RENTAL INSPECTION- 200-255 PARK VIEW BLVD - 12-15-22 FOR BILLING INQUIRY: (319)291-4323
LDescription I Total Price J
REINSPECTION FEE 1ST $50.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
24063 05/05/2023 06/10/2023 2023-00020426 $50.00
Less Prepayment $0.00
Total Due-4 $50.00
City of Waterloo
WATERLOO FIRE RESCUE
(../3 to, .44„„,„„
.
INSPECTION REPORT
PARK VIEW APARTMENTS, 200-255 PARK VIEW BLVD, WATERLOO/A 50702 U1 ' RE`
DETAILS OC /1
Inspection Date: 12/15/2022 ( Inspection Type: Rental Inspection I Inspection Number:9171 Shift: N/A j Station: N/A
Unit: N/A j Lead Inspector: BARRY STRATTON Other Inspectors: N/A j Fee:$50.00
/'9-1 d"q4 74st
STATUS CODE DESCRIPTION
FAIL 1010.1.9-Door operations Except as specifically permitted by this section, egress doors shall be readily
openable from the egress side without the use of a key or special knowledge or
effort.
Inspector: BARRY STRATTON- Comments: Rear entrance door to building containing
#252 need to be replaced.Jamb is broken and door is broken.
FAIL 315.1 -General Storage shall be in accordance with Sections 315.2 through 315.5.
Inspector:BARRY STRATTON-Comments:Storage in mechanical to close to water
heater and furnace. Storage in electrical closet in common hallway all debris needs
removed.
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices, appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRY STRATTON-Comments:Mechanical room has romex wired from
electric boxes.Wires need to be in EMT. Light in bathroom not working and light in
kitchen in 252 not working. Hallway mechanical closet needs wiring addressed and
need holes in electric boxes covered. Need licensed electrician to correct deficiencies
with electrical issues.
FRIL 605.5-Extension cords Extension cords and flexible cords shall not be a substitute for permanent wiring.
Extension cords and flexible cords'shall not be affixed to structures,extended
through walls,ceilings or floors,or under doors or floor coverings, nor shall such
cords be subject to environmental damage or physical impact. Extension cords shall
be used only with portable appliances.
Inspector: BARRY STRATTON-Comments: Extension cord to micro wave needs
removed.Appliances need direct connection to outlets. Remove all extension cords.
Page 1 of 3
{ _r,
STATUS CODE DESCR/l T/ON
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector:BARRY STRATTON-Comments: Need smoke detector in hallway outside
bedrooms.
FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector: BARRY STRATTON-Comments:Need CO detector outside of the
bedrooms.
FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair, structurally sound,and in a sanitary condition?(IPMC 305)
Inspector:BARRY STRATTON-Comments:Water damage in bathroom. Peeling paint
and holes in walls.Abraded paint from water damage. Remove all damaged drywall
and replace. Door hardware needs replaced on mechanical room door. No
corrections have been done to unit 252.
R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector: BARRY STRATTON-Comments:Stove/oven does not wok.Stove has no:
been replaced.
GENERAL NOTES
BARRY STRATTON-12/15/2022 @ 11:39 Unit#252 Park View BD
REINSPECTION DATE
01/12/2023
CONTACT SIGNATURE
Matt Matthias L 1Vt n��1�
Signed on: 12/15/2022 @ 11:39 1
Page2of3
M ' �
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on: 12/15/2022 @ 11:39
QUESTIONS ABOUT YOUR INSPECTION?
BARRY STRATTON
bany.stratton@waterloo-ia.org
(319)231-9147
Printed On 12115/2022 tc