Loading...
HomeMy WebLinkAbout1121 LOCKE AVE INVOICE DATE DUE DATE INVOICE# TOTAL DUE //(4i 411, ter.:; 02/13/2023 03/20/2023 2023-00020353 $150.00 4'4erloo �o Customer#: 14761 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable SCOTTQ KIPP 715 Mulberry St 2617 VIKING RD WATERLOO, IA 50703 CEDAR FALLS, IA 50613 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION- 1121 LOCKE AVE- 10-24-22 FOR BILLING INQUIRY: (319)291-4323 L Description I Total Price REINSPECTION FEE 2ND $150.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 14761 02/13/2023 03/20/2023 2023-00020353 $150.00 Less Prepayment $0.00 Total Due— $150.00 City of Waterloo WATERLOO FIRE RESCUE INSPECTION REPORT SCOTT KIPP SINGLE FAMILY RENTAL, 1121 LOCKEAVE, WATERLOO IA 50702 „ryf ' DETAILS Inspection Date: 10/24/2022 I Inspection Type: Rental Inspection I Inspection Number:8869 Shift: N/A I Station: N/A I Unit: N/A I Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$150.00 /, ,4141/ STATUS CODE DESCRIPTION FAIL 1010.1.9- Door operations Except as specifically permitted by this section,egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON-Comments:Screen door lock set does not secure door to lock catch. FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON-Comments: Need outlet covers on all outlets (basement). Extension cords need removed. Light at front door has broken globe still not fixed. FAIL 605.5- Extension cords Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings,nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Inspector:BARRY STRATTON-Comments: FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A,B, E, F, H,I,M,R-1,R-2, R-4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3. In areas where flammable or combustible liquids are stored,used or dispensed.4. On each floor of structures under construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. inspector: BARRY STRATTON-Comments: printed on 1O,24.i:-- = -Page 1 of 4 4 � v STATUS CODE DESCRIPTION FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UI-217 snail no multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector: BARRY STRATTON-Comments:Smoke detector missing.Need smoke detectors installed in each bedroom,outside bedrooms,and in basement. FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector:BARRY STRATTON-Comments:CO Detector is not working. FAIL R4- Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This includes grading and drainage,sidewalks and driveways,weeds,and pest infestations.(IPMC 302) Inspector: BARRY STRATTON-Comments:Front steps need replaced. Concrete is decayed and holes have formed from failure.Gutters need cleaned out and gutter extensions need to be installed.Still not done FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector:BARRY STRATTON-Comments:Tub surround needs replaced.Bathroom window has water damage and mold in forming on damaged wood. Bath fan need cleaned. Leak in foundation in basement needs repaired. Handrail is needed to basement. FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions Inspector: BARRY STRATTON-Comments:Mold FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F?(IPMC 602.2) Inspector:BARRY STRATTON-Comments:Leak under furnace. Possible condensate line plugged. FAIL R6.C.-Mechanical Ediupment Are mechanical appliances properly installed and maintained in good working condition?(IPMC 603.1) Inspector: BARRY STRATTON-Comments: Draft hood on water needs secured. Printed on 10/24/2022 4�13:12 Page 2 of 4 %A Wit GENERAL NOTES BARRY STRATTON-10/24/2022 a 13:09 304.5 Foundation walls. Foundation walls shall be maintained plumb and free from open cracks and breaks and shall be kept in such condition so as to prevent the entry of rodents and other pests.304.6 Exterior walls. Exterior walls shall be free from holes, breaks,and loose or rotting materials;and maintained weatherproof and properly surface coated where required to prevent deterioration.Standing water in basement needs corrected. BARRY STRATTON- 10/24/2022 @ 13:10 304.7 Roofs and drainage.The roof and flashing shall be sound,tight and not have defects that admit rain. Roof drainage shall be adequate to prevent dampness or deterioration in the walls or interior portion of the structure. Roof drains,gutters and downspouts shall be maintained in good repair and free from obstructions. Roof water shall not be discharged in a manner that creates a public nuisance. BARRY STRATTON-10/24/2022 6,13:10 304.12 Handrails and guards. Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition. BARRY STRATTON- 10/24/2022 @ 13:10 304.13 Window,skylight and door frames. Every window,skylight,door and frame shall be kept in sound condition,good repair and weather tight. BARRY STRATTON-10/24/2022 @ 13:10 304.15 Doors. Exterior doors, door assemblies,operator systems if provided,and hardware shall be maintained in good condition. Locks at all entrances to dwelling units and sleeping units shall tightly secure the door. Locks on means of egress doors shall be in accordance with Section 702.3. BARRY STRATTON-10/24/2022 @ 13:10 304.10 Stairways,decks,porches and balconies. Every exterior stairway,deck, porch and balcony,and all appurtenances attached thereto,shall be maintained structurally sound, in good repair,with proper anchorage and capable of supporting the imposed loads. BARRY STRATTON-10/24/2022 @ 13:10 601.2 Responsibility.The owner of the structure shall provide and maintain mechanical and electrical facilities and equipment in compliance with these requirements.A person shall not occupy as owner-occupant or permit another person to occupy any premises that does not comply with the requirements of this chapter.Condensate line possibly plugged on furnace. BARRY STRATTON-10/24/2022 @ 13:11 9-7-4 9-7-5: Rental registration is needed each year for rental units. Register listed address as a rental.Still not registered 2022 Printed on 10/24/2022 tr.13:12 Page 3 of 4 • REINSPECTION DATE 11/23/2022 CONTACT SIGNATURE Scott Kipp Signed on:10/24/2022 @ 13:11 A\/ IL INSPECTOR SIGNATURE BARRY STRATTON Signed on:10/24/2022 @ 13:11 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barrystratton@waterloo-ia.org (319)231-9147 P- Page 4 of 4