Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1133 DIXON DR
W Aq?. INVOICE DATE DUE DATE INVOICE# TOTAL DUE A t, 11/16/2023 12/20/2023 2024-00000107 $250.00 ti . . a 0 43. Customer#: 24076 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable HUNDRED TICKET VISION LLC 715 Mulberry St PO BOX 56 WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 1133 DIXON DR- 11-16-23 FOR BILLING INQUIRY: (319)291-4323 LDescription Total Price j REINSPECTION FEE 3RD $250.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24076 11/16/2023 12/20/2023 2024-00000107 $250.00 Less Prepayment $0.00 Total Due $250.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE tilt INSPECTION REPORT 1125-1133 DIXON DRIVE CONDOMINIUMS BLDG, 1133 DOWN DR, Wi4TERLOt?IA S0741 \ R DETAILS Inspection Date: 11/16/2023 1 Inspection Type: Rental Inspection i Inspection Number: 11237 Shift: N/A Station: N/A I Unit: N/A I Lead Inspector:BARRY STRATTON i Other Inspectors: N/A j Fee:$250.00 . 1-#41(/'' -7—nl) STATUS CODE DESCRIPTION FAIL 1008.1 - Means of egress Illumination shall be provided in the means of egress in accordance with Section illumination. 1008.2. Under emergency power, means of egress illumination shall comply with Section 1008.3. Inspector: BARRY STRATTON-Comments:Egress lighting does not work.Today's inspections lights still do not work. Location: Not Provided FAIL 1032.2 Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector: BARRY STRATTON-Comments:Front door threshold is obstructing door from closing.Threshold is still not repaired. Rear door is missing door hardware. Trees in front,back,and along sides of building need cut back or removed so the egress paths are not blocked. Location: Not Provided FAIL 704.3-Opening protectives. Where openings are required to be protected, opening protectives shall be maintained self-closing or automatic-closing by smoke detection. Existing fusible-link- type automatic door-closing devices are permitted if the fusible link rating does not exceed 135°F(57°C). Inspector: BARRY STRATTON-Comments:Fire doors in open position. Fire doors still left in the open position on todays inspection,may require door closures installed on doors. Location: Not Provided Panted on'13,'.5i2©23 is 06.26 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 901.6- !nspection,testing and Fire detection and alarm systems,emergency alarm systems,gas detection systems, maintenance. fire-extinguishing systems,mechanical smoke exhaust systems and smoke and heat vents protection and life safety systems shall be maintained in an operative condition at all times,and shall be replaced or repaired where defective. Nonrequired fire protection and life safety systems and equipment shall be inspected,tested and maintained or removed in accordance with Section 901.8. Inspector:BARRY STRATTON-Comments:Alarm need maintenance and testing. Alarm testing still requires tested.Still not done. Location: Not Provided FAIL 906.1 -Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A, B, E,F, H, I,M, R-1,R-2, R-4 and S occupancies. Exceptions: 1.In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C. 2.In Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C.3. In storage areas of Group S occupancies where forklift, powered industrial truck or powered cart operators are the primary occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in accordance with all of the following:3.1.Use of vehicle-mounted extinguishers shall be approved by the fire code official.3.2. Each vehicle shall be equipped with a 10- pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not less than two spare extinguishers of equal or greater rating shall be available on-site to replace a discharged extinguisher.3.4.Vehicle operators shall be trained in the proper operation,use and inspection of extinguishers.3.5. Inspections of vehicle- mounted extinguishers shall be performed daily.2.Within 30 feet(9144 mm)distance of travel from commercial cooking equipment and from domestic cooking equipment in Group 1-1; 1-2,Condition 1;and R-2 college dormitory occupancies.3.In areas where flammable or combustible liquids are stored, used or dispensed.4.On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3316.1. 