Loading...
HomeMy WebLinkAbout1420 GRANT AVE INVOICE DATE DUE DATE INVOICE# TOTAL DUE /(7,aPM Ir;.; 02/13/2023 03/20/2023 2023-00020351 $150.00 %rloo Customer#: 8231 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable ROGER/SHIRLEY CURRAN 715 Mulberry St 1001 PROSPECT BL WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 1420 GRANT AVE- 12-14-22 FOR BILLING INQUIRY: (319)291-4323 Description ( Total Price REINSPECTION FEE 2ND $150.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 8231 02/13/2023 03/20/2023 2023-00020351 $150.00 Less Prepayment $0.00 Total Due—> $150.00 City of Waterloo WATERLOO FIRE RESCUE 44,1 i° II . INSPECTION REPORT " ?) SHIRLEY CURRAN 5 UNIT RENTAL, 1420 GRANT AVE, WATERLOO IA 50702 ` �RE�>� DETAILS Inspection Date: 12/14/2022 1 Inspection Type: Rental Inspection I Inspection Number:7971 i Shift: N/A Station: N/A I Unit: N/A j Lead Inspector:BARRY STRATTON I Other Inspectors: N/A 1 Fee:$150.00 f , ," _ Ate? STATUS CODE DESCRIPTION FAIL 1010.1.9-Door operations Except as specifically permitted by this section,egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON-Comments: FAIL 1018.1 -General Aisles and aisle accessways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section.Aisles or aisle accessways shall be provided from all occupied portions of the exit access that contain seats,tables,furnishings,displays and similar fixtures or equipment.The minimum width or required capacity of aisles shall be unobstructed. Exception: Encroachments complying with Section 1005.7. Inspector: BARRY STRATTON-Comments: FAIL 505.1 -Address identification New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property.Address identification characters shall contrast with their background.Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches(102 mm)high with a minimum stroke width of 1/2(12.7 mm). Where required by the fire code official,address identification shall be provided in additional approved locations to facilitate emergency response.Where access is by means of a private road and the building cannot be viewed from the public way,a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Inspector: BARRY STRATTON-Comments:Need apartment numbers on all apartment doors. FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON -Comments: 13114 Page 1 of 3 S L STATUS COOE DESCRIPTION FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector:BARRY STRATTON-Comments:Smoke detectors need to be installed to meet code requirements. FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector: BARRY STRATTON-Comments: FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may include boilers,heating equipment, elevator, moving stairways,electrical wiring,and flammable liquid containers.(IPMC 108.1.2) Inspector: BARRY STRATTON-Comments:Water leak,furnace and rear stairs to Unit 5.(Currently no stairs on rear of apartment 5) FAIL R4-Exterior Property Areas Is the exterior property area maintained in a clean, safe,and sanitary condition?This includes grading and drainage,sidewalks and driveways,weeds,and pest infestations.(IPMC 302) Inspector: BARRY STRATTON-Comments:Rear stairs to Unit 5 still not corrected. FAIL R5- Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and sanitary state?(IPMC 304) Inspector: BARRY STRATTON-Comments:No Rear stairs to unit 5 FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector:BARRY STRATTON-Comments: FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F?(IPMC 602.2) Inspector: BARRY STRATTON-Comments:Furnace ducts in basement GENERAL NOTES P<r rted on 12f14,2O22`:13:14 Page 2 of 3 II • BARRY STRATTON-12/14/2022 @ 13:13 Initial Notice given January 2022 REINSPECTION DATE 01/13/2023 CONTACT SIGNATURE Shirley Curran Signed on:12/14/2022 @ 13:13 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 12/14/2022 @ 13:14 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Printed on 12/14.20271. 13:14 Page 3 of 3