Loading...
HomeMy WebLinkAbout1738 FLOWER ST #2 INVOICE DATE DUE DATE INVOICE# TOTAL DUE it�r11�i\��i•� 02/13/2023 03/20/2023 2023-00020350 $250.00 ���iit I °it°rloo �o Customer#: 10811 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable DOMINIC TANGEN 715 Mulberry St 2501 SCENIC DR WATERLOO, IA 50703 CEDAR FALLS, IA 50613 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION- 1738 FLOWER ST#2 - 12-9-22 FOR BILLING INQUIRY: (319)291-4323 5TH FAILED RE-INSPECTION Description I Total Price J REINSPECTION FEE 3RD $250.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 10811 02/13/2023 03/20/2023 2023-00020350 $250.00 Less Prepayment $0.00 Total Due—* $250.00 City of Waterloo WATERLOO FIRE RESCUE �YER(QO INSPECTION REPORT lI DOMINIC TANGEN RENTAL 8-PLEX, 1738 FLOWER ST, WATERLOO IA S0701 DETAILS Inspection Date: 12/09/2022 ( Inspection Type: Rental Inspection I Inspection Number:9089 Shift: N/A Station: N/A R Unit: N/A I Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$250.00 // �p �`4/ STATUS CODE DESCRIPTION FAIL 1013.3-Illumination Exit signs shall be internally or externally illuminated. Exception:Tactile signs required by Section 1013.4 need not be provided with illumination. Inspector:BARRY STRATTON-Comments:Egress/exit lights FAIL 1025.5-Illumination Where photoluminescent exit path markings are installed,they shall be provided with not less than 1 footcandle(11 lux)of illumination for not less than 60 minutes prior to periods when the building is occupied and continuously during the building occupancy. Inspector: BARRY STRATTON-Comments: FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector: BARRY STRATTON-Comments:Outlets missing and wire being scrapped from building FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON-Comments: Printed on 12109i2022- _._ Page 1 of 4 STATUS CODE DESCRIPTION FAIL 703.2-Opening protectives Opening protectives shall be maintained in an operative condition in accordance with NFPA 80.Where allowed by the fire code official,the application of field-applied labels associated with the maintenance of opening protectives shall follow the requirements of the approved third-party certification organization accredited for listing the opening protective. Fire doors and smoke barrier doors shall not be blocked or obstructed,or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged. Fire door assemblies shall not be modified. Inspector: BARRY STRATTON-Comments:Alarm testing and maintenance has still not been done. FAIL 901.6-Inspection,testing and Fire detection,alarm,and extinguishing systems,mechanical smoke exhaust maintenance systems,and smoke and heat vents shall be maintained in an operative condition at all times,and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected,tested and maintained or removed. Inspector: BARRY STRATTON-Comments: FAIL 901.6.1 -Standards Fire protection systems shall be inspected,tested and maintained in accordance with the referenced standards listed in Table. Inspector: BARRY STRATTON-Comments: FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A,B, E, F, H, I,M,R-1, R-2, R-4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3. In areas where flammable or combustible liquids are stored, used or dispensed.4. On each floor of structures under construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Inspector: BARRY STRATTON-Comments: FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector: BARRY STRATTON-Comments: Detectors missing throughout building and all apartments. printed,- Page 2 of 4 STATUS CODE DESCRIPTION FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may include boilers, heating equipment,elevator,moving stairways,electrical wiring,and flammable liquid containers.(IPMC 108.1.2) Inspector: BARRY STRATTON-Comments:All units are uninhabitable. Building does not meet fire safety and rental requirements. FAIL R3-Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPMC Occupancy 108.1.3) Inspector: BARRY STRATTON-Comments:Apartments 1-8 FAIL R4- Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This includes grading and drainage,sidewalks and driveways,weeds,and pest infestations.(IPMC 302) Inspector: BARRY STRATTON-Comments: Debris FAIL R5-Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and sanitary state?(IPMC 304) Inspector: BARRY STRATTON-Comments:Windows,doors, electrical FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound, and in a sanitary condition?(IPMC 305) Inspector: BARRY STRATTON-Comments:All units 1-8 unfit to occupy FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions Inspector: BARRY STRATTON-Comments: FAIL R6.B.- Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F?(IPMC 602.2) Inspector:BARRY STRATTON -Comments: FAIL R6.C.- Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition?(IPMC 603.1) Inspector:BARRY STRATTON -Comments: Printed on 12fC Page 3 of 4 GENERAL NOTES BARRY STRATTON-12/09/2022 @ 06:37 Units 1-8 BARRY STRATTON-12/09/2022 @ 06:38 Report Unit#2 REINSPECTION DATE 01/10/2023 CONTACT SIGNATURE Dominic Tangen Signed on: 12/09/2022 @ 06:38 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 12/09/2022 @ 06:38 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Printed on 12/09/2022 06.39 Page 4 of 4