5.Where required by the sections indicated in Table 906.1.6.Special- hazard areas,including but not limited to laboratories,computer rooms and generator rooms,where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Inspector: BARRY STRATTON-Comments:Fire Extinguishers need updated.(2021). Fire extinguishers still out of date(2021). Location:Not Provided Printed on 11/16;2023 to 05.25 Page 2 of 4 STATUS CODE DESCRIPTION FAIL R4- Exterior Property Areas is the exterior property area maintained in a clean,safe,and sanitary condition?This includes grading and drainage,sidewalks and driveways,weeds,and pest infestations.(IPMC 302) Inspector: BARRY STRATTON-Comments:Front concrete slab at door. Busted concrete missing that is under slab.Concrete slab still broken and needs repaired. Trees/bushes blocking egress paths. Location: Not Provided FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector: BARRY STRATTON-Comments:Egress lights,fire extinguishers,fire doors, front door threshold. Location:Not Provided GENERAL NOTES BARRY STRATTON-11/16/2023 @ 06:25 9-7-6:DENIAL,SUSPENSION,REVOCATION OR NONRENEWAL:A.Grounds:The licensing officer or building official may revoke,suspend,deny or decline to renew any landlord license issued under section 9-7-4 of this chapter or any rental unit permit issued under section 9-7-5 of this chapter for any of the following grounds:3.Failure to correct deficiencies noted in notices of violation within the time specified in the notice. REINSPECTION DATE 12/13/2023 CONTACT SIGNATURE Caliber Group EJ' A�� Signed on:11/16/2023 @ 06:25 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 11/16/2023 @ 06:26 Printed on 11/16/Z023 t 06:26 Page 3 of 4 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON banystratton@waterloo-ia.org (319)231-9147 Pi-1,-,teo or, E,'.2023:2.1 OE LE, Page 4 of 4 ^ .^ WATERLOO ��0���� ��u�m�������m� ����� RESCUE INSPECTION REPORT » 2233-22S9 FAIRWAY LN 12 RENTAL UNITS,2233-2259 FAIRWAY LN, WArEM001AS0701 DETAILS Inspection mspectionDate: 11/U8/2O23 { Inspection Type: Rental Inspection ! Inspection Number: 111981 Shift: N/A 5t ion: N/A | Unit: N/A | Lead Inspector:BAKRvSTRATTON / Other Inspectors: N/A | Fee:$25o.- IA,— ` STATUS CODE DEnCRIwmNxmv FAIL 506.1 Where required. Where access to o/'within a structure or an area is restricted because of secured openings or where immediate access is necessary for life-saving or fire-fighting purposes,the fire code official is authorized to require a key box to be installed in an approved location.The key box shall be of an approved type listed in accordance with UL 1037,and shall contain keys to gain necessary access as required by the fire code official. Inspector,: UARRYSTRATTON Comments:Need to install Knox Box on front of building Location: Front of Listed Address FAIL 907.2.11 Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multip|escationsmoke installed\n accordance with Sections yO7.2.11.1 through 907.J.11.7 and NFAA72. alarms. Inspector: BARRYSTRATTON'[ommenzs:Need smoke detectors installed in all cmnmon hallways on all floors.Also need detectors installed in all bedrooms and outside bedrooms.All detectors shall be in working condition. Location:Common Hallways and all apartments. FAIL e15.1 Genera|. Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6.Carbon monoxide detection shall be iinstalled in existing buildings in accordance with Section 11[8.y. Inspector: BARRvSTRATTON Comments:Need to install CO detectors in vicinity ofall bedrooms in all apartments. Location: |n vicinity ofbedrooms GENERAL NO TES 8ARnvSTRATTOm 11x}8/202]@ 12:56 When items are completed please contact out deparnnentco do do a follow-up inspection to ensure building meets rental standards. |ce/ns aresri{/ not completed on this inspection date, `xn�zoza5 `�.,r REINSPECTION DATE 12/06/2023 CONTACT SIGNATURE D AND C MANAGEMENT LLC Signed on: 11/08/2023 @ 12:57 Cl/ )M(L INSPECTOR SIGNATURE BARRY STRATTON Signed on: 11/08/2023 @ 12:57 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 P ,ted on 11/03/20231.12:57 Page 2 of 2