RENTAL INSPECTION- 1125=1133 DIXON DR-4-26-23 FOR BILLING INQUIRY: (319)291-4323
LDescription Total Price
REINSPECTION FEE 1ST $50.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
24076 05/05/2023 06/10/2023 2023-00020438 $50.00
Less Prepayment $0.00
Total Due $50.00
City of Waterloo
. ^
WATERLOO ������� �� ,���`u / \u�- `
����� ������n� ��]�� J���������� �`
INSPECTION REPORT
11���������������������� ������� ������� ���� � ��'
CIA
DETAILS
Inspection Date:04/26/2023 | Inspection Type: Rental Inspection | Inspection Number: 9936 | Shift: N/A Station: N/A �
Unit: N/A | Lead Inspector: BARRvSTRATTON I Other Inspectors: N/A | Fee:$50.08
SrwTmS CODE DfSKRmPn)ON /
FAIL 1008.1 Means of egress Illumination shall be provided in the means of egress in accordance with Section
illumination. 1008.2. Under emergency power, means of egress illumination shall comply with
Section 1008.3.
Inspector: BARRYSTRATTON Comments:Egress lighting does not work.Today's
inspections lights sci|l do not work.
Location: Not Provided
FAIL 1032,2 Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is Occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
means ofegress,
Inspector: BARRYSTRAlTON Comments:Front door threshold(s obstructing door
from closing.Threshold is still not repaired.
Location: Not Provided
FAIL 603.2 Abatement of unsafe identified electrical hazards shall be abated. Identified hazardous electrical conditions
conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official.
hazards. Electrical wiring, devices'appliances and other equipmenc that ismodified o,
damaged and constitutes Conditions that constitute an electrical shock or fire hazard
shall be abated not beused.
Inspector: 8ARRYSTRATTOw Comments:A[disconnect box on East side ofbuilding
is hanging by wires. Box needs secured to building.AC disconnect box still hanging
from building.
Location: Not Provided
�
mm+
Page 1or4
STATUS CODE DESCRIPTION
FAIL 704.3-Opening protectives. Where openings are required to be protected,opening protectives shall be
maintained self-closing or automatic-closing by smoke detection. Existing fusible-link-
type automatic door-closing devices are permitted if the fusible link rating does not
exceed 135°F(57°C).
Inspector: BARRY STRATTON-Comments: Fire doors in open position. Fire doors still
left in the open position on todays inspection, may require door closures installed on
doors.
Location: Not Provided
FAIL 901.6- Inspection,testing and Fire detection and alarm systems,emergency alarm systems,gas detection systems,
maintenance. fire-extinguishing systems,mechanical smoke exhaust systems and smoke and heat
vents protection and life safety systems shall be maintained in an operative condition
at all times,and shall be replaced or repaired where defective. Nonrequired fire
protection and life safety systems and equipment shall be inspected,tested and
maintained or removed in accordance with Section 901.8.
Inspector: BARRY STRATTON-Comments:Alarm need maintenance and testing.
Alarm testing still requires tested.
Location: Not Provided
Printed on 04125r2023 c 04:14
Page 2 of 4
^
S TA TUS CODE
DESCRIPTION
FAIL e06.1 Where required, Pot-table fire extinguishers shall be installed in all of the following locations: 1.1n new
and existing Group A, B. E' F, H' |' M' R,1' R'2, R~4 and S occupancies. Exceptions: 1.m
Group R'2 oocupancies, portable fire extinguishers shall be required only in locations
specified in items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minirnum rating of 1-A:10-B:C.2.In Group E Occupancies,
portable fire extinguishers shall be required only in locations specified in items 2
through 6 where each classroom is provided with a portable fire extinguisher having
a rninirrium rating of 2-A:20-B:C.3. In storage areas of Group S occupancies where
forklift, powered industrial truck or powered cart operators are the primary
occupants,fixed extinguishers,as specified in NFPA 10, shall not be required where in
accordance with all of the following:3.1. Use of vehicle-11101-inted extinguishers shall
be approved by the fire code official.3.2.Each vehicle shall be equipped with a 10'
pound.40A:8UB:[extinguisheraffixedtothevehideusingamountingbracker
approved by the extinguisher manufacturer or the fire code official for vehicular use.
3.3. Not less than two spare extinguishers of equal or greater rating shall be available
on-site to replace a discharged extinguisher.34.Vehide operators shall be trained in
the proper operation, use and inspection of extinguishers. lS.Inspections n[vehicle-
mounted extinguisherssha|{ beperformeddai|y.2.vvithin30feet(g144mnn)distance
of travel from commercial cooking equipment and from domestic cooking equipwient
in Group 1-1; 1-2,Condition 1;and R-2 college dormitory occupancies.3.In areas where
flammable or combustible liquids are stored, used or dispensed.4.On each floor of
suuctures under construction, except Group R'3 occupancies. in accordance with
Section 3316.1. 5.VVhere required by the sections indicated in Table yO6.1.0.Specia|'
hazardareas' indudingbutnot|imitedto|abonatories'computerroomsand
generator rooms,where required by the fire code official. Exception: Pot-table fire
extinguishers are not required at normally unmanned Group U occupancy buildings
or structures where a portable fire extinguisher suitable to the hazard of the location
is provided on the vehicle of visiting personnel.
Inspector: BARRvSTRATTUN Comments:Fire Extinguishers need updared. (2o21)
Fire extinguishers still out of date(2021).
Location: Not Provided
6AIIL R4 Exterior Property Areas Is the exterior property area maintained in a dean' safe,and sanitary condition?This
includes grading and drainage,sidewalks and driveways,weeds, and pest
infestations.(|PM[3O2}
Inspector: 8ARRYSTR/QTON Comments:Front concrete slab at door. Busted
concrete missing that is under slab.Concrete slab still broken and needs repaired.
Location: Not Provided
FAIL R6 Interior Structure Has the interior of the structure and equipment inside been maintained ill good
repair,structurally sound,and in a sanitary condition?(|PK4[305)
Inspector:BARRYSTRATT0N Comments: Egress lights,fire extinguishers,fire doors,
front door threshold.
Location: Not Provided
6ENERuLmYOTES
,,'"te"""
Page oor4
° .
BARRYSTRA7TON 04/26/2023 @ 0912 RP complaining of terrible smell in unit#1.Upon investigation nobody was at unit# 1
so entry was not made.Smell in building was consistent with cooking/frying.