RENTAL INSPECTION - 204 MOIR- 12-14-22 FOR BILLING INQUIRY: (319)291-4323
Description I Total Price j
REINSPECTION FEE 2ND $150.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
8231 02/13/2023 03/20/2023 2023-00020354 $150.00
Less Prepayment $0.00
Total Due—* $150.00
City of Waterloo
3,7)(
WATERLOO FIRE RESCUE 4.1 %
INSPECTION REPORT
SHIRLEY CURRAN SINGLE FAMILY RENTAL, 204 MOIR ST, WATERLOO IA 50701 4410
DETAILS
Inspection Date: 12/14/2022 j Inspection Type: Rental Inspection I Inspection Number: 7897 I Shift: N/A Station: N/A =
Unit: N/A Lead Inspector:BARRY STRATTON j Other Inspectors: N/A Fee:$150.00 nn 4JIIS
ol
STATUS COPE DESCRIPTION
FAIL 1010.1.9-Door operations Except as specifically permitted by this section,egress doors shall be readily
openable from the egress side without the use of a key or special knowledge or
effort.
Inspector: BARRY STRATTON-Comments:Interior doors all need replaced.
FAIL 1031.7-Emergency escape Required emergency escape and rescue openings shall be maintained in accordance
and rescue openings with the code in effect at the time of construction,and the following: Required
emergency escape and rescue openings shall be operational from the inside of the
room without the use of keys or tools. Bars,grilles,grates or similar devices are
allowed to be placed over emergency escape and rescue openings provided the
minimum net clear opening size complies with the code that was in effect at the time
of construction and such devices shall be releasable or removable from the inside
without the use of a key,tool or force greater than that which is required for normal
operation of the emergency escape and rescue opening.
Inspector: BARRY STRATTON-Comments:304.13 Window,skylight and door frames.
Every window,skylight,door and frame shall be kept in sound condition,good repair
and weather tight.304.13.2 Openable windows. Every window,other than a fixed
window,shall be easily openable and capable of being held in position by window
hardware.304.14 Insect screens. During the period from[DATE]to[DATE],every door,
window and other outside opening required for ventilation of habitable rooms,food
preparation areas,food service areas or any areas where products to be included or
utilized in food for human consumption are processed, manufactured, packaged or
stored shall be supplied with approved tightly fining screens of minimum 16 mesh
per inch(16 mesh per 25 mm),and every screen door used for insect control shall
have a self-closing device in good working condition.
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector:BARRY STRATTON-Comments:Electric not working in basement, missing
outlet covers,lights in basement do not work. Globes needed on all light fixtures.
-:ed on 12J14d2022_ `_:05
Page 1 of 4
STATUS CODE DESCRIPTION
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new
and existing Group A, B,E, F, H, I, M, R-1,R-2, R-4 and S occupancies. Exception: In
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm)
of commercial cooking equipment.3. In areas where flammable or combustible
liquids are stored, used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas,
including but not limited to laboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector: BARRY STRATTON-Comments:
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector: BARRY STRATTON-Comments:Smoke detectors needed in each bedroom,
outside of bedroom,and in basement.All detectors shall be in working condition.
FAIL 915.1 -Genera Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector:BARRY STRATTON-Comments:
FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may
include boilers, heating equipment,elevator,moving stairways,electrical wiring,and
flammable liquid containers.(IPMC 108.1.2)
Inspector: BARRY STRATTON-Comments:Water heater has no drip leg.
FAIL R3- Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPMC
Occupancy 108.1.3)
Inspector: BARRY STRATTON-Comments: 111.1.3 Structure unfit for human
occupancy.A structure is unfit for human occupancy whenever the code official finds
that such structure is unsafe, unlawful or,because of the degree to which the
structure is in disrepair or lacks maintenance, is insanitary,vermin or rat infested,
contains filth and contamination,or lacks ventilation,illumination,sanitary or heating
facilities or other essential equipment required by this code,or because the location
of the structure constitutes a hazard to the occupants of the structure or to the
public.(New tenants at listed address and corrections not inspected before
occupancy.
Page 2 of 4
STATUS CODE DESCRIPTION
FAIL R4- Exterior Property Areas Is the exterior property area maintained in a clean,safe, and sanitary condition?This
includes grading and drainage,sidewalks and driveways,weeds,and pest
infestations.(IPMC 302)
Inspector: BARRY STRATTON-Comments:Hole in rear yard needs filled in.
FAIL R5- Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and
sanitary state?(1PMC 304)
Inspector:BARRY STRATTON-Comments:Doors,windows,no screens,and roof
needs replaced. Rotten sofit needs replaced.(Roof&Sofit still not done). House has
needed a new roof for along time.
FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector: BARRY STRATTON-Comments: Front&rear doors,all windows need locks
and capable of opening and closing.Stove not working. No window screens.
Handrails loose on stairs to upstairs and are not installed to code because handrail is
to small.Window frames and door jambs rotten. Doors and windows shall be
weather tight. Bathroom sink faucet needs replaced.Toilet needs re-set on floor,
bathroom floor and sub floor needs replaced. Kitchen ceiling needs replaced.Sun
porch ceiling is falling in. Peeling paint needs corrected. Bedroom ceiling needs
repaired.Carpet on steps is torn. Plastic pipe in kitchen ceiling not to code.
FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector: BARRY STRATTON-Comments:
FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room
temperature of 68F?(IPMC 602.2)
Inspector: BARRY STRATTON-Comments:
FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector: BARRY STRATTON-Comments:NO drip leg on water heater. have licensed
contractor make corrections.
GENERAL NOTES
BARRY STRATTON-12/14/2022 @ 13:05 Initial Notice given March 18th,2022
Printed on 12/14/2022;g 13:06
Page 3 of 4
REINSPECT1ON DATE
01/13/2023
CONTACT SIGNATURE
Shirley Curran Ak
Signed on: 12/14/2022 @ 13:05
INSPECTOR SIGNATURE
BARRY STRATTON 2
Signed on: 12/14/2022 @ 13:06