Loading...
HomeMy WebLinkAbout1226 LANGLEY RD (2) INVOICE DATE DUE DATE INVOICE# TOTAL DUE /ir'�� ■ �; 10/17/2022 11/20/2022 2023-00020277 $150.00 41' Ty 4'erloV) Customer#: 23941 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 1226 LANGLEY LLC 715 Mulberry St 1462 SOUTH HILL WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION- 1226 LANGLEY RD -7-25-22 FOR BILLING INQUIRY: (319)291-4323 LDescription Total Price j REINSPECTION FEE 2ND $150.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23941 10/17/2022 _ 11/20/2022 2023-00020277 $150.00 Less Prepayment $0.00 Total Due-* $150.00 City of Waterloo LLC WATERLOO FIRE RESCUES il; INSPECTION REPORT �'✓ / (oDCr � � r 1226 LANGLEY LW 8-FLEX, 1226 LANGLEY RD, WATERLOO IA SO702 v"' A� ° S 3- a f I DETAILS Inspection Date:07/25/2022 Inspection Type: Rental Inspection ; Inspection Number: 7888 Sh'ft: N/A j Station: N/A I Unit: N/A ; Lead Inspector: BARRY STRATTON I Other Inspectors: N/A ; Fee:$150.00 ez Mot / ,O .104,, STATUS CODE DESCRIPTION FAIL 1008.1 -Means of egress Illumination shall be provided in the means of egress in accordance with Section illumination 1008.2. Under emergency power, means of egress illumination shall comply with Section 1008.3. Inspector: BARRY STRATTON-Comments:Egress light on rear entrance door still not repaired FAIL 1010.1.9- Door operations Except as specifically permitted by this section,egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON-Comments:Unit#2 door. Front entrance to 1226 the hinges are damaged. FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:BARRY STRATTON-Comments: Exposed wires by front door. Need globes on all lights. Remove extension cords from ceiling. light in hallway falling off wall. Loving room light hanging from ceiling grid. FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3. In areas where flammable or combustible liquids are stored, used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies, in accordance with Section 3315.1.5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories,computer rooms and generator rooms, where required by the fire code official. Inspector: BARRY STRATTON-Comments: Page 1 of 3 STATUS CODE DESCRIPTION FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector: BARRY STRATTON-Comments:Smoke detectors needed in each bedroom and outside of bedrooms. FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector: BARRY STRATTON-Comments:Need CO detector. FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may include boilers,heating equipment,elevator,moving stairways,electrical wiring,and flammable liquid containers.(IPMC 108.1.2) Inspector: BARRY STRATTON-Comments:Electric FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound.and in a sanitary condition?(IPMC 305) Inspector: BARRY STRATTON-Comments:Water damage to kitchen cabinets.Drawers and doors damage and do not close and latch. Door hardware missing on pantry. Bathroom ceiling missing from water damage. Mold adn mushrooms growing in ceiling cavity. Door trim on front door missing. Missing exhaust fan on bath fan.Stove needs replace because door is damaged. FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions Inspector:BARRY STRATTON-Comments: Electrical, bathroom mold,water damage, fire extinguishers discharged, missing smoke detectors and CO detectors. FAIL R6.C.- Mechanical Egiupment Are mechanical appliances properly installed and maintained in good working condition?(IPMC 603.1) Inspector: BARRY STRATTON-Comments:Bath exhaust fan missing cover,&Stove needs replaced. GENERAL NOTES BARRY STRATTON-07/25/2022 @ 11:21 Ceiling tiles missing in common areas and laundry rooms. Fire extinguishers need maintenance and holes in walls need repaired. P-inted on 07/25/202 .c._23 Page 2 of 3 6mNERAL NOTES uAnRYSTKA7TON 07/25Q022 @11:21 403.6 Mold Present In A Rental Unit.a.When mold is found to be visibly present in small amounts, it can be cleaned in a safe and sanitary manner. b.When mold is found in a rental unit and is determined to be a health risk the building official may order that a clean air report be obtained from a mold specialist approved by the building official. 8ARRYSTRAlTON 07/25/2022@11:21 Need licensed professionals todo electrical work and mold mitigation. uxnRY STRAlTON 07/25/2022 @ 11:22 0'7'7:2nd re-inspection fee of$150.U0 REImSPECIrION DATE o8/22/20J2 CONTACT SIGNATURE SamirDuratovic Signed on:O7/ZS/2022@11:ZZ xmSPECTmgmx6mmwxURE 8ARRvSTRATT0N Signed on:07/2S/202Z@ 11:22 QUESTIONS ABOUT YOUR INSPECTION? BARRvSTRATTON barry.straunn@wate/'|ou'ia.org (319)231'0147 Page noro