RENTAL INSPECTION - 3684 W 4TH ST-3-3-23 FOR BILLING INQUIRY: (319)291-4323
LDescription Total Price
REINSPECTION FEE 2ND $150.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
23270 04/24/2023 05/25/2023 2023-00020411 $150.00
Less Prepayment $0.00
Total Due--> $150.00
City of Waterloo
WATERLOO FIRE RESCUE
INSPECTION REPORT 01,
4:
30 SOMETHING REAL ESTATE LL,C 8-PLEX,3684 W 4TH ST, WATERLOO IA S0701
DETAILS
Inspection Date:03/03/2023 I Inspection Type: Rental Inspection Inspection Number:9599 I Shift: N/A 1 Station: N/A I
Unit: N/A I Lead Inspector:BARRY STRATTON f Other Inspectors: N/A I Fee:$150.00 Ol 2,14/
)794
STATUS CODE DESCRIPTION
FAIL 1008.1 -Means of egress Illumination shall be provided in the means of egress in accordance with Section
illumination. 1008.2. Under emergency power,means of egress illumination shall comply with
Section 1008.3.
Inspector:BARRY STRATTON-Comments:Egress lights not working by unit#7
FAIL 703.1 -Maintaining Materials and firestop systems used to protect membrane and through penetrations
protection. in fire-resistance-rated construction and construction installed to resist the passage
of smoke shall be maintained.The materials and firestop systems shall be securely
attached to or bonded to the construction being penetrated with no openings visible
through or into the cavity of the construction.Where the system design number is
known,the system shall be inspected to the listing criteria and manufacturer's
installation instructions.
Inspector:BARRY STRATTON-Comments:Fire doors held in open position and need
to remain closed.
FAIL 705.2-Inspection and Opening protectives in fire-resistance-rated assemblies shall be inspected and
maintenance. maintained in accordance with NFPA 80.Opening protectives in smoke barriers shall
be inspected and maintained in accordance with NFPA 80 and NFPA 105.Openings in
smoke partitions shall be inspected and maintained in accordance with NFPA 105.
Fire doors and smoke and draft control doors shall not be blocked,obstructed,or
otherwise made inoperable. Fusible links shall be replaced promptly whenever fused
or damaged. Opening protectives and smoke and draft control doors shall not be
modified.
Inspector:BARRY STRATTON-Comments:
Printed on 03.,0312023 L 13:14
Page 1 of 4
STATUS CODE DESCRIPTION
FAIL 906.1 -Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.In new
and existing Group A,B,E,F,H, I,M, R-1,R-2, R-4 and S occupancies. Exceptions:1.In
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A:10-B:C.2.In Group E occupancies,
portable fire extinguishers shall be required only in locations specified in Items 2
through 6 where each classroom is provided with a portable fire extinguisher having
a minimum rating of 2-A:20-B:C.3. In storage areas of Group S occupancies where
forklift,powered industrial truck or powered cart operators are the primary
occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in
accordance with all of the following:3.1.Use of vehicle-mounted extinguishers shall
be approved by the fire code official.3.2. Each vehicle shall be equipped with a 10-
pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket
approved by the extinguisher manufacturer or the fire code official for vehicular use.
3.3. Not less than two spare extinguishers of equal or greater rating shall be available
on-site to replace a discharged extinguisher.3.4.Vehicle operators shall be trained in
the proper operation,use and inspection of extinguishers.3.5.Inspections of vehicle-
mounted extinguishers shall be performed daily.2.Within 30 feet(9144 mm)distance
of travel from commercial cooking equipment and from domestic cooking equipment
in Group I-1; I-2,Condition 1;and R-2 college dormitory occupancies.3.In areas where
flammable or combustible liquids are stored,used or dispensed.4.On each floor of
structures under construction, except Group R-3 occupancies, in accordance with
Section 3316.1,S.Where required by the sections indicated in Table 906.1.6.Special-
hazard areas, including but not limited to laboratories,computer rooms and
generator rooms,where required by the fire code official. Exception:Portable fire
extinguishers are not required at normally unmanned Group U occupancy buildings
or structures where a portable fire extinguisher suitable to the hazard of the location
is provided on the vehicle of visiting personnel.
Inspector: BARRY STRATTON-Comments:Fire extinguishers need maintenance and
replaced. Expired since 2012
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.7 and NFPA 72.
alarms.
Inspector:BARRY STRATTON-Comments:Smoke detectors need to be in working
condition.
FAIL 907.2.11.1 -Group R-1. Single-or multiple-station smoke alarms shall be installed in all of the following
locations in Group R-1: 1.1n sleeping areas.2.In every room in the path of the means
of egress from the sleeping area to the door leading from the sleeping unit.3.In each
story within the sleeping unit,including basements. For sleeping units with split levels
and without an intervening door between the adjacent levels,a smoke alarm installed
on the upper level shall suffice for the adjacent lower level provided that the lower
level is less than one full story below the upper level.
Inspector:BARRY STRATTON-Comments:Smoke detectors missing in common
hallways.
P:etnted on 03103,2023 g 14 14
Page 2 of 4
STATUS CODE DESCRIPTION
FAIL 915.1 -General. Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector:BARRY STRATTON-Comments:CO detector needs to be in working
condition.
FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector:BARRY STRATTON-Comments:Water damage in kitchen and bath room
mechanical closet. Removed all damage material and replace. Bath fan needs
cleaned. Peeling paint in bathroom needs corrected.Potential mold in kids closet and
kitchen.Mice in apartment need exterminated.Closets are very cold. Floors at
baseboards there is a lot of cold air coming in both closets. Need to insulate for
weatherization purposes.
FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room
temperature of 68F?(IPMC 602.2)
Inspector:BARRY STRATTON-Comments:Open duct in mechanical closet and return
air duct not attached.
FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector:BARRY STRATTON-Comments:Bath fan.Water heater in laundry room is
missing a discharge tube.
GENERAL NOTES
BARRY STRATTON-03/03/2023 @ 14:11 Holes in walls in laundry area need covered Still not corrected.
BARRY STRATTON-03/03/2023 @ 14:11 309.4 Multiple occupancy.The owner of a structure containing two or more dwelling
units,a multiple occupancy,a rooming house or a nonresidential structure shall be
responsible for pest elimination in the public or shared areas of the structure and
exterior property. If infestation is caused by failure of an occupant to prevent such
infestation in the area occupied,the occupant and owner shall be responsible for pest
elimination.Mice in unit#1
BARRY STRATTON-03/03/2023 @ 14:11 Corrections for Unit# 1 and common areas in complex.
Printed on 03103 2023: 14-14
Page 3 of 4
REINSPECTION DATE
04/03/2023
CONTACT SIGNATURE
Caliber Group L1V\KSigned on:03/03/2023 @ 14:12
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:03/03/2023 @ 14:12