WATERLOO FIRE RESCUE
(A)
INSPECTION REPORT v
ti\ ri#
400-402 WELLINGTON ST 4 PLEX,402 112 WELLINGTON ST,WATERLOO!A 50701 'E
DETAILS
Inspection Date:03/27/2023 I Inspection Type: Rental Inspection I Inspection Number:9719 I Shift: N/A I Station: N/A I
Unit: N/A I Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$50.00
619r-4//4( -)Z5 e
STATUS CODE DESCRIPTION
FAIL 1010.2-Door operations. Except as specifically permitted by this section,egress doors shall be readily
openable from the egress side without the use of a key or special knowledge or
effort.
Inspector:BARRY STRATTON-Comments:Door condition and jambs
FAIL. 603.2-Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions
conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official.
hazards. Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes Conditions that constitute an electrical shock or fire hazard
shall be abated not be used.
Inspector:BARRY STRATTON-Comments:Open electric boxes in closet and
basement. Romex in closet need to be in rigid pipe.
Prfntecl on 03l27 2023:r 1231
Page 1 of 5
,
STATUS CODE DESCRIPTION
FAIL 906.1 -Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.1n new
and existing Group A, B, E,F,H, I,M, R-1,R-2, R-4 and S occupancies.Exceptions: 1.1n
Group R-2 occupancies,portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A:10-B:C.2.In Group E occupancies,
portable fire extinguishers shall be required only in locations specified in Items 2
through 6 where each classroom is provided with a portable fire extinguisher having
a minimum rating of 2-A:20-B:C.3. In storage areas of Group S occupancies where
forklift,powered industrial truck or powered cart operators are the primary
occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in
accordance with all of the following:3.1. Use of vehicle-mounted extinguishers shall
be approved by the fire code official.3.2. Each vehicle shall be equipped with a 10-
pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket
approved by the extinguisher manufacturer or the fire code official for vehicular use.
3.3.Not less than two spare extinguishers of equal or greater rating shall be available
on-site to replace a discharged extinguisher.3.4.Vehicle operators shall be trained in
the proper operation,use and inspection of extinguishers.3.5.Inspections of vehicle-
mounted extinguishers shall be performed daily.2.Within 30 feet(9144 mm)distance
of travel from commercial cooking equipment and from domestic cooking equipment
in Group 1-1; 1-2,Condition 1;and R-2 college dormitory occupancies.3.In areas where
flammable or combustible liquids are stored, used or dispensed.4.On each floor of
structures under construction,except Group R-3 occupancies,in accordance with
Section 3316.1.5.Where required by the sections indicated in Table 906.1.6.Special-
hazard areas, including but not limited to laboratories,computer rooms and
generator rooms,where required by the fire code official. Exception: Portable fire
extinguishers are not required at normally unmanned Group U occupancy buildings
or structures where a portable fire extinguisher suitable to the hazard of the location
is provided on the vehicle of visiting personnel.
Inspector:BARRY STRATTON-Comments:
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.7 and NFPA 72.
alarms.
Inspector: BARRY STRATTON-Comments:Smoke detectors need to installed and in
working condition.Old detectors need removed.
FAIL 915.1 -General. Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector: BARRY STRATTON-Comments:CO Detector needed in vicinity of
bedrooms.
FAIL R5-Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and
sanitary state?(IPMC 304)
Inspector:BARRY STRATTON-Comments:Front porch column and front stairs.
Printed on 03/27i2023 E 12:31
Page 2 of 5
l ,
STATUS CODE DESCRIPTION
FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector:BARRY STRATTON-Comments:Front door to 402,ceiling missing tiles,tiles
damaged from leak,back door jamb needs replaced,broken windows need replaced,
door hardware missing on doors,peeling paint,paneling is coming loose from wall,
holes in floor,mice and cockroaches,drainage pipe in kitchen sink leaks and pipe not
allowed per plumbing code,rotten duct work in basement,water meter leaking,
cardboard screwed in to duct work for furnace(combustible material not allowed),
dryer not venting to the outside,handrail to basement needs replaced,drywall needs
installed to patch hole in stairway,porch column needs replaced.
FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room
temperature of 68F?(IPMC 602.2)
Inspector:BARRY STRATTON-Comments:Duct work
FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector:BARRY STRATTON-Comments:
GENERAL NOTES
BARRY STRATTON-03/27/2023 @ 12:28 309.1 Infestation.Structures shall be kept free from insect and rodent infestation.
Structures in which insects or rodents are found shall be promptly exterminated by
approved processes that will not be injurious to human health.After pest elimination,
proper precautions shall be taken to prevent reinfestation.
BARRY STRATTON-03/27/2023 @ 12:28 305.1 General.The interior of a structure and equipment therein shall be maintained in
good repair, structurally sound and in a sanitary condition. Occupants shall keep that
part of the structure that they occupy or control in a clean and sanitary condition.
Every owner of a structure containing a rooming house, housekeeping units,a hotel,a
dormitory,two or more dwelling units or two or more nonresidential occupancies,
shall maintain,in a clean and sanitary condition,the shared or public areas of the
structure and exterior property
BARRY STRATTON-03/27/2023 @ 12:28 304.15 Doors. Exterior doors,door assemblies,operator systems if provided,and
hardware shall be maintained in good condition. Locks at all entrances to dwelling
units and sleeping units shall tightly secure the door. Locks on means of egress doors
shall be in accordance with Section 702.3.
BARRY STRATTON-03/27/2023 @ 12:29 304.4 Structural members.Structural members shall be maintained free from
deterioration,and shall be capable of safely supporting the imposed dead and live
loads.Front pillar and front steps need replaced.
Printed on 03i27d2O23 12.31
Page 3 of 5
GENERAL NOTE
BARRY STRATTON-03/27/2023 @ 12:29 304.13 Window,skylight and door frames. Every window,skylight,door and frame shall
be kept in sound condition,good repair and weather tight.
BARRY STRATTON-03/27/2023 @ 12:29 504.1 General.Plumbing fixtures shall be properly installed and maintained in working
order,and shall be kept free from obstructions, leaks and defects and be capable of
performing the function for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe,sanitary and functional condition.
BARRY STRATTON-03/27/2023 @ 12:29 603.1 Mechanical equipment and appliances. Mechanical equipment,appliances,
fireplaces, solid fuel-burning appliances, cooking appliances and water heating
appliances shall be properly installed and maintained in a safe working condition,and
shall be capable of performing the intended function.
BARRY STRATTON-03/27/2023 @ 12:29 605.1 Installation. Electrical equipment,wiring and appliances shall be properly
installed and maintained in a safe and approved manner.
BARRY STRATTON-03/27/2023 @ 12:29 9-7-6:DENIAL,SUSPENSION,REVOCATION OR NONRENEWAL
BARRY STRATTON-03/27/2023 @ 12:29 9-7-9:OWNER AND TENANT RESPONSIBILITIES:A. Landlord: Every landlord or its agent,
in addition to being responsible for maintaining each rental unit in a sound structural
condition,shall be responsible for keeping that part of the building or premises which
it controls in a clean, sanitary and safe condition,including the shared or public areas
in a building containing two(2)or more rental units. In addition,every landlord or its
agent shall comply with the provisions of title 5,chapter 3,article B of this code,
granting housing protections to victims of domestic violence.
REINSPECTION DATE
04/24/2023
CONTACT SIGNATURE
LDN Properties LLC
Signed on:03/27/2023 @ 12:30
Printed sn 03(2712023 -12:31
Page 4 of 5
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:03/27/2023 @ 12:30
QUESTIONS ABOUT YOUR INSPECTION?
BARRY STRATTON
barry.stratton@waterloo-ia.org
(319)231-9147
Printed on 03 27,2723 12:31
Page 5 of 5