Loading...
HomeMy WebLinkAbout915 W 5TH ST ��.� INVOICE DATE DUE DATE INVOICE# TOTAL DUE /�,'1� ak, kr:4 02/13/2023 03/20/2023 2023-00020359 $50.00 ""erloo \o Customer#: 23946 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable ESHAN ASLAM 715 Mulberry St 919 W 5TH ST WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION- 915 W 5TH ST- 10-25-22 FOR BILLING INQUIRY: (319)291-4323 1_Description I Total Price REINSPECTION FEE 1ST $50.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23946 02/13/2023 03/20/2023 2023-00020359 $50.00 Less Prepayment $0.00 Total Due --> $50.00 City of Waterloo WATERLOO FIRE RESCUE INSPECTION REPORT EHSAN ASLAM UPPER/LOWER RENTAL DUPLEX, 915 W STH ST, WATERLOO IA 50702 of RE > DETAILS Inspection Date: 10/25/2022 I Inspection Type: Rental Inspection ? Inspection Number:8893 I Shift: N/A ( Station: N/A t Unit: N/A I Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$50.00 4/4/4 1 -74 STATUS CODE DESCRIPTION t Al L 1010.1.9- Door operations Except as specifically permitted by this section,egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON-Comments:Door to apartment# 1 will need replaced. No proper door hardware installed on door. FAIL 1031.2- Reliability Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector: BARRY STRATTON-Comments: FAIL 506.1 -Where required Where access to or within a structure or an area is restricted because of secured openings or where immediate access is necessary for life-saving or fire-fighting purposes,the fire code official is authorized to require a key box to be installed in an approved location.The key box shall be of an approved type listed in accordance with UL 1037,and shall contain keys to gain necessary access as required by the fire code official. Inspector: BARRY STRATTON-Comments:If building is to remain secure a Knox box will be required to be installed on building. FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON-Comments:Exposed wires above panel in basement. Extension cords need removed. Printed on 10 2E - Page 1 of 5 STATUS CODE DESCRIPTION FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3. In areas where flammable or combustible liquids are stored,used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Inspector: BARRY STRATTON-Comments: FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector:BARRY STRATTON-Comments:Smoke detectors will need installed to meet code requirements. FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector: BARRY STRATTON-Comments: FAIL R4-Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This includes grading and drainage,sidewalks and driveways,weeds,and pest infestations.(IPMC 302) Inspector: BARRY STRATTON- Comments: Rear stairs will need to be moved closer to house. FAIL R5- Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and sanitary state?(IPMC 304) Inspector: BARRY STRATTON-Comments:Front deck and supports need repaired. FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector: BARRY STRATTON-Comments:Building security,toilet does not flush, Shower, bath sink mounting, Medicine cabinet mounting, No stove to cook, kitchen floor needs replaced. Prated on 10/25/2022 31 Page 2 of 5 STATUS CODE DESCRIPTION FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F?(IPMC 602.2) Inspector: BARRY STRATTON-Comments:Thermostat in basement without access of tenants to building GENERAL NOTES BARRY STRATTON-10/25/2022 @ 06:28 304.10 Stairways,decks,porches and balconies. Every exterior stairway,deck, porch and balcony,and all appurtenances attached thereto,shall be maintained structurally sound, in good repair,with proper anchorage and capable of supporting the imposed loads. BARRY STRATTON-10/25/2022 @ 06:28 304.18 Building security. Doors,windows or hatchways for dwelling units, room units or housekeeping units shall be provided with devices designed to provide security for the occupants and property within. BARRY STRATTON-10/25/2022 @ 06:28 304.18.1 Doors. Doors providing access to a dwelling unit, rooming unit or housekeeping unit that is rented,leased or let shall be equipped with a deadbolt lock designed to be readily openable from the side from which egress is to be made without the need for keys,special knowledge or effort and shall have a minimum lock throw of 1 inch(25 mm).Such deadbolt locks shall be installed according to the manufacturer's specifications and maintained in good working order. For the purpose of this section,a sliding bolt shall not be considered an acceptable deadbolt lock. BARRY STRATTON-10/25/2022 @ 06:29 305.1 General.The interior of a structure and equipment therein shall be maintained in good repair, structurally sound and in a sanitary condition.Occupants shall keep that part of the structure that they occupy or control in a clean and sanitary condition. Every owner of a structure containing a rooming house, housekeeping units,a hotel,a dormitory,two or more dwelling units or two or more nonresidential occupancies, shall maintain,in a clean and sanitary condition,the shared or public areas of the structure and exterior property. BARRY STRATTON 10/25/2022 @ 06:29 305.3 Interior surfaces. Interior surfaces,including windows and doors,shall be maintained in good,clean and sanitary condition. Peeling,chipping,flaking or abraded paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected. BARRY STRATTON-10/25/2022 @ 06:29 305.4 Stairs and walking surfaces. Every stair,ramp,landing,balcony,porch,deck or other walking surface shall be maintained in sound condition and good repair. Panted on 10/25 2022 t 05:31 Page 3 of 5 GENERAL NOTES BARRY STRATTON-10/25/2022 @ 06:29 404.7 Food preparation.Spaces to be occupied for food preparation purposes shall contain suitable space and equipment to store,prepare and serve foods in a sanitary manner.There shall be adequate facilities and services for the sanitary disposal of food wastes and refuse,including facilities for temporary storage BARRY STRATTON-10/25/2022 @ 06:29 504.1 General. Plumbing fixtures shall be properly installed and maintained in working order,and shall be kept free from obstructions,leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. Plumbing fixtures shall be maintained in a safe, sanitary and functional condition.Toilet does not flush and toilet in 615 1/2 Apartment does not work. BARRY STRATTON- 10/25/2022 @ 06:30 505.1 General. Every sink,lavatory,bathtub or shower,drinking fountain,water closet or other plumbing fixture shall be properly connected to either a public water system or to an approved private water system. Kitchen sinks,lavatories,laundry facilities, bathtubs and showers shall be supplied with hot or tempered and cold running water in accordance with the Plumbing Code. PVC s installed between cast pipe and done without permits. Low Dollar installed without permits and inspections. BARRY STRATTON- 10/25/2022 @ 06:30 05.3 Supply.The water supply system shall be installed and maintained to provide a supply of water to plumbing fixtures,devices and appurtenances in sufficient volume and at pressures adequate to enable the fixtures to function properly,safely,and free from defects and leaks. BARRY STRATTON-10/25/2022 @ 06:30 Front deck and supports shall be maintained in good condition. REINSPECTION DATE 11/28/2022 CONTACT SIGNATURE Ehsan Aslam Signed on:10/25/2022 @ 06:30 ANAA INSPECTOR SIGNATURE BARRY STRATTON Signed on:10/25/2022 @ 06:31 Printed on 10/25/2022 t 05:31 Page 4 of 5 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 7 zed on 10/25/2022.1.06 31 Page 5 of 5