RENTAL INSPECTION - 320 DENVER ST- 1-9-23 FOR BILLING INQUIRY: (319)291-4323
LDescription J Total Price J
REINSPECTION FEE 1ST $50.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
10235 02/08/2023 03/15/2023 2023-00020324 $50.00
Less Prepayment $0.00
Total Due $50.00
City of Waterloo
V
WATERLOO FIRE RESCUE 4,It 1Loo
INSPECTION REPORT
DORIS RUFFRIDGE SINGLE FAMILY RENTAL,320 DENVER ST, WATERLOO IA 50701 424410
DETAILS
Inspection Date:01/09/2023 1 Inspection Type: Rental Inspection I Inspection Number: 8934 I Shift: N/A ( Station: N/A
Unit: N/A I Lead Inspector:BARRY STRATTON I Other Inspectors: N/A Fee:$50.00
�f(r/ /h
STATUS CODE DESCRIPTION
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector:BARRY STRATTON-Comments:outlets in open walls on 1st floor.New
electric panel installed without permits/inspections.Service grounding cable not
secured to water meter.Door on panel not secured to box and panel is not marked.
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1.In new
and existing Group A,B,E, F, H, I, M,R-1,R-2,R-4 and S occupancies. Exception: In
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A:10-B:C.2.Within 30 feet(9144 mm)
of commercial cooking equipment.3. In areas where flammable or combustible
liquids are stored,used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies,in accordance with Section 3315.1. 5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas,
including but not limited to laboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector:BARRY STRATTON-Comments:
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector:BARRY STRATTON-Comments:Need detectors installed to meet code
requirements.
FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector:BARRY STRATTON-Comments:CO needed upstairs outside bedrooms.
Printed on 01,09/2023 t:12:58
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may
include boilers,heating equipment,elevator,moving stairways,electrical wiring,and
flammable liquid containers.(IPMC 108.1.2)
Inspector:BARRY STRATTON-Comments:Electric service
FAIL R3-Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPMC
Occupancy 108.1.3)
Inspector:BARRY STRATTON-Comments:None
FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector: BARRY STRATTON-Comments:No smoke detectors installed on 1st floor.
Handrails need installed going upstairs to meet code requirements.
FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
inspector: BARRY STRATTON-Comments:Floors,walls,plumbing,electric,fire safety.
FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector:BARRY STRATTON-Comments:Plumbing
FAIL R6.D.- Receptacles Every habitable space in a dwelling shall contain not less than two separate and
remote receptacle outlets. Every laundry area shall contain not less than one
grounding-type receptacle or a receptacle with a GFCI. Every bathroom shall contain
not less than one receptacle.Any new bathroom receptacle shall have GFCI
protection.All receptacles shall have the appropriate faceplate cover.(IPMC 605.2)
Inspector: BA.RRY STRATTON-Comments:None
RUINSPECTION DATE
02/07/2023
Printed an 01/09/2023 L^a 12:5rB
Page 2 of 3
CONTACT SIGNATURE
Doris Ruffridge (
Signed on:01/09/2023 @ 12:57
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:01/09/2023 @ 12:57