Loading...
HomeMy WebLinkAbout1257 RAVENWOOD RD INVOICE DATE DUE DATE INVOICE# TOTAL DUE /411 0, 114r4 02/08/2023 03/15/2023 2023-00020337 $50.00 iPgitift °terTo ‘o Customer#: 23270 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 30 SOMETHING REAL ESTATE LLC 715 Mulberry St PO BOX 56 WATERLOO, IA 50703 Waterloo, IA 50704 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 1257 RAVENWOOD RD-2-3-23 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price REINSPECTION FEE 1ST $50.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23270 02/08/2023 03/15/2023 2023-00020337 $50.00 Less Prepayment $0.00 Total Due -* $50.00 City of Waterloo WATERLOO FIRE R ' U INSPECTION REPORT O 30 SOMETHING REAL ESTATE LLc, 1257 RAVENWOOD RD, WATERLOO IA 50702 DETAILS Inspection Date:02/03/2023 I Inspection Type:Complaint j Inspection Number:9430 [ Shift: N/A Station: N/A I Unit: N/A Lead Inspector: BARRY STRATTON Other Inspectors: N/A I Fee:$50.00 f.t /L/"..` �J6 STATUS CODE DESCRIPTION FAIL 704.3-Opening protectives. Where openings are required to be protected, opening protectives shall be maintained self-closing or automatic-closing by smoke detection. Existing fusible-link- type automatic door-closing devices are permitted if the fusible link rating does not exceed 135'F(57'C). Inspector: BARRY STRATTON-Comments:Fire doors held in the open position.Door shall remain in the closed position. FAIL 9-Complaint Field Upon visual inspection does situation match the complaints concerns?Fail to Verification indicate that the complaint was found to be valid and use the codes tab to document what violations were noted.If no violations are noted, pass and use the notes section to indicate that no evidence of the complaints concerns were found. Inspector: BARRY STRATTON-Comments:No hot water. Need to replace water heater un unit#8 FAIL 901.6- Inspection,testing and Fire detection and alarm systems,emergency alarm systems,gas detection systems, maintenance. fire-extinguishing systems, mechanical smoke exhaust systems and smoke and heat vents protection and life safety systems shall be maintained in an operative condition at all times,and shall be replaced or repaired where defective. Nonrequired fire protection and life safety systems and equipment shall be inspected,tested and maintained or removed in accordance with Section 901.8 Inspector: BARRY STRATTON-Comments:Onsite alarm will need resting and maintenance. P•-teo an 02,03 20:3_13.0-1 Page 1 of 3 � 1 STATUS CODE DESCRIPTION FAIL 906.1 -Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.1n new and existing Group A,B, E, F,H, I, M,R-1,R-2, R-4 and S occupancies. Exceptions: 1.1n Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.In Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C.3. In storage areas of Group S occupancies where forklift,powered industrial truck or powered cart operators are the primary occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in accordance with all of the following:3.1. Use of vehicle-mounted extinguishers shall be approved by the fire code official.3.2. Each vehicle shall be equipped with a 10- pound,40A:808:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3, Not less than two spare extinguishers of equal or greater rating shall be available on-site to replace a discharged extinguisher.3.4.Vehicle operators shall be trained in the proper operation,use and inspection of extinguishers.3.5.Inspections of vehicle- mounted extinguishers shall be performed daily.2.Within 30 feet(9144 mill)distance of travel from commercial cooking equipment and from domestic cooking equipment in Group 1-1; 1-2,Condition 1;and R-2 college dormitory occupancies.3.ln areas where flammable or combustible liquids are stored, used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies, in accordance with Section 3316.1.5.Where required by the sections indicated in Table 906.1.6.Special- hazard areas, including but not limited to laboratories,computer rooms and generator rooms,where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Inspector: BARRY STRATTON-Comments:Fire extinguisher missing on main level laundry room. Update extinguishers in building. FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.7 and NFPA 72. alarms. Inspector: BARRY STRATTON-Comments:Detectors missing in unit#8 REINSPECTION DATE 03/03/2023 CONTACT SIGNATURE 30 Something Real Estate LLC Signed on:02/03/2023 @ 13:04 1,ted on 02;03,20:3_' :04 Page 2of3 INSPECTOR SIGNATURE BARRY STRATTON Signed on:02/03/2023 @ 13:04 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Printed on 02/03,2023(1:13:04 Page 3 of 3