Loading...
HomeMy WebLinkAbout320 DENVER ST INVOICE DATE DUE DATE INVOICE# TOTAL DUE /1i�,1�■� �;,; 02/08/2023 03/15/2023 2023-0002032,1 $50.00 WI Customer#: 10235 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable DORIS RUFFRIDGE 715 Mulberry St 204 E 7TH ST WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 320 DENVER ST- 1-9-23 FOR BILLING INQUIRY: (319)291-4323 LDescription J Total Price J REINSPECTION FEE 1ST $50.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 10235 02/08/2023 03/15/2023 2023-00020324 $50.00 Less Prepayment $0.00 Total Due $50.00 City of Waterloo V WATERLOO FIRE RESCUE 4,It 1Loo INSPECTION REPORT DORIS RUFFRIDGE SINGLE FAMILY RENTAL,320 DENVER ST, WATERLOO IA 50701 424410 DETAILS Inspection Date:01/09/2023 1 Inspection Type: Rental Inspection I Inspection Number: 8934 I Shift: N/A ( Station: N/A Unit: N/A I Lead Inspector:BARRY STRATTON I Other Inspectors: N/A Fee:$50.00 �f(r/ /h STATUS CODE DESCRIPTION FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:BARRY STRATTON-Comments:outlets in open walls on 1st floor.New electric panel installed without permits/inspections.Service grounding cable not secured to water meter.Door on panel not secured to box and panel is not marked. FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A,B,E, F, H, I, M,R-1,R-2,R-4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3. In areas where flammable or combustible liquids are stored,used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies,in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories,computer rooms and generator rooms, where required by the fire code official. Inspector:BARRY STRATTON-Comments: FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector:BARRY STRATTON-Comments:Need detectors installed to meet code requirements. FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector:BARRY STRATTON-Comments:CO needed upstairs outside bedrooms. Printed on 01,09/2023 t:12:58 Page 1 of 3 STATUS CODE DESCRIPTION FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may include boilers,heating equipment,elevator,moving stairways,electrical wiring,and flammable liquid containers.(IPMC 108.1.2) Inspector:BARRY STRATTON-Comments:Electric service FAIL R3-Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPMC Occupancy 108.1.3) Inspector:BARRY STRATTON-Comments:None FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector: BARRY STRATTON-Comments:No smoke detectors installed on 1st floor. Handrails need installed going upstairs to meet code requirements. FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions inspector: BARRY STRATTON-Comments:Floors,walls,plumbing,electric,fire safety. FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition?(IPMC 603.1) Inspector:BARRY STRATTON-Comments:Plumbing FAIL R6.D.- Receptacles Every habitable space in a dwelling shall contain not less than two separate and remote receptacle outlets. Every laundry area shall contain not less than one grounding-type receptacle or a receptacle with a GFCI. Every bathroom shall contain not less than one receptacle.Any new bathroom receptacle shall have GFCI protection.All receptacles shall have the appropriate faceplate cover.(IPMC 605.2) Inspector: BA.RRY STRATTON-Comments:None RUINSPECTION DATE 02/07/2023 Printed an 01/09/2023 L^a 12:5rB Page 2 of 3 CONTACT SIGNATURE Doris Ruffridge ( Signed on:01/09/2023 @ 12:57 INSPECTOR SIGNATURE BARRY STRATTON Signed on:01/09/2023 @ 12:57 QUESTIONS AIOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 PtearOO .2O23fc5 Page 3 of 3