RENTAL INSPECTION- 312 ALLEN ST-4-6-23 FOR BILLING INQUIRY: (319)291-4323
LDescription Total Price,
REINSPECTION FEE 3RD $250.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
22016 04/24/2023 05/25/2023 2023-00020397 $250.00
Less Prepayment $0.00
Total Due $250.00
City of Waterloo
. ' ^
WATERLOO �l\ Y�
��������v�n� ����� ������v�� �� > ^
INSPECTION REPORT
OWL INVESTMENTS LLC RENTAL UNIT,312 ALLEN ST, WA rERLOO JA S0701 W �=
DETAILS
-
Inspection Date:84/06/2023 1 Inspection Type: Rental Inspection 1 Inspection Numbecy782 Shift:
Unit: N/A Lead|nspectoc8ARRYSTRATTON { Other Inspectors: N/A I Fee:$2S08U
0-0
e7 �� ��
mnAnxS CODE DmmxomIPTxON
FAIL 1810.2 Door operations. Except as specifically permitted by this section, egress doors shall be readily
openab|e from the egress side without the use ofa key or special knowledge or
effort.
Inspector: BARRv5TRATTON Comments:Back door and jamb need replaced.
FAIL 1032.2 Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the rneans of egress is occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector: BARRYSTR/QTON Comments:Windows need replaced.
FAIL 603.2 Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions
conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official.
hazards. Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes Conditions that constitute an electrical shock or fire hazard
shall be abated not beused.
Inspector:8ARRvSTRATT0N Comments:Outlets pulling out of walls. Breakers keep
tripping out. Need licensed electrician to check out electric service.
FAIL 907.2.11 Single-and Listed single-and multiple-station smoke alarms complying with UL217shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.7 and NFPA 72.
alarms.
Inspector: 8ARRY6TRATTON Comments:Smoke detectors need maintenance.
Detectors beeping
FAIL R3 Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPMC
Occupancy 108.1.3)
Inspector:BAnRYSTRAlTON Comments:Lead levels
Printed=owo6/z02aQt,,3,
Page 1m*
STATUS CODE DESCRIPTION
FAIL R4- Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This
includes grading and drainage,sidewalks and driveways,weeds,and pest
infestations.(IPMC 302)
Inspector:BARRY STRATTON-Comments:
FAIL R5-Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and
sanitary state?(IPMC 304)
Inspector: BARRY STRATTON-Comments:Front deck
FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair, structurally sound,and in a sanitary condition?(IPMC 305)
Inspector: BARRY STRATTON-Comments: Dining room window needs replaced since
it is broken. Fram around window is rotten and needs replaced.Wall below window
the plaster is missing. Peeling paint, holes in walls back door and jamb need replaced,
sink cabinet has mold,cabinet doors missing,stove not working,cabinets need
replaced,vent covers missing on registers,mice,outlets,floors and baseboards in
bad condition allowing mice in unit,lead base paint levels detected in child,bedroom
window needs replaced,paneling loose in living room,deck boards loose on front
deck.
FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector: BARRY STRATTON-Comments:Lead levels
FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room
temperature of 68F?(IPMC 602.2)
Inspector: BARRY STRATTON-Comments:Not capable of maintaining 68 degrees in
unit.
FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector: BARRY STRATTON-Comments:
GENERAL NOTES
BARRY STRATTON-04/06/2023 @ 13:29 304.13 Window,skylight and door frames. Every window,skylight,door and frame shall
be kept in sound condition,good repair and weather tight.
Panted on 04105;2023^c 13:31
Page 2 of 4
•
GENERAL NOTES
BARRY STRATTON-04/06/2023 @ 13:29 304.14 Insect screens. During the period from[DATE]to[DATE],every door,window
and other outside opening required for ventilation of habitable rooms,food
preparation areas,food service areas or any areas where products to be included or
utilized in food for human consumption are processed, manufactured, packaged or
stored shall be supplied with approved tightly fitting screens of minimum 16 mesh per
inch(16 mesh per 25 mm),and every screen door used for insect control shall have a
self-closing device in good working condition.
BARRY STRATTON-04/06/2023 @ 13:29 304.15 Doors. Exterior doors,door assemblies, operator systems if provided,and
hardware shall be maintained in good condition. Locks at all entrances to dwelling
units and sleeping units shall tightly secure the door. Locks on means of egress doors
shall be in accordance with Section 702.3.
BARRY STRATTON-04/06/2023 @ 13:29 304.10 Stairways,decks,porches and balconies.Every exterior stairway,deck, porch
and balcony,and all appurtenances attached thereto,shall be maintained structurally
sound, in good repair,with proper anchorage and capable of supporting the imposed
loads.
BARRY STRATTON-04/06/2023 @ 13:29 305.1 General.The interior of a structure and equipment therein shall be maintained in
good repair,structurally sound and in a sanitary condition. Occupants shall keep that
part of the structure that they occupy or control in a clean and sanitary condition.
Every owner of a structure containing a rooming house, housekeeping units,a hotel, a
dormitory,two or more dwelling units or two or more nonresidential occupancies,
shall maintain, in a clean and sanitary condition,the shared or public areas of the
structure and exterior property
BARRY STRATTON-04/06/2023 @ 13:29 309.1 Infestation.Structures shall be kept free from insect and rodent infestation.
Structures in which insects or rodents are found shall be promptly exterminated by
approved processes that will not be injurious to human health.After pest elimination,
proper precautions shall be taken to prevent reinfestation.309.2 Owner.The owner of
any structure shall be responsible for pest elimination within the structure prior to
renting or leasing the structure. Mice in unit.
BARRY STRATTON-04/06/2023 @ 13:29 504.1 General. Plumbing fixtures shall be properly installed and maintained in working
order,and shall be kept free from obstructions, leaks and defects and be capable of
performing the function for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe,sanitary and functional condition.Bathtub will
need replaced.
BARRY STRATTON-04/06/2023 @ 13:29 504.3 Plumbing system hazards.Where it is found that a plumbing system in a
structure constitutes a hazard to the occupants or the structure by reason of
inadequate serviceinadequate venting,cross connection, backsiphonage,improper
installation,deterioration or damage or for similar reasons,the code official shall
require the defects to be corrected to eliminate the hazard.Water leak in basement.
Prnnted on 04,06 2023 13.31
Page 3 of 4
MP
GENERAL NOTES
BARRY STRATTON-04/06/2023 @ 13:29 605.1 Installation, Electrical equipment,wiring and appliances shall be properly
installed and maintained in a safe and approved manner.
BARRY STRATTON-04/06/2023 @ 13:30 304.5 Foundation walls. Foundation walls shall be maintained plumb and free from
open cracks and breaks and shall be kept in such condition so as to prevent the entry
of rodents and other pests.
BARRY STRATTON-04/06/2023 @ 13:30 9-7-7:INSPECTIONS REQUIRED:1.A re-inspection fee of fifty dollars($50.00)per unit if
not in compliance shall be charged for the first re-inspection.A re-inspection fee of one
hundred and fifty dollars($150.00)per unit shall be charged for the second re-
inspection.A re-inspection fee of two hundred and fifty dollars($250.00)per unit shall
be charged for the third re-inspection.
REINSPECTION DATE
05/04/2023
CONTACT SIGNATURE
John Greenly
Signed on:04/06/2023 @ 13:30
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:04/06/2023 @ 13:30