Loading...
HomeMy WebLinkAbout1125-1133 DIXON DR (2) INVOICE DATE DUE DATE INVOICE# TOTAL DUE °��irk 05/05/2023 06/10/2023 2023-00020438 $50.00 •plse°l'erloo o Customer#: 24076 Please Make Check Payable and Remit To: City of Waterloo A TTN: City Clerk/Accounts Receivable HUNDRED TICKET VISION LLC 715 Mulberry St PO BOX 56 WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION- 1125=1133 DIXON DR-4-26-23 FOR BILLING INQUIRY: (319)291-4323 LDescription Total Price REINSPECTION FEE 1ST $50.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24076 05/05/2023 06/10/2023 2023-00020438 $50.00 Less Prepayment $0.00 Total Due $50.00 City of Waterloo . ^ WATERLOO ������� �� ,���`u / \u�- ` ����� ������n� ��]�� J���������� �` INSPECTION REPORT 11���������������������� ������� ������� ���� � ��' CIA DETAILS Inspection Date:04/26/2023 | Inspection Type: Rental Inspection | Inspection Number: 9936 | Shift: N/A Station: N/A � Unit: N/A | Lead Inspector: BARRvSTRATTON I Other Inspectors: N/A | Fee:$50.08 SrwTmS CODE DfSKRmPn)ON / FAIL 1008.1 Means of egress Illumination shall be provided in the means of egress in accordance with Section illumination. 1008.2. Under emergency power, means of egress illumination shall comply with Section 1008.3. Inspector: BARRYSTRATTON Comments:Egress lighting does not work.Today's inspections lights sci|l do not work. Location: Not Provided FAIL 1032,2 Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is Occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means ofegress, Inspector: BARRYSTRAlTON Comments:Front door threshold(s obstructing door from closing.Threshold is still not repaired. Location: Not Provided FAIL 603.2 Abatement of unsafe identified electrical hazards shall be abated. Identified hazardous electrical conditions conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official. hazards. Electrical wiring, devices'appliances and other equipmenc that ismodified o, damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not beused. Inspector: 8ARRYSTRATTOw Comments:A[disconnect box on East side ofbuilding is hanging by wires. Box needs secured to building.AC disconnect box still hanging from building. Location: Not Provided � mm+ Page 1or4 STATUS CODE DESCRIPTION FAIL 704.3-Opening protectives. Where openings are required to be protected,opening protectives shall be maintained self-closing or automatic-closing by smoke detection. Existing fusible-link- type automatic door-closing devices are permitted if the fusible link rating does not exceed 135°F(57°C). Inspector: BARRY STRATTON-Comments: Fire doors in open position. Fire doors still left in the open position on todays inspection, may require door closures installed on doors. Location: Not Provided FAIL 901.6- Inspection,testing and Fire detection and alarm systems,emergency alarm systems,gas detection systems, maintenance. fire-extinguishing systems,mechanical smoke exhaust systems and smoke and heat vents protection and life safety systems shall be maintained in an operative condition at all times,and shall be replaced or repaired where defective. Nonrequired fire protection and life safety systems and equipment shall be inspected,tested and maintained or removed in accordance with Section 901.8. Inspector: BARRY STRATTON-Comments:Alarm need maintenance and testing. Alarm testing still requires tested. Location: Not Provided Printed on 04125r2023 c 04:14 Page 2 of 4 ^ S TA TUS CODE DESCRIPTION FAIL e06.1 Where required, Pot-table fire extinguishers shall be installed in all of the following locations: 1.1n new and existing Group A, B. E' F, H' |' M' R,1' R'2, R~4 and S occupancies. Exceptions: 1.m Group R'2 oocupancies, portable fire extinguishers shall be required only in locations specified in items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minirnum rating of 1-A:10-B:C.2.In Group E Occupancies, portable fire extinguishers shall be required only in locations specified in items 2 through 6 where each classroom is provided with a portable fire extinguisher having a rninirrium rating of 2-A:20-B:C.3. In storage areas of Group S occupancies where forklift, powered industrial truck or powered cart operators are the primary occupants,fixed extinguishers,as specified in NFPA 10, shall not be required where in accordance with all of the following:3.1. Use of vehicle-11101-inted extinguishers shall be approved by the fire code official.3.2.Each vehicle shall be equipped with a 10' pound.40A:8UB:[extinguisheraffixedtothevehideusingamountingbracker approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not less than two spare extinguishers of equal or greater rating shall be available on-site to replace a discharged extinguisher.34.Vehide operators shall be trained in the proper operation, use and inspection of extinguishers. lS.Inspections n[vehicle- mounted extinguisherssha|{ beperformeddai|y.2.vvithin30feet(g144mnn)distance of travel from commercial cooking equipment and from domestic cooking equipwient in Group 1-1; 1-2,Condition 1;and R-2 college dormitory occupancies.3.In areas where flammable or combustible liquids are stored, used or dispensed.4.On each floor of suuctures under construction, except Group R'3 occupancies. in accordance with Section 3316.1. 5.VVhere required by the sections indicated in Table yO6.1.0.Specia|' hazardareas' indudingbutnot|imitedto|abonatories'computerroomsand generator rooms,where required by the fire code official. Exception: Pot-table fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Inspector: BARRvSTRATTUN Comments:Fire Extinguishers need updared. (2o21) Fire extinguishers still out of date(2021). Location: Not Provided 6AIIL R4 Exterior Property Areas Is the exterior property area maintained in a dean' safe,and sanitary condition?This includes grading and drainage,sidewalks and driveways,weeds, and pest infestations.(|PM[3O2} Inspector: 8ARRYSTR/QTON Comments:Front concrete slab at door. Busted concrete missing that is under slab.Concrete slab still broken and needs repaired. Location: Not Provided FAIL R6 Interior Structure Has the interior of the structure and equipment inside been maintained ill good repair,structurally sound,and in a sanitary condition?(|PK4[305) Inspector:BARRYSTRATT0N Comments: Egress lights,fire extinguishers,fire doors, front door threshold. Location: Not Provided 6ENERuLmYOTES ,,'"te""" Page oor4 ° . BARRYSTRA7TON 04/26/2023 @ 0912 RP complaining of terrible smell in unit#1.Upon investigation nobody was at unit# 1 so entry was not made.Smell in building was consistent with cooking/frying. xsovsprcnmNoAne 85/24/2023 CONTACT SIGNATURE Caliber Group /— �� / )| Signed on:O4/26/ZO236�U9:r3 �� | /� /�— INSPECTOR SIGNATURE OARRYSTRATrON Signed on:84/26/2023 @ 09:14 ~ QUESTIONS ABOUT YOUR INSPECTION? 8ARRvSTRATTON oarry.strauon@watedoo'ia or,g (319)231'9147 wm"oon 04/2ez07': �� ^ Page 4or4