of egress illumination shall comply with
Section 1008.3.
Inspector: BARRY STRATTON-Comments:Egress light on rear entrance door still not
repaired
FAIL 1010.1.9- Door operations Except as specifically permitted by this section,egress doors shall be readily
openable from the egress side without the use of a key or special knowledge or
effort.
Inspector: BARRY STRATTON-Comments:Unit#2 door.Front entrance to 1226 the
hinges are damaged.
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRY STRATTON-Comments:Exposed wires by front door. Need globes
on all lights. Remove extension cords from ceiling. light in hallway falling off wall.
Loving room light hanging from ceiling grid.
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new
and existing Group A, B, E, F, H, I, M, R-1,R-2, R-4 and S occupancies. Exception: In
Group R-2 occupancies,portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm)
of commercial cooking equipment.3. In areas where flammable or combustible
liquids are stored, used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies,in accordance with Section 3315.1.5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas,
including but not limited to laboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector:BARRY STRATTON-Comments:
Printed on 08/24,2022 05_23
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector:BARRY STRATTON-Comments:Smoke detectors needed in each bedroom
and outside of bedrooms.
FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector:BARRY STRATTON-Comments:Need CO detector.
FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may
include boilers,heating equipment,elevator,moving stairways,electrical wiring,and
flammable liquid containers.(IPMC 108.1.2)
Inspector:BARRY STRATTON-Comments:Electric
FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector:BARRY STRATTON-Comments:Water damage to kitchen cabinets. Drawers
and doors damage and do not close and latch. Door hardware missing on pantry.
Bathroom ceiling missing from water damage.Mold adn mushrooms growing in
ceiling cavity. Door trim on front door missing. Missing exhaust fan on bath fan.Stove
needs replace because door is damaged.
FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector:BARRY STRATTON-Comments:Electrical, bathroom mold,water damage,
fire extinguishers discharged,missing smoke detectors and CO detectors.
FAIL R6.C.- Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector:BARRY STRATTON-Comments:Bath exhaust fan missing cover,&Stove
needs replaced.
GENERAL NOTES
BARRY STRATTON-08/24/2022 @ 06:21 Ceiling tiles missing in common areas and laundry rooms. Fire extinguishers need
maintenance and holes in walls need repaired.
Printed an 03/24/2022 t 06:23
Page 2 of 3
GENERAL NOTES
BARRY STRATTON-08/24/2022 @ 06:21 403.6 Mold Present In A Rental Unit.a.When mold is found to be visibly present in
small amounts, it can be cleaned in a safe and sanitary manner.b.When mold is found
in a rental unit and is determined to be a health risk,the building official may order
that a clean air report be obtained from a mold specialist approved by the building
official.
BARRY STRATTON-08/24/2022 @ 06:22 Need licensed professionals to do electrical work and mold mitigation.
BARRY STRATTON-08/24/2022 @ 06:22 9-7-7:3rd failed re-inspection fee of$250.00
RWINSPECTION DATE
09/28/2022
CONTACT SIGNATURE
Samir Duratovic
Signed on:08/24/2022 @ 06:22 /\\/\\�
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:08/24/2022 @ 06:23
QUESTIONS ABOUT YOUR INSPECTION?
BARRY STRATTON
barry.stratton@waterloo-ia.org
(319)231-9147
Printed or,08.+24/2022 g 06:23