Loading...
HomeMy WebLinkAbout511 WILDWOOD RD INVOICE DATE DUE DATE INVOICE# TOTAL DUE ���\� . 02/08/2023 03/15/2023 2023-00020339 $50.00 kienee °1erloo No Customer#: 7059 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable LEMUR PROPERTIES 715 Mulberry St 3121 BROCKWAY RD WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 511 WILDWOOD RD - 12-19-22 FOR BILLING INQUIRY: (319)291-4323 P L Description I Total Price J REINSPECTION FEE 1ST $50.00 CUSTOMER# BILLING DATE DUE DATE 20 INVOICE # CHARGES $50.00 7059 02/08/2023 03/15/2023 Less Prepayment $0.00 Total Due $50.00 City of Waterloo .i�pYf H(pU.. WATERLOO FIRE RESCUE Q INSPECTION REPORT ` LEMUR PROPERTIES.MULTI-PLEX, 5?1 WILDWOOD RD, WATERLOO IA 50702 1 3ILtR.d DETAILS 'OC , • Inspection Date: 12/19/2022 1 Inspection Type: Rental Inspection j Inspection Number:9205 1 Shift: N/A I Station: N/A Unit: N/A ! Lead Inspector:BARRY STRATTON i Other Inspectors: N/A j Fee:$50.00 75r/'/7/ i'?9 STATUS CODE - DESCRIPTION FAIL 1008.2-Illumination required The means of egress serving a room or space shall be illuminated at all times that the room or space is occupied. Exceptions: 1.Occupancies in Group U.2.Aisle accessways in Group A.3. Dwelling units and sleeping units in Groups R-1,R-2 and R- 3.4.Sleeping units of Group I occupancies. Inspector: BARRY STRATTON-Comments:Light missing in hallway in laundry room. FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector: BARRY STRATTON-Comments: Frame around door to unit# 1 is missing. FAIL 506.1 -Where required Where access to or within a structure or an area is restricted because of secured openings or where immediate access is necessary for life-saving or fire-fighting purposes,the fire code official is authorized to require a key box to be installed in an approved location.The key box shall be of an approved type listed in accordance with UL 1037,and shall contain keys to gain necessary access as required by the fire code official. Inspector:BARRY STRATTON-Comments:Need a knox box on exterior of building for fire department access in case of medical emergency. FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:BARRY STRATTON-Comments:Water heater wiring needs to be in EMT (ridged pipe). P,rated on 12,1912022 g'4:23 Page 1 of 3 STATUS CODE DESCRIPTION FAiL 703.1 -Maintenance The required fire-resistance rating of fire-resistance-rated construction,including, but not limited to,walls,firestops,shaft enclosures, partitions,smoke barriers, floors,fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems,shall be maintained.Such elements shall be visually inspected by the owner annually and properly repaired, restored or replaced where damaged,altered, breached or penetrated. Records of inspections and repairs shall be maintained.Where concealed,such elements shall not be required to be visually inspected by the owner unless the concealed space is accessible by the removal or movement of a panel,access door,ceiling tile or similar movable entry to the space.Openings made therein for the passage of pipes, electrical conduit,wires,ducts,air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire.Openings through fire-resistance-rated assemblies shall be protected by self-or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Inspector: BARRY STRATTON-Comments:Open chases in Walls in basement need covered up.Ceiling tiles missing and ceiling tiles damaged need replaced. FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.E and NFPA 72. alarms Inspector: BARRY STRATTON-Comments:Smoke detectors needed in basement laundry area. FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector: BARRY STRATTON-Comments:Front window is not weather tight.All weather striping and seals rotten.Window moves in track allowing air to come into apartment. FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition?(IPMC 603.1) { Inspector: BARRY STRATTON-Comments:Water heater in Unit# 1 needs wiring in ridged pipe. REINSPECTION DATE 01/17/2023 Printed on 12 _022 ie 14:23 Page 2 of 3 CONTACT SIGNATURE Lemur Properties ELTik_ Signed on:12/19/2022 @ 14:27 INSPECTOR SIGNATURE BARRY STRATTON — Signed on:12/19/2022 @ 14:27 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@watertoo-ia.org (319)231-9147 Printed on 1211912022 14:2Z Page 3 of 3