RENTAL INSPECTION- 1202 W 2ND ST- 8-8-22 FOR BILLING INQUIRY: (319)291-4323
LDescription l Total Price
REINSPECTION FEE 2ND $150.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
23001 10/17/2022 11/20/2022 2023-00020280 $150.00
Less Prepayment $0.00
Total Due-* $150.00
City of Waterloo
WATERLOO FIRE RESCUEo
INSPECTION REPORT a •., ,
QUALITY CONCRETE MULTI-RESIDENTIAL RENTALS, 1202 W 2ND ST,WATERLOO IA S0701
DETAILS
Inspection Date:08/08/2022 I Inspection Type: Rental Inspection I Inspection Number: 8303 i Shif: N/A Station: N/A I
Unit: N/A ( Lead Inspector: BARRY STRATTON f Other Inspectors: N/A j Fee:$150.00 A(4 �s
STATUS CODE DESCRIPTION
FAIL 1018.1 -General Aisles and aisle accessways serving as a portion of the exit access in the means of
egress system shall comply with the requirements of this section.Aisles or aisle
accessways shall be provided from all occupied portions of the exit access that
contain seats,tables,furnishings,displays and similar fixtures or equipment.The
minimum width or required capacity of aisles shall be unobstructed. Exception:
Encroachments complying with Section 1005.7.
Inspector: BARRY STRATTON-Comments:
FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector: BARRY STRATTON-Comments:Doors and jambs
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRY STRATTON-Comments:Missing globes,electric panel blocked,and
appliances in basement blocking egress path.
n(ed Or v'
Page 1 of 4
STATUS CODE DESCRIPTION
FAIL 703.1 - Maintenance The required fire-resistance rating of fire-resistance-rated construction, including,
but not limited to,walls,firestops, shaft enclosures, partitions, smoke barriers,
floors,fire-resistive coatings and sprayed fire-resistant materials applied to
structural members and fire-resistant joint systems,shall be maintained.Such
elements shall be visually inspected by the owner annually and properly repaired,
restored or replaced where damaged,altered, breached or penetrated. Records of
inspections and repairs shall he maintained.Where concealed,such elements shall
not be required to be visually inspected by the owner unless the concealed space is
accessible by the removal or movement of a panel,access door,ceiling tile or similar
movable entry to the space.Openings made therein for the passage of pipes,
electrical conduit,wires,ducts,air transfer openings and holes made for any reason
shall be protected with approved methods capable of resisting the passage of smoke
and fire. Openings through fire-resistance-rated assemblies shall be protected by
self-or automatic-closing doors of approved construction meeting the fire protection
requirements for the assembly.
Inspector: BARRY STRATTON-Comments:Ceiling in living room,water damage in
living room,walls damaged from water,floor and walls have holes.
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new
and existing Group A, B, E, F, H, I, M,R-1, R-2, R-4 and S occupancies. Exception: In
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mill)
of commercial cooking equipment.3. In areas where flammable or combustible
liquids are stored, used or dispensed.4. On each floor of structures under
construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas,
including but not limited to laboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector: BARRY STRATTON-Comments:
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector: BARRY STRATTON-Comments:
FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector: BARRY STRATTON-Comments:
FAIL R1 - Unsafe Structures Is the structure found to be dangerous to the life, health, property or safety of either
the public or occupants of the structure?(IPMC 108.1.1)
Page 2 of 4
STATUS CODE DESCRIPTION
inspector: BARRY STRATTON-Comments:Apartment is not habitable
FAIL R3-Unfit for Human is the structure found to be fit for human occupancy according to the code?(IPMC
Occupancy 108,1.3)
Inspector: BARRY STRATTON-Comments:
FAIL R5-Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and
sanitary state?(IPMC 304)
Inspector: BARRY STRATTON-Comments: Deck stairs and landing. Handrails to
apartment.
FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector: BARRY STRATTON-Comments:Entry door needs replaced.jamb and door
are broken. Broken windows need replaced. Egress path is blocked in kitchen
because refrigerator is blocking path.Ceiling in living room has collapsed.Ceiling tiles
are damaged by water leak. bath sink is not secured to wall in bathroom.Sewer leak
in basement needs repaired by licensed professional.Screen door does not have any
door hardware. Back door to 1202 did not function because tenant advised it is
broken.Security hardware to keep door secured in jamb is broken and jamb not
capable to keep door secured and weather tight.
FAIL R6.A. -Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector: BARRY STRATTON- Comments:Mold and water damage
FAIL R6.C.- Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition?(I PMC 603.1)
Inspector: BARRY STRATTON-Comments:Furnace can not maintain 68 degrees with
all the broken windows in building. Maintenance to furnace needed and new windows
need installed in building.This issue was noted back in October 2021.
REINSPECTION DATE
09/12/2022
Printed on 03:_2022= 33
Page 3 of 4
•
CONTACT SIGNATURE
Quality Concrete Construction
Signed on:08/08/2022 @ 13:32
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:08/08/2022 @ 13:32