Loading...
HomeMy WebLinkAbout422 DANE ST #101 INVOICE DATE DUE DATE INVOICE# TOTAL DUE ih i ` � 02/08/2023 03/15/2023 2023-00020322 � $250.00 °Iterloo �o Customer#: 22009 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable WATERLOO AFFORDABLE HOUSING 715 Mulberry St 740 S 75TH ST WATERLOO, IA 50703 OMAHA,NE 68114 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 422 DANE ST#101 - 1-5-23 FOR BILLING INQUIRY: (319)291-4323 4TH FAILED RE-INSPECTION LDescription Total Price] REINSPECTION FEE 3RD $250.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 22009 02/08/2023 03/15/2023 2023-00020322 $250.00 Less Prepayment $0.00 Total Due $250.00 City of Waterloo \C°\ • WATERLOO FIRE RESCUE INSPECTION REPORT HERITAGE HOUSING LLC, 422 DANE ST, WATERLOO IA 50703 DETAILSog Inspection Date:01/05/2023 I Inspection Type: Rental Inspection inspection Number:9006 f Shift: N/A I Station: N/A Unit: N/A Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$250.00 ' STATUS CODE DESCRIPTION FAIL 1010.1.9-Door operations Except as specifically permitted by this section,egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON-Comments:Screen door will not secure. Door hardware still not hooking up to lock plate. FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:BARRY STRATTON-Comments:Multi adapters FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A,B, E,F, H,I, M,R-1, R-2, R-4 and S occupancies.Exception:In Group R-2 occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3. In areas where flammable or combustible liquids are stored, used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Inspector: BARRY STRATTON-Comments: FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NEPA 72. alarms inspector:BARRY STRATTON-Comments: Pnnted on 0!/O5,2O23 L 09:59 • Page 1 of 2 STATUS CODE DESCRIPTION FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector:BARRY STRATTON-Comments: FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector: BARRY STRATTON-Comments:Cockroaches need exterminated. Drawer front still missing on kitchen counter under sink. REINSPECTION DATE 02/06/2023 CONTACT SIGNATURE John Foley Signed on:01/05/2023 @ 09:58 INSPECTOR SIGNATURE BARRY STRATTON Signed on:01/05/2023 @ 09:58 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Printed on 01/05/2023?c 09:59 Page 2 of 2