INSPECTION REPORT¢.
523 REED ST LITCHFIELD ADDITION LOT 18 BLK 4,523 REED ST, WATERLOO IA 50703 (�
QN
DETAILS
'09
'91t ,S
Inspection Date:04/20/2023 ; Inspection Type: Rental Inspection I Inspection Number:9898 I Shift: N/A I Station: N/ I
Unit: N/A I Lead Inspector: BARRY STRATTON I Other Inspectors: N/A ; Fee:$100.00 �4 /j /s
STATUS CODE DESCRIPTION
FAIL 1031.1 -General. Emergency escape and rescue openings shall comply with the requirements of this
section.
Inspector: BARRY STRATTON-Comments: Replace/repair all broken windows.
FAIL 603.2-Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions
conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official.
hazards. Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes Conditions that constitute an electrical shock or fire hazard
shall be abated not be used.
Inspector: BARRY STRATTON-Comments:Missing outlet covers, need 3'clearance to
electric panel,Open box with exposed wires in stairway to upstairs, Light fixtures
hanging from ceiling,and all lights need globes.SEU Cable on exterior of house needs
replaced.SEU Cable is not strapped to meet code requirements.
Printer on 04/20/2023 _--
Page 1 of 5
{ • •
STATUS CODE DESCRIPTION
FAIL 906.1 -Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.In new
and existing Group A, B, E, F, H, I, M, R-1,R-2, R-4 and S occupancies. Exceptions: 1.In
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A:10-B:C.2.In Group E occupancies,
portable fire extinguishers shall be required only in locations specified in Items 2
through 6 where each classroom is provided with a portable fire extinguisher having
a minimum rating of 2-A:20-B:C.3. In storage areas of Group S occupancies where
forklift,powered industrial truck or powered cart operators are the primary
occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in
accordance with all of the following:3.1.Use of vehicle-mounted extinguishers shall
be approved by the fire code official.3.2. Each vehicle shall be equipped with a 10-
pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket
approved by the extinguisher manufacturer or the fire code official for vehicular use.
3.3. Not less than two spare extinguishers of equal or greater rating shall be available
on-site to replace a discharged extinguisher.3.4.Vehicle operators shall be trained in
the proper operation,use and inspection of extinguishers.3.5. Inspections of vehicle-
mounted extinguishers shall be performed daily.2.Within 30 feet(9144 mm)distance
of travel from commercial cooking equipment and from domestic cooking equipment
in Group 1-1; 1-2,Condition 1;and R-2 college dormitory occupancies.3.In areas where
flammable or combustible liquids are stored, used or dispensed.4.On each floor of
structures under construction, except Group R-3 occupancies, in accordance with
Section 3316.1.5.Where required by the sections indicated in Table 906.1.6.Special-
hazard areas, including but not limited to laboratories,computer rooms and
generator rooms,where required by the fire code official. Exception: Portable fire
extinguishers are not required at normally unmanned Group U occupancy buildings
or structures where a portable fire extinguisher suitable to the hazard of the location
is provided on the vehicle of visiting personnel.
Inspector: BARRY STRATTON-Comments:Need Fire Extinguisher in unit.
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall he
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.7 and NFPA 72.
alarms.
Inspector: BARRY STRATTON-Comments:Need detectors in each bedroom, outside
bedrooms,and in basement
FAIL 915.1 -General. Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector:BARRY STRATTON-Comments:Need CO detectors installed in vicinity of
any bedroom.
FAIL R3-Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPMC
Occupancy 108.1.3)
Inspector: BARRY STRATTON-Comments:House in current condition is not habitable.
Printed on 04/20/2023 CO.10:42
Page 2 of 5
•
STATUS CODE DESCRIPTION
FAIL R4- Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This
includes grading and drainage,sidewalks and driveways,weeds,and pest
infestations.(IPMC 302)
Inspector:BARRY STRATTON-Comments:Debris all around rear of property.
FAIL R5- Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and
sanitary state?(IPMC 304)
Inspector: BARRY STRATTON -Comments: Foundation, Roof and gutters
FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector: BARRY STRATTON-Comments:Peeling paint,holes in walls flooring in living
room and kitchen needs replaced,living room ceiling collapse,Walls in bathroom,
register vent covers, kitchen counters and cabinets need replaced, basement stairs
need replaced,upstairs floors warped, missing handrails to basement and upstairs,
tub surround needs replaced, Foundation needs repaired, mice and cockroaches
need exterminated.
FAIL R6.D.- Receptacles Every habitable space in a dwelling shall contain not less than two separate and
remote receptacle outlets. Every laundry area shall contain not less than one
grounding-type receptacle or a receptacle with a GFCI. Every bathroom shall contain
not less than one receptacle.Any new bathroom receptacle shall have GFCI
protection.All receptacles shall have the appropriate faceplate cover.(IPMC 605.2)
Inspector: BARRY STRATTON-Comments: Need approved outlets covers on switches
and outlets.
GENERAL NOTES
BARRY STRATTON-04/20/2023 @ 10:40 9-7-4 9-7-5: Need all rental units registered with the City of Waterloo Still not registered
2023
BARRY STRATTON-04/20/2023 @ 10:40 504.1 General.Plumbing fixtures shall be properly installed and maintained in working
order,and shall be kept free from obstructions, leaks and defects and be capable of
performing the function for which such plumbing fixtures are designed.Plumbing
fixtures shall be maintained in a safe,sanitary and functional condition. Kitchen sink
does not work.Tub surround needs replaced.
BARRY STRATTON-04/20/2023 10:40 505.3 Supply.The water supply system shall be installed and maintained to provide a
supply of water to plumbing fixtures,devices and appurtenances in sufficient volume
and at pressures adequate to enable the fixtures to function properly,safely,and free
from defects and leaks.
Printed on 04f20i2023 c.10:42
Page 3 of 5
GENERAL NOTES
BARRY STRATTON-04/20/2023 @ 10:40 605.1 Installation. Electrical equipment,wiring and appliances shall be properly
installed and maintained in a safe and approved manner.605.2 Receptacles. Every
habitable space in a dwelling shall contain not less than two separate and remote
receptacle outlets. Every laundry area shall contain not less than one grounding-type
receptacle or a receptacle with a ground fault circuit interrupter. Every bathroom shall
contain not less than one receptacle.Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection.All receptacle outlets shall have the
appropriate faceplate cover for the location.
BARRY STRATTON-04/20/2023 @ 10:40 305.1 General.The interior of a structure and equipment therein shall be maintained in
good repair, structurally sound and in a sanitary condition.Occupants shall keep that
part of the structure that they occupy or control in a clean and sanitary condition.
Every owner of a structure containing a rooming house, housekeeping units,a hotel,a
dormitory,two or more dwelling units or two or more nonresidential occupancies,
shall maintain, in a clean and sanitary condition,the shared or public areas of the
structure and exterior property.
BARRY STRATTON-04/20/2023 @ 10:40 conditions shall be corrected.305.4 Stairs and walking surfaces. Every stair, ramp,
landing, balcony,porch,deck or other walking surface shall be maintained in sound
condition and good repair.
BARRY STRATTON-04/20/2023 @ 10:42 Corrections not done and unit is now occupied by a different tenant. Failure to bring to
code the City Shall issue citations for rental violations.
REINSPECTION DATE
05/18 2023
CONTACT SIGNATURE
Daejaun O'Neal /\t\NL_Signed on:04/20/2023 @ 10:42
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:04/20/2023 @ 10:42
Printed on 04!2O12O23 rg:10:42
Page 4 of 5