RENTAL INSPECTION- 1121 LOCKE AVE- 12-21-22 FOR BILLING INQUIRY: (319)291-4323
LDescriptidn Total Price
REINSPECTION FEE 3RD $250.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
23945 02/08/2023 03/15/2023 2023-00020334 $250.00
Less Prepayment $0.00
Total Due $250.00
City of Waterloo
WATERLOO FIRE RESCUE
INSPECTION REPORT
SCOTT KIPP SINGLE FAMILY RENTAL, 1121 LOCKE AVE, WATERLOO IA$0702 Tekio
DETAILS
Inspection Date: 12/21/2022 I Inspection Type: Rental Inspection I Inspection Number:9234 I Shift: N/A I Station: N/A
Unit: N/A I Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$250.00 /_ SA
STATUS CODE DESCRIPTION
FAIL 1010.1.9-Door operations Except as specifically permitted by this section,egress doors shall be readily
openable from the egress side without the use of a key or special knowledge or
effort.
Inspector:BARRY STRATTON-Comments:Screen door lock set does not secure door
to lick catch
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector:BARRY STRATTON-Comments:Outlet covers needed on all outlets in
basement. Light at front door still not repaired.
FAIL 605.5-Extension cords Extension cords and flexible cords shall not be a substitute for permanent wiring.
Extension cords and flexible cords shall not be affixed to structures,extended
through walls,ceilings or floors,or under doors or floor coverings, nor shall such
cords be subject to environmental damage or physical impact.Extension cords shall
be used only with portable appliances.
Inspector: BARRY STRATTON-Comments:
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1.In new
and existing Group A,B,E, F, H,I, M,R-1,R-2,R-4 and S occupancies.Exception: In
Group R-2 occupancies,portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A:10-B:C.2.Within 30 feet(9144 mm)
of commercial cooking equipment.3.In areas where flammable or combustible
liquids are stored,used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies,in accordance with Section 3315.1.5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas,
including but not limited to laboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector: BARRY STRATTON-Comments:
_ - 2:47
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector: BARRY STRATTON-Comments:Need smoke detectors in all bedrooms,
outside bedrooms and in basement.
FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector:BARRY STRATTON-Comments:CO detectors need to be in working
condition.
FAIL R4- Exterior Property Areas is the exterior property area maintained in a clean,safe,and sanitary condition?This
includes grading and drainage,sidewalks and driveways,weeds,and pest
infestations.(IPMC 302)
Inspector:BARRY STRATTON-Comments:Front steps still not corrected.Concrete is
decayed and holes have formed from failure.Gutters still not cleaned out and gutters
extensions still missing on gutters.
FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector: BARRY STRATTON-Comments:Tub surround still not replaced. Bathroom
window has water damage and mold is forming on damaged wood. Bath fan needs
cleaned. Leak in foundation in basement needs reparied. Handrail is needed to
basement.
FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector: BARRY STRATTON-Comments:Mold
FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room
temperature of 68F?(IPMC 602.2)
Inspector:BARRY STRATTON-Comments:Leak under furnace. Possible condensate
line plugged
FAIL
R6.C.-Mechanical Egiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Pnrted On Page 2 of 3
STATUS CODE DESCRIPTION
Inspector: BARRY STRATTON -Comments:Draft hood on water heater needs secured.
GENERAL NOTES
BARRY STRATTON-12/21/2022 @ 12:46 9-7-4 9-7-5:Rental registration was received for 2023. Need registration for 2022.
REINSPECTION DATE
01/17/2023
CONTACT SIGNATURE
Scott Kipp l L
Signed on:12/21/2022 @ 12:47
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on: 12/21/2022 @ 12:47