RENTAL INSPECTION- 3203 ROCKY RD -4-17-23 FOR BILLING INQUIRY: (319)291-4323
LDescription ( Total Price
NO SHOW INSPECTION FEE $100.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
24065 05/05/2023 06/10/2023 2023-00020433 $100.00
Less Prepayment $0.00
Total Due — $100.00
City of Waterloo
WATERLOO FIRE RESCUE \oci 44,CF L%
INSPECTION REPORTeppA {iv
MAME AIKEY SINGLE FAMILY RENTAL, 320.E ROCKY RD, WATERLOO IA S0707
DETAILS )C
inspection Date:04/17/2023 Inspection Type: Rental Inspection ( Inspection Number: 10050 Shift: N/A 1 Station: N/A
Unit: N/A j Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$100.00
,e0Y-4517eLtdi
STATUS CODE DESCRIPTION
FAIL 906.1 -Where required. Portable fire extinguishers shall be installed in all of the following locations: 1in new
and existing Group A, B,E, F, H,I,M,R-1,R-2,R-4 and S occupancies. Exceptions: 1in
Group R-2 occupancies,portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A:10-B:C.2.In Group E occupancies,
portable fire extinguishers shall be required only in locations specified in Items 2
through 6 where each classroom is provided with a portable fire extinguisher having
a minimum rating of 2-A:20-B:C.3.In storage areas of Group S occupancies where
forklift, powered industrial truck or powered cart operators are the primary
occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in
accordance with all of the following:3.1.Use of vehicle-mounted extinguishers shall
be approved by the fire code official.3.2. Each vehicle shall be equipped with a 10-
pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket
approved by the extinguisher manufacturer or the fire code official for vehicular use.
3.3.Not less than two spare extinguishers of equal or greater rating shall be available
on-site to replace a discharged extinguisher.3.4.Vehicle operators shall be trained in
the proper operation,use and inspection of extinguishers.3.5.Inspections of vehicle-
mounted extinguishers shall be performed daily.2.Within 30 feet(9144 mill)distance
of travel from commercial cooking equipment and from domestic cooking equipment
in Group 1-1; 1-2,Condition 1;and R-2 college dormitory occupancies.3.In areas where
flammable or combustible liquids are stored,used or dispensed.4.On each floor of
structures under construction,except Group R-3 occupancies,in accordance with
Section 3316.1.5.Where required by the sections indicated in Table 906.1.6.Special-
hazard areas,including but not limited to laboratories,computer rooms and
generator rooms,where required by the fire code official.Exception:Portable fire
extinguishers are not required at normally unmanned Group U occupancy buildings
or structures where a portable fire extinguisher suitable to the hazard of the location
is provided on the vehicle of visiting personnel.
Inspector:BARRY STRATTON-Comments:
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.7 and NFPA 72.
alarms.
Inspector: BARRY STRATTON-Comments:
Printed on 04/17/2023 a 08:04
Page lof3
STATUS CODE DESCRIPTION
FAR. 915.1 -General. Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector:BARRY STRATTON-Comments:
FAIL R1 - Unsafe Structures Is the structure found to be dangerous to the life,health,property or safety of either
the public or occupants of the structure?(IPMC 108.1.1)
Inspector:BARRY STRATTON-Comments:
FAIL R3-Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPMC
Occupancy 108.1.3)
Inspector: BARRY STRATTON-Comments:
FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector: BARRY STRATTON-Comments:Plumbing
FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector: BARRY STRATTON-Comments:Sewer back up. Plumbing System not
working.
GENERAL NOTES
BARRY STRATTON-04117/2023 @ 07:58 9-4-4: DEFECTIVE WORK;UNSANITARY CONDITIONS:Whenever it shall come to the
knowledge of the plumbing inspector that the plumbing in a building causes a
nuisance or may cause disease, sickness,or otherwise becomes a hazard to health, it
shall be the duty of said inspector to make an inspection of such plumbing and render
a report to the proper party,setting forth the necessary repairs or alterations required
to make such plumbing conform to this chapter.The inspector shall set a limit of time
in which such repairs or alterations are to be made,and upon the refusal or neglect of
the owner,agent,lessee or tenant to comply with said notice within the time stated,
the plumbing inspector shall cause such repairs or alterations to be made and such
nuisance abated and the expense of such work shall be taxed against such property
and become a prior lien thereon;or the inspector may order the premises vacated and
closed to further occupancy until such time as the required repairs or alterations have
been made.(Ord.5392,3-20-2017;amd.Ord.5673,11-21-2022)
Printed an 04/17/2023 c 08:04
Page 2 of 3
GENERAL NOTES
BARRY STRATTON-04/17/2023 @ 08:00 9-7-4 9-7-5:2023 Rental Registration is needed for listed address. Listed address has
never been registered.
BARRY STRATTON-04/17/2023 @ 08:01 111.1.2 Unsafe equipment.Unsafe equipment includes any boiler, heating equipment,
elevator, moving stairway,electrical wiring or device,flammable liquid containers or
other equipment on the premises or within the structure that is in such disrepair or
condition that such equipment is a hazard to life, health, property or safety of the
public or occupants of the premises or structure.
BARRY STRATTON-04/17/2023 @ 08:01 111.1.3 Structure unfit for human occupancy.A structure is unfit for human occupancy
whenever the code official finds that such structure is unsafe, unlawful or, because of
the degree to which the structure is in disrepair or lacks maintenance, is insanitary,
vermin or rat infested,contains filth and contamination,or lacks ventilation,
illumination,sanitary or heating facilities or other essential equipment required by this
code, or because the location of the structure constitutes a hazard to the occupants of
the structure or to the public.
REINSPECTION DATE
05/15/2023
CONTACT SIGNATURE
Jamie Aikey
Signed on:04/17/2023 @ 08:03 n\\
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:04/17/2023 @ 08:03