Loading...
HomeMy WebLinkAboutX CALIBER INVESTMENTS, INC. - 820 HANNA BOULEVARD OF W 4 7. INVOICE DATE DUE DATE INVOICE# TOTAL DUE tiA „:T! 08/12/2026 09/16/2026 2027-00000026 $50.00 � ' /4o 00, • •IU1■ II IIIU III • O b0S 7vtl% Customer#: 25037 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable X CALIBER INVESTMENTS, INC. 715 Mulberry St 622 PROSPECT AVENUE WATERLOO, IA 50703 SUITE B WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL PROP INSPECTION- 520 HANNA BLVD-08/04/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION FEE 1ST $50.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 25037 08/12/2026 09/16/2026 2027-00000026 $50.00 Less Prepayment $0.00 Total Due—> $50.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. x &tQJ IIC� (,, Sc ,ecS A'Vt e B Waterloo Fire Rescue S ' 1.00 TO t Inspection Report 425E.3rd Street BLDG 520 Hanna Boulevard-520 Hanna BLVD,Waterloo IA 50701-1910 INSPECTION DETAILS Inspection Date Inspection Type 7' Inspection Number 08104/2026 2015 IPMC Rental Inspection J REINSPECTION)c%-z�V�- 4 00 22098-R1 Lead Inspector Shift Station Unit NATE BEUSELING NIA NIA NIA Other Inspectors Randy Girsch SUMMARY OF INSPECTION 0 0 0 14 0 7 Passed codes Resolved violations Failed codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date NATE BEUSELING 0910312026 nate.beuseling@waterloo-ia.org GENERAL NOTES NATE BEUSELING-08/0412026 @ 12:02 At reinspection water heater still did not have proper permits and inspections,missing smoke detector in basement and upstairs bedrooms outlets still read open ground,50.00 Reinspection fee NATE BEUSELING-0413012026 @ 12:24 At time of inspection the living room Bedroom 1 and other outlets were not able to be tested due to location of furniture etc. NATE BEUSELING-04/3012026 @ 12:24 Property Safety Inspector-nate.beuseling@waterloo-ia.org-Work:319-291-4319(#8)-Cell:319-464-5605 NATE BEUSELING-04/3012026 @ 12:24 Re-inspection date is as posted on the inspection report.The rental unit's responsible personls shall contact prior to inspection date to set up time of re- inspection.If all corrections are made before scheduled inspection,you can call to set up an earlier re-inspection.Please give the appropriate notices to occupants of the unit/s.Owner or owner's agent must be present during the re-inspections.Failure to schedule a time on the date given or failure to keep the scheduled inspection will result in a$100.00 fee.Re-inspection fees may be assessed for re-inspections.Re-inspection fees start at$50,then$150, and$250 for all subsequent re-inspections.All appropriate keys to gain entry to locked units shall be readily available during re-inspections. NATE BEUSELING-04/3012026 @ 12:24 Iowa Administrative Code 661-210.3(7)d.After June 30,2021,a battery-powered smoke alarm listed in accordance with UL 217 that is newly installed or replaces an existing battery-powered smoke alarm must be powered by a nonremovable,non-replaceable battery that powers the alarm for at least ten years.The battery requirements of this subrule do not apply to a fire alarm,smoke detector,smoke alarm,or ancillary component that is electronically connected as a part of a centrally monitored or supervised alarm system;that uses a low-power,radio frequency wireless communication signal. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection GENERATED ON 8/4/26, 12:03 PM 1 OF 5 Caliber Property Management Date: CHECKLISTS y NATE BEUSELING 0810412026 GENERATED ON 8/4/26, 12:83 PM 2 OF 5 Reinspection Sia,us CodQ Description Fail 2015 IPMC 304.15-Doors Exterior doors,door assemblies,operator systems if Location:Front storm door provided,and hardware shall be maintained in good Comments:Tape found on inside of glass,and door failed to open condition.Locks at all entrances to dwelling units and and shut on own,repair to original function ability sleeping units shall tightly secure the door.Locks on means of egress doors shall be in accordance with Section 702.3, Fail 2015 IPMC 305.3-Interior surfaces Interior surfaces,including windows and doors,shall be Location:Bedroom 2 clockwise maintained in good,clean and sanitary condition.Peeling, Comments:Missing trim on wall by door way,to the left of the chipping,flaking or abraded paint shall be repaired,removed doorway facing out or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected. Fail 2015 IPMC 505.4-Water heating facilities Water heating facilities shall be properly installed,maintained Location:Basement and capable of providing an adequate amount of water to be Comments:Water heater installed with out proper permits and drawn at every required sink,lavatory,bathtub,shower and inspections,have licensed plumber take out permit and request laundry facility at a minimum temperature of 110°F(43°C).A inspection to close out water heater issue gas-burning water heater shall not be located in any bathroom,toilet room,bedroom or other occupied room normally kept closed,unless adequate combustion air is provided.An approved combination temperature and pressure-relief valve and relief valve discharge pipe shall be properly installed and maintained on water heaters Fail 2015 IPMC 605.2-Receptacles Every habitable space in a dwelling shall contain not less Location:Bedroom 2 clockwise than two separate and remote receptacle outlets.Every Comments:Receptacles read open ground shall be repaired or laundry area shall contain not less than one grounding-type replaced with 2 pronged or GFCI outlets receptacle or a receptacle with a ground fault circuit interrupter.Every bathroom shall contain not less than one receptacle.Any new bathroom receptacle outlet shall have ground fault circuit interrupter protection.All receptacle outlets shall have the appropriate faceplate cover for the location. Fail 2015 IPMC 605.2-Receptacles Every habitable space in a dwelling shall contain not less Location:Bedroom 3 clockwise than two separate and remote receptacle outlets.Every Comments:Receptacles read open ground shall be repaired or laundry area shall contain not less than one grounding-type replaced with 2 pronged or GFCI outlets receptacle or a receptacle with a ground fault circuit interrupter.Every bathroom shall contain not less than one receptacle.Any new bathroom receptacle outlet shall have ground fault circuit interrupter protection.All receptacle outlets shall have the appropriate faceplate cover for the location. Fail 2015 IPMC 605.3-Luminaires Every public hall,interior stairway,toilet room,kitchen, Location:basement room to right bathroom,laundry room,boiler room and furnace room shall Comments:Light fixture missing proper globe shall be replaced contain not less than one electric luminaire.Pool and spa luminaires over 15 V shall have ground fault circuit interrupter protection. GENERATED ON 8/4/26, 12:03 PM 3 OF 5 Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I-1 Single or multiple-station smoke alarms shall be installed and Location:Basement maintained in Groups R-2,R-3,R-4 and I-i regardless of Comments:No smoke detector present will add smoke detector occupant load at all of the following locations:1.On the compliant with UL 217 standard ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms.2.In each room used for sleeping purposes.3.In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics.In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels,a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level GENERATED ON 8/4/26, 12:03 PM 4 OF 5 Ed Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $50.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 8/4/26, 12:03 PM 5 OF 5