Loading...
HomeMy WebLinkAbout523 REED ST (4) �..� INVOICE DATE DUE DATE INVOICE it TOTAL DUE /IIC \III\ 1�:�Nr;,; 05/05/2023 06/10/2023 2023-00020431 $100.00 °fetloo A° Customer#: 24064 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable DAEJUAN O'NEAL 715 Mulberry St 637 DAWSON WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION- 523 REED ST-4-20-23 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price NO SHOW INSPECTION FEE $100.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24064 05/05/2023 06/10/2023 2023-00020431 $100.00 Less Prepayment $0.00 Total Due—> S100.00 City of Waterloo WATERLOO FIRE RESCUE t/ � `�`` INSPECTION REPORT¢. 523 REED ST LITCHFIELD ADDITION LOT 18 BLK 4,523 REED ST, WATERLOO IA 50703 (� QN DETAILS '09 '91t ,S Inspection Date:04/20/2023 ; Inspection Type: Rental Inspection I Inspection Number:9898 I Shift: N/A I Station: N/ I Unit: N/A I Lead Inspector: BARRY STRATTON I Other Inspectors: N/A ; Fee:$100.00 �4 /j /s STATUS CODE DESCRIPTION FAIL 1031.1 -General. Emergency escape and rescue openings shall comply with the requirements of this section. Inspector: BARRY STRATTON-Comments: Replace/repair all broken windows. FAIL 603.2-Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official. hazards. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Inspector: BARRY STRATTON-Comments:Missing outlet covers, need 3'clearance to electric panel,Open box with exposed wires in stairway to upstairs, Light fixtures hanging from ceiling,and all lights need globes.SEU Cable on exterior of house needs replaced.SEU Cable is not strapped to meet code requirements. Printer on 04/20/2023 _-- Page 1 of 5 { • • STATUS CODE DESCRIPTION FAIL 906.1 -Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A, B, E, F, H, I, M, R-1,R-2, R-4 and S occupancies. Exceptions: 1.In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.In Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C.3. In storage areas of Group S occupancies where forklift,powered industrial truck or powered cart operators are the primary occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in accordance with all of the following:3.1.Use of vehicle-mounted extinguishers shall be approved by the fire code official.3.2. Each vehicle shall be equipped with a 10- pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not less than two spare extinguishers of equal or greater rating shall be available on-site to replace a discharged extinguisher.3.4.Vehicle operators shall be trained in the proper operation,use and inspection of extinguishers.3.5. Inspections of vehicle- mounted extinguishers shall be performed daily.2.Within 30 feet(9144 mm)distance of travel from commercial cooking equipment and from domestic cooking equipment in Group 1-1; 1-2,Condition 1;and R-2 college dormitory occupancies.3.In areas where flammable or combustible liquids are stored, used or dispensed.4.On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3316.1.5.Where required by the sections indicated in Table 906.1.6.Special- hazard areas, including but not limited to laboratories,computer rooms and generator rooms,where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Inspector: BARRY STRATTON-Comments:Need Fire Extinguisher in unit. FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall he multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.7 and NFPA 72. alarms. Inspector: BARRY STRATTON-Comments:Need detectors in each bedroom, outside bedrooms,and in basement FAIL 915.1 -General. Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector:BARRY STRATTON-Comments:Need CO detectors installed in vicinity of any bedroom. FAIL R3-Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPMC Occupancy 108.1.3) Inspector: BARRY STRATTON-Comments:House in current condition is not habitable. Printed on 04/20/2023 CO.10:42 Page 2 of 5 • STATUS CODE DESCRIPTION FAIL R4- Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This includes grading and drainage,sidewalks and driveways,weeds,and pest infestations.(IPMC 302) Inspector:BARRY STRATTON-Comments:Debris all around rear of property. FAIL R5- Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and sanitary state?(IPMC 304) Inspector: BARRY STRATTON -Comments: Foundation, Roof and gutters FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector: BARRY STRATTON-Comments:Peeling paint,holes in walls flooring in living room and kitchen needs replaced,living room ceiling collapse,Walls in bathroom, register vent covers, kitchen counters and cabinets need replaced, basement stairs need replaced,upstairs floors warped, missing handrails to basement and upstairs, tub surround needs replaced, Foundation needs repaired, mice and cockroaches need exterminated. FAIL R6.D.- Receptacles Every habitable space in a dwelling shall contain not less than two separate and remote receptacle outlets. Every laundry area shall contain not less than one grounding-type receptacle or a receptacle with a GFCI. Every bathroom shall contain not less than one receptacle.Any new bathroom receptacle shall have GFCI protection.All receptacles shall have the appropriate faceplate cover.(IPMC 605.2) Inspector: BARRY STRATTON-Comments: Need approved outlets covers on switches and outlets. GENERAL NOTES BARRY STRATTON-04/20/2023 @ 10:40 9-7-4 9-7-5: Need all rental units registered with the City of Waterloo Still not registered 2023 BARRY STRATTON-04/20/2023 @ 10:40 504.1 General.Plumbing fixtures shall be properly installed and maintained in working order,and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed.Plumbing fixtures shall be maintained in a safe,sanitary and functional condition. Kitchen sink does not work.Tub surround needs replaced. BARRY STRATTON-04/20/2023 10:40 505.3 Supply.The water supply system shall be installed and maintained to provide a supply of water to plumbing fixtures,devices and appurtenances in sufficient volume and at pressures adequate to enable the fixtures to function properly,safely,and free from defects and leaks. Printed on 04f20i2023 c.10:42 Page 3 of 5 GENERAL NOTES BARRY STRATTON-04/20/2023 @ 10:40 605.1 Installation. Electrical equipment,wiring and appliances shall be properly installed and maintained in a safe and approved manner.605.2 Receptacles. Every habitable space in a dwelling shall contain not less than two separate and remote receptacle outlets. Every laundry area shall contain not less than one grounding-type receptacle or a receptacle with a ground fault circuit interrupter. Every bathroom shall contain not less than one receptacle.Any new bathroom receptacle outlet shall have ground fault circuit interrupter protection.All receptacle outlets shall have the appropriate faceplate cover for the location. BARRY STRATTON-04/20/2023 @ 10:40 305.1 General.The interior of a structure and equipment therein shall be maintained in good repair, structurally sound and in a sanitary condition.Occupants shall keep that part of the structure that they occupy or control in a clean and sanitary condition. Every owner of a structure containing a rooming house, housekeeping units,a hotel,a dormitory,two or more dwelling units or two or more nonresidential occupancies, shall maintain, in a clean and sanitary condition,the shared or public areas of the structure and exterior property. BARRY STRATTON-04/20/2023 @ 10:40 conditions shall be corrected.305.4 Stairs and walking surfaces. Every stair, ramp, landing, balcony,porch,deck or other walking surface shall be maintained in sound condition and good repair. BARRY STRATTON-04/20/2023 @ 10:42 Corrections not done and unit is now occupied by a different tenant. Failure to bring to code the City Shall issue citations for rental violations. REINSPECTION DATE 05/18 2023 CONTACT SIGNATURE Daejaun O'Neal /\t\NL_Signed on:04/20/2023 @ 10:42 INSPECTOR SIGNATURE BARRY STRATTON Signed on:04/20/2023 @ 10:42 Printed on 04!2O12O23 rg:10:42 Page 4 of 5 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Printed on 04/20/2023 tiT,10:42 Page 5 of 5