Loading...
HomeMy WebLinkAbout210 INDEPENDENCE AVE INVOICE DATE DUE DATE INVOICE# TOTAL DUE i �� �ik, 02/08/2023 03/15/2023 2023-00020333 $250.00 oilassoop pr.- .IA=- '-.77:--;t1 Customer#: 24033 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable IA INVESTMENT PROPERTY 715 Mulberry St 5001 1ST AVE SE SUITE 105,221 WATERLOO, IA 50703 CEDAR RAPIDS, IA 52402 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION- 210 INDEPENDENCE AVE- 12-29-22 FOR BILLING INQUIRY: (319)291-4323 [Description I Total Price REINSPECTION FEE 3RD $250.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24033 02/08/2023 03/15/2023 2023-00020333 $250.00 Less Prepayment $0.00 Total Due-- $250.00 City of Waterloo WATERLOO FIRE RESCUE �P� L4o INSPECTION REPORT % QUALI ONCRETE CONSTRUCTION MULTI UNIT COMPLEX,210 INDEPENDENCE AVE, stIRA,;,.* , WATERLOO IA S0703 DETAILS 1 9 11/4 ra h,A* Inspection Date:12/29/2022 I Inspection Type: Rental Inspection I inspection Number:9060 I Shift: N/A I Station: N/A f Unit: N/A I Lead Inspector:BARRY STRATTON l Other Inspectors: N/A I Fee:$25 `/ f/el tt lPl STATUS CODE DESCRIPTION FAIL 1010.1.9-Door operations Except as specifically permitted by this section,egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector:BARRY STRATTON-Comments: FAIL 1031.7-Emergency escape Required emergency escape and rescue openings shall be maintained in accordance and rescue openings with the code in effect at the time of construction,and the following:Required emergency escape and rescue openings shall be operational from the inside of the • room without the use of keys or tools.Bars,grilles,grates or similar devices are allowed to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of a key,tool or force greater than that which is required for normal operation of the emergency escape and rescue opening. Inspector:BARRY STRATTON-Comments:Windows need to open and dose FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:BARRY STRATTON-Comments:Globes missing on lights FAIL 605.5-Extension cords Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall \JrC‘ be used only with portable appliances. (\\` /si \/j'c\VV'') inspector: BARRY STRATTON-Comments: 0 Printed on 12/29/2022 10:57 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A,B,E,F, H,I, M,R-1,R-2,R-4 and S occupancies. Exception: In Group R-2 occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3. In areas where flammable or combustible liquids are stored,used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies,in accordance with Section 3315.1.5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories,computer rooms and generator rooms, where required by the fire code official. Inspector: BARRY STRATTON-Comments: FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector:BARRY STRATTON-Comments:Smoke detectors needed in ail bedrooms, outside all bedrooms,on all levels,and in basement. FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector:BARRY STRATTON-Comments:CO detectors needed in vicinity of bedrooms. FAIL R4- Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This includes grading and drainage,sidewalks and driveways,weeds,and pest infestations.(IPMC 302) Inspector:BARRY STRATTON-Comments:Junk and debris FAI L R5- Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and sanitary state?(IPMC 304) Inspector:BARRY STRATTON-Comments:Handrails do not meet code front steps and concrete steps on building need replaced. FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Printed on" _ _._ •- Page 2 of 3 STATUS CODE DESCRIPTION Inspector:BARRY STRATTON-Comments:Kitchen&Dining room ceilings have water damage.Remove all water damaged material and replace.Cockroaches need exterminated.Kitchen floor needs replaced.Windows need to be capable of opening and closing.Front door and screen door need repaired and be capable of closing and latching.Toilet need re-set on bathroom floor.Stove needs replaced.Kids bedroom ceiling has holes that need corrected. Need handrails on stairs to upstairs and basement stairs.Glass all over inside apartment. .. R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition?(1PMC 603.1) Inspector:BARRY STRATTON-Comments:Water heater need discharge tube installed. REINSPECTION DATE 0 1/24/2023 CONTACT SIGNATURE Joyce Wood Signed on:12/29/2022 @ 10:56 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 12/29/2022 @ 10:56 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Painted on 12129/2022 g%10:57 Page 3 of 3