RENTAL INSPECTION- 1411 W 6TH ST- 1-13-23 FOR BILLING INQUIRY: (319)291-4323
L Description Total Price
REINSPECTION FEE 3RD $250.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
12490 02/08/2023 03/15/2023 2023-00020341 $250.00
Less Prepayment $0.00
Total Due $250.00
City of Waterloo
WATERLOO FIRE RESCUE LAO .„N L .0
INSPECTION REPORT
METRO INVESTMENTS EAST LLC, 1411 W 6TH ST, WATERLOO IA 50702
DETAILS
Inspection Date:01/13/2023 I Inspection Type: Rental Inspection j Inspection Number:9151 I Shift: N/A I Station: N/A
Unit: N/A I Lead Inspector:BARRY STRATTON R Other Inspectors: N/A I Fee:$250.00
Aihik
: '
STATUS CODE DESCRIPTION
FAIL 1031.7-Emergency escape Required emergency escape and rescue openings shall be maintained in accordance
and rescue openings with the code in effect at the time of construction,and the following: Required
emergency escape and rescue openings shall be operational from the inside of the
room without the use of keys or tools. Bars,grilles,grates or similar devices are
allowed to be placed over emergency escape and rescue openings provided the
minimum net clear opening size complies with the code that was in effect at the time
of construction and such devices shall be releasable or removable from the inside
without the use of a key,tool or force greater than that which is required for normal
operation of the emergency escape and rescue opening.
Inspector:BARRY STRATTON-Comments:Broken Windows
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1.In new
and existing Group A, B,E, F, H,I, M,R-1,R-2,R-4 and S occupancies. Exception: In
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A:10-B:C.2.Within 30 feet(9144 mm)
of commercial cooking equipment.3. In areas where flammable or combustible
liquids are stored, used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies,in accordance with Section 3315.1.5.
Where required by the sections indicated in Table 906.1.6. Special-hazard areas,
including but not limited to laboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector:BARRY STRATTON -Comments:
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2,11,6. and NEPA 72.
alarms
Inspector:BARRY STRATTON-Comments:
FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may
include boilers,heating equipment,elevator,moving stairways,electrical wiring,and
flammable liquid containers.(IPMC 108.1.2)
Inspector: BARRY STRATTON-Comments:Sanitary drain pipe in basement
Pinted on O,13,2023 is 12:43
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL R4-Exterior Property Areas Is the exterior property area maintained in a dean,safe,and sanitary condition?This
includes grading and drainage,sidewalks and driveways,weeds,and pest
infestations.(IPMC 302)
Inspector:BARRY STRATTON-Comments:Water getting into basement from
foundation deficiencies
FAIL R5-Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and
sanitary state?(IPMC 304)
Inspector: BARRY STRATTON-Comments:Foundation
FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector:BARRY STRATTON-Comments:Several leaks in basement.Leaks from
foundation. Plumbing leaks and water valve for outside faucet is leaking into
basement.Shower leaking into basement through floor.Water leaking onto
bathroom floor from shower.Need handrails to upstairs. Broken windows upstairs
need fixed.Sewer gas smell in basement.Drain pipe in basement not secured to
code.Wire hanger rapped around electric conduit not allowed. Drain pipe appears to
go nowhere. Floor in bathroom need repaired from water damage.Ceiling in
basement under bathroom damaged from water.Bedroom wall paneling pulling
away from wall needs repaired.The kitchen sink drainage issues.
FAIL Rb.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector: BARRY STRATTON-Comments:Potential mold formation from water leaks.
Mold on upstairs walls from water damage.
GENERAL NOTES
BARRY STRATTON-01/13/2023 n 12:48 Inspection is 1 year and 3 months old,
REINSPECTION DATE
02/10/2023
CONTACT SIGNATURE
Metro Investments LLC ~ UV11�
Signed on:01/13/2023 @ 12:48