RENTAL INSPECTION- 2223FALLS AVE- 10-24-22 FOR BILLING INQUIRY: (319)291-4323
Description I Total Price
REINSPECTION FEE 2ND $150.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
23947 02/13/2023 03/20/2023 2023-00020347 $150.00
Less Prepayment $0.00
Total Due —> $150.00
City of Waterloo
WATERLOO���� � N���8����� FIRE RESCUE ~\ /
INSPECTION REPORT
BIG WO ODS PROPER TY0OLDINGS L&C RENTAL,2223 FALLS AVE, WA TERi00645070Y
DETAILS
Inspection|nspeocion Date: 10/24/2022 1 Inspection Type: Rental Inspection I Inspection Number: 8873 1 Shift: N/A | Station: N/A )
Unit: N/A Lead Inspector:BARRY5TRxTT0N Other Inspectors: N/A | Fee:$15O.O�J/
m�
�,~�-
STATUS CODE DESCmxPr/ma/
FAIL 1010.1.9 Door operations Except as specifically permitted by this section,egress doors shall be readily
openable from the egress side without the use of a key or special knowledge or
effort.
Inspector:BARRYSTRATTON Comments:Doors and door hardware need to be in
working conditions
FAIL 605.1 Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: 8ARRYSTKATTON Comments:Outlets not in working condition inliving
room and bedrooms.Outside lights do not work.Some outlets in house need
replaced because of tension strength issues. Electric in garage has extension cords
plugged into multi adapter.
FAIL e06.1 Where required Portable fire extinguishers shall be installed in all of the following locations: 1. in new
and existing Group A, B' E' F, n. |' K4. R'1' R'2' R-4and 6occupancies. Exception: In
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of1,A:10'B:[.2.Within 30 feet(0144mm)
of commercial cooking equipment.3. In areas where flammable or combustible
liquids are stored, used or dispensed.4.On each floor nf structures under
construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5.
Where required by the sections indicated in Table 906.1.0.Special-hazard areas'
including but not limited to laboratories, computer rooms and generator rooms,
where required by the fire code official.
Inspector: BARRvSTRATTON Comments:
F/l|L 007.2.11 Single-and Listed single'and multiple-station smoke alarms complying with UL 217 shall be
mu|tip|estationsnnoke installed in accordance with Sections yO7.2.11.1 through 907.2.11.6 and wFP^72.
alarms
Inspector-: BARKvSTRATTUN Comments:Smoke detectors needed in each bedroom,
outside bedrooms, and inbasement.
Printed""1o.124iz02z�``,_^
Pmoe1oro
" ~
STATUS CODE DESCAIPTION `
FAIL 9151 -General Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed it)
existing buildings in accordance with Section 1103.g.
Inspector: BARRvITRATTON Comments:[O detector needed in vicinity of
bedrooms.All need tobein working condition.
FAIL n5 ExreriorItruccure |s the exterior of the scructure maincained in good repair' structurally Sound and
sanitary state?(|PK4C 304)
Inspector:BARRYSTRATTON Comments:Rotten window sill on living room window
on West side of house. Replace sill plate to window.Screen door hardware.
FAIL R6 Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally Sound,and in a sanitary condition?(|PrNC 305)
Inspector: BARRvSTRATTON Comments: Mold in basement. Back door dead bolt is
not functional.Sink faucet needs replaced.Tub does not drain. Flooring in closet.
Toilet double flushes. Door hardware on screen door needs replaced. Peeling and
abraded paint on basernent walls needs to be corrected.Water damage on walls
under paint.
FAIL R6A. Interior Structure- Were any Unsafe conditions noted during the interior i,15JDeCd0n?(1PMC 305.1.1)
Unsafe Conditions
Inspector: BARRvSTRATTON [omments:Potential mo|dinbasennenc.
sawrmuL worE S
BxRRvSTRATTOw 10/24/2022{� 13:22 304.15 Doors. Exterior doors,door assemblies,operator systems if provided,and
hardware shall be maintained in good condition. Locks at all entrances to dwelling
units and sleeping units shall tightly secure the door. Locks on means of egress doors
shall bein accordance with Section 7U2.3.
BARRYSTRATTON 10/24/2022@13:22 304.18Bui|ding security. Doors,windows or hatchways for dwelling units, room units
or housekeeping units shall be provided with devices designed to provide security for
the occupants and property within
BARRYSTRATTON 10/24/2Dz2 Cal 13:23 305.3 Interior Surfaces. Interior surfaces,including windows and doors,shall be
maintained in good,clean and sanitary condition. Peeling,chipping,flaking or abraded
paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood
and other defective surface conditions shall becorrected.
Printed""1a/z4/20z,0a`a.24
GENERAL NOTES
`
8ARRvSTRATTON 10/24/2022@p13:23 5O41GeneeiPlumbing fixtures shall be properly installed and maintained inworking
order,and shall be kept free from obstructions, leaks and defects and be capable of
performing the function for which such plumbing fixzunes are designed. Plumbing
fixtures shall be maintained in a safe'sanitary and functional condition.
BARRvSTRATTON 10/24/2022@1323 605.1 Installation. Electrical equipment,wiring and appliances shall be properly
ins,a||ed and maintained ina safe and approved manner.
BARRYSTRA7TON 18/24/2022@13:23 304.13 Window,skylight and door frames. Every window,skylight,door and frame shall
be kept in sound condition,good repair and weather tight
BARRYSTRATTON 10/24/2022@13:24 Q'18'2483.6: Mold Present|nARental Unit.a.When mold is found robp visibly present
in small amounts, it can be cleaned in a safe and sanitary manner. b.When mold is
found in a rental unit and is determined to be a health risk,the building official may
order that a clean air report be obtained from a mold specialist approved by the
building official.
Rr/mSPeCr/ommArr
11/2fv2O22
CONTACT SIGNATURE
Big Woods Property Holdings
Signed on: 10/24/2022@13:24
INSPECTOR SIGNATURE
BARRYSTRATTON
Signed on: 10/24/2022@ 13:24
QUESTIONS ABOUT YOUR INSPECTION?
eARRYSTRATTON
barry.strauon@watedoo'ia.ong
(319)231'9147