RENTAL INSPECTION- 218 SOUTH ST- 9-12-22
FOR BILLING INQUIRY: (319)291-4323
LDescription
Total Price j
REINSPECTION FEE 1ST
$50.00
CUSTOMER# BILLING DATE I DUE DATE INVOICE#
23940 10/17/2022 11/20/2022 cxaRGEs
2023-00020278 $50.00
Less Prepayment $0.00
Total Due $50.00
City of Waterloo
J�pYEA1,�
WATERLOO FIRE RESCUE cprofaALva)
4: 0
.r
INSPECTION REPORT ��
218 SOUTH ST, WATERLOO IA 50701 381 C� � �� rLiv) � RE �
DETAILS C—A-
Inspection Date:09/12/2022 1 Inspection Type: Rental Inspection I Inspection Number:7196E Shift: N/A Station: N/A I
Unit: N/A I Lead Inspector:BARRY STRATTON Other Inspectors: N/A j Fee:$50.00
STATUS CODE DESCRIPTION
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector:BARRY STRATTON-Comments:Bath Fan
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new
and existing Group A, B, E,F, H,I, M, R-1, R-2, R-4 and S occupancies. Exception: In
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm)
of commercial cooking equipment.3. In areas where flammable or combustible
liquids are stored, used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas,
including but not limited to laboratories, computer rooms and generator rooms,
where required by the fire code official.
Inspector:BARRY STRATTON-Comments:
FAIL R5- Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and
sanitary state?(IPMC 304)
Inspector:BARRY STRATTON-Comments:Door and windows weatherization
FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector: BARRY STRATTON-Comments:bathroom floor, Kitchen floor,living room
floor carpet all need replaced.Walls in bathroom have water damage and holes need
fixed.All outlets need covers. Holes in living room floor.All floors shall be maintained
in good condition.Several trip hazards with carpet. Living room ceiling is falling.
FAIL R6.C.- Mechanical Egiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Prirtect ar,09;1 212022 14_43
Page 1 of 3
STATUS CODE DESCRIPTION
Inspector: BARRY STRATTON-Comments:Bath fan need replaced.
FAIL R6.D. - Receptacles Every habitable space in a dwelling shall contain not less than two separate and
remote receptacle outlets. Every laundry area shall contain not less than one
grounding-type receptacle or a receptacle with a GFCI. Every bathroom shall contain
not less than one receptacle.Any new bathroom receptacle shall have GFCI
protection.All receptacles shall have the appropriate faceplate cover.(IPMC 605.2)
Inspector: BARRY STRATTON-Comments:Need approved convers on all outlets
GENERAL NOTES
BARRY STRATTON-09/12/2022 @ 14:41 304.13 Window,skylight and door frames. Every window, skylight,door and frame shall
be kept in sound condition,good repair and weather tight.
BARRY STRATTON-09/12/2022 @ 14:41 305.3 Interior surfaces. Interior surfaces,including windows and doors,shall be
maintained in good,clean and sanitary condition. Peeling,chipping,flaking or abraded
paint shall be repaired, removed or covered.Cracked or loose plaster,decayed wood
and other defective surface conditions shall be corrected.
BARRY STRATTON-09/12/2022 @ 14:41 305.4 Stairs and walking surfaces. Every stair,ramp, landing,balcony,porch,deck or
other walking surface shall be maintained in sound condition and good repair.
BARRY STRATTON-09/12/2022 @ 14:42 403.2 Bathrooms and toilet rooms. Every bathroom and toilet room shall comply with
the ventilation requirements for habitable spaces as required by Section 403.1,except
that a window shall not be required in such spaces equipped with a mechanical
ventilation system.Air exhausted by a mechanical ventilation system from a bathroom
or toilet room shall discharge to the outdoors and shall not be recirculated.
BARRY STRATTON-09/12/2022 @ 14:42 504.1 General. Plumbing fixtures shall be properly installed and maintained in working
order,and shall be kept free from obstructions,leaks and defects and be capable of
performing the function for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe,sanitary and functional condition
BARRY STRATTON-09/12/2022 @ 14:42 503.4 Floor surface. In other than dwelling units, every toilet room floor shall be
maintained to be a smooth, hard, nonabsorbent surface to permit such floor to be
easily kept in a clean and sanitary condition.Shower pan need replaced.
BARRY STRATTON-09/12/2022 @ 14:42 702.1 General.A safe,continuous and unobstructed path of travel shall be provided
from any point in a building or structure to the public way. Means of egress shall
comply with the International Fire Code. Egress path has obstructions in apartment.
Filmed on^ -_
Page 2 of 3
REINSPECTION DATE
10/11/2022
CONTACT SIGNATURE
Martin Realtors
Signed on:09/12/2022 @ 14:42 - 11\1\PA,\
INSPECTOR SIGNATURE
BARRY STRATTON �----
Signed on:09/12/2022 @ 14:42