Loading...
HomeMy WebLinkAbout1202 W 2ND ST INVOICE DATE DUE DATE INVOICE# TOTAL DUE ATariti, Ne.t 10/17/2022 11/20/2022 2023-00020280 $150.00 ��entoo �o Customer#: 23001 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable QUALITY CONCRETE CONTRUCTION(RENTAL) 715 Mulberry St 1930 HAWTHORNE AVE#1 WATERLOO, IA 50703 WATERLOO,IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION- 1202 W 2ND ST- 8-8-22 FOR BILLING INQUIRY: (319)291-4323 LDescription l Total Price REINSPECTION FEE 2ND $150.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23001 10/17/2022 11/20/2022 2023-00020280 $150.00 Less Prepayment $0.00 Total Due-* $150.00 City of Waterloo WATERLOO FIRE RESCUEo INSPECTION REPORT a •., , QUALITY CONCRETE MULTI-RESIDENTIAL RENTALS, 1202 W 2ND ST,WATERLOO IA S0701 DETAILS Inspection Date:08/08/2022 I Inspection Type: Rental Inspection I Inspection Number: 8303 i Shif: N/A Station: N/A I Unit: N/A ( Lead Inspector: BARRY STRATTON f Other Inspectors: N/A j Fee:$150.00 A(4 �s STATUS CODE DESCRIPTION FAIL 1018.1 -General Aisles and aisle accessways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section.Aisles or aisle accessways shall be provided from all occupied portions of the exit access that contain seats,tables,furnishings,displays and similar fixtures or equipment.The minimum width or required capacity of aisles shall be unobstructed. Exception: Encroachments complying with Section 1005.7. Inspector: BARRY STRATTON-Comments: FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector: BARRY STRATTON-Comments:Doors and jambs FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON-Comments:Missing globes,electric panel blocked,and appliances in basement blocking egress path. n(ed Or v' Page 1 of 4 STATUS CODE DESCRIPTION FAIL 703.1 - Maintenance The required fire-resistance rating of fire-resistance-rated construction, including, but not limited to,walls,firestops, shaft enclosures, partitions, smoke barriers, floors,fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems,shall be maintained.Such elements shall be visually inspected by the owner annually and properly repaired, restored or replaced where damaged,altered, breached or penetrated. Records of inspections and repairs shall he maintained.Where concealed,such elements shall not be required to be visually inspected by the owner unless the concealed space is accessible by the removal or movement of a panel,access door,ceiling tile or similar movable entry to the space.Openings made therein for the passage of pipes, electrical conduit,wires,ducts,air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance-rated assemblies shall be protected by self-or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Inspector: BARRY STRATTON-Comments:Ceiling in living room,water damage in living room,walls damaged from water,floor and walls have holes. FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A, B, E, F, H, I, M,R-1, R-2, R-4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mill) of commercial cooking equipment.3. In areas where flammable or combustible liquids are stored, used or dispensed.4. On each floor of structures under construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories,computer rooms and generator rooms, where required by the fire code official. Inspector: BARRY STRATTON-Comments: FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector: BARRY STRATTON-Comments: FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector: BARRY STRATTON-Comments: FAIL R1 - Unsafe Structures Is the structure found to be dangerous to the life, health, property or safety of either the public or occupants of the structure?(IPMC 108.1.1) Page 2 of 4 STATUS CODE DESCRIPTION inspector: BARRY STRATTON-Comments:Apartment is not habitable FAIL R3-Unfit for Human is the structure found to be fit for human occupancy according to the code?(IPMC Occupancy 108,1.3) Inspector: BARRY STRATTON-Comments: FAIL R5-Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and sanitary state?(IPMC 304) Inspector: BARRY STRATTON-Comments: Deck stairs and landing. Handrails to apartment. FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector: BARRY STRATTON-Comments:Entry door needs replaced.jamb and door are broken. Broken windows need replaced. Egress path is blocked in kitchen because refrigerator is blocking path.Ceiling in living room has collapsed.Ceiling tiles are damaged by water leak. bath sink is not secured to wall in bathroom.Sewer leak in basement needs repaired by licensed professional.Screen door does not have any door hardware. Back door to 1202 did not function because tenant advised it is broken.Security hardware to keep door secured in jamb is broken and jamb not capable to keep door secured and weather tight. FAIL R6.A. -Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions Inspector: BARRY STRATTON- Comments:Mold and water damage FAIL R6.C.- Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition?(I PMC 603.1) Inspector: BARRY STRATTON-Comments:Furnace can not maintain 68 degrees with all the broken windows in building. Maintenance to furnace needed and new windows need installed in building.This issue was noted back in October 2021. REINSPECTION DATE 09/12/2022 Printed on 03:_2022= 33 Page 3 of 4 • CONTACT SIGNATURE Quality Concrete Construction Signed on:08/08/2022 @ 13:32 INSPECTOR SIGNATURE BARRY STRATTON Signed on:08/08/2022 @ 13:32 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Prated on 08108,2022 tc 13:33 Page 4 of 4