RENTAL PROP INSPECTION- 520 HANNA BLVD-08/04/26 FOR BILLING INQUIRY: (319)291-4323
Description Total Price
REINSPECTION FEE 1ST $50.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
25037 08/12/2026 09/16/2026 2027-00000026 $50.00
Less Prepayment $0.00
Total Due—> $50.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
x &tQJ IIC�
(,, Sc ,ecS A'Vt e B
Waterloo Fire Rescue S ' 1.00 TO
t Inspection Report 425E.3rd Street
BLDG 520 Hanna Boulevard-520 Hanna BLVD,Waterloo IA 50701-1910
INSPECTION DETAILS
Inspection Date Inspection Type
7' Inspection Number
08104/2026 2015 IPMC Rental Inspection J REINSPECTION)c%-z�V�- 4 00 22098-R1
Lead Inspector Shift Station Unit
NATE BEUSELING NIA NIA NIA
Other Inspectors
Randy Girsch
SUMMARY OF INSPECTION
0 0 0 14 0 7
Passed codes Resolved violations Failed codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
NATE BEUSELING 0910312026
nate.beuseling@waterloo-ia.org
GENERAL NOTES
NATE BEUSELING-08/0412026 @ 12:02
At reinspection water heater still did not have proper permits and inspections,missing smoke detector in basement and upstairs bedrooms outlets still
read open ground,50.00 Reinspection fee
NATE BEUSELING-0413012026 @ 12:24
At time of inspection the living room Bedroom 1 and other outlets were not able to be tested due to location of furniture etc.
NATE BEUSELING-04/3012026 @ 12:24
Property Safety Inspector-nate.beuseling@waterloo-ia.org-Work:319-291-4319(#8)-Cell:319-464-5605
NATE BEUSELING-04/3012026 @ 12:24
Re-inspection date is as posted on the inspection report.The rental unit's responsible personls shall contact prior to inspection date to set up time of re-
inspection.If all corrections are made before scheduled inspection,you can call to set up an earlier re-inspection.Please give the appropriate notices to
occupants of the unit/s.Owner or owner's agent must be present during the re-inspections.Failure to schedule a time on the date given or failure to keep
the scheduled inspection will result in a$100.00 fee.Re-inspection fees may be assessed for re-inspections.Re-inspection fees start at$50,then$150,
and$250 for all subsequent re-inspections.All appropriate keys to gain entry to locked units shall be readily available during re-inspections.
NATE BEUSELING-04/3012026 @ 12:24
Iowa Administrative Code 661-210.3(7)d.After June 30,2021,a battery-powered smoke alarm listed in accordance with UL 217 that is newly installed or
replaces an existing battery-powered smoke alarm must be powered by a nonremovable,non-replaceable battery that powers the alarm for at least ten
years.The battery requirements of this subrule do not apply to a fire alarm,smoke detector,smoke alarm,or ancillary component that is electronically
connected as a part of a centrally monitored or supervised alarm system;that uses a low-power,radio frequency wireless communication signal.
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
GENERATED ON 8/4/26, 12:03 PM 1 OF 5
Caliber Property Management Date:
CHECKLISTS
y
NATE BEUSELING 0810412026
GENERATED ON 8/4/26, 12:83 PM 2 OF 5
Reinspection
Sia,us CodQ Description
Fail 2015 IPMC 304.15-Doors
Exterior doors,door assemblies,operator systems if Location:Front storm door
provided,and hardware shall be maintained in good Comments:Tape found on inside of glass,and door failed to open
condition.Locks at all entrances to dwelling units and and shut on own,repair to original function ability
sleeping units shall tightly secure the door.Locks on means
of egress doors shall be in accordance with Section 702.3,
Fail 2015 IPMC 305.3-Interior surfaces
Interior surfaces,including windows and doors,shall be Location:Bedroom 2 clockwise
maintained in good,clean and sanitary condition.Peeling, Comments:Missing trim on wall by door way,to the left of the
chipping,flaking or abraded paint shall be repaired,removed doorway facing out
or covered.Cracked or loose plaster,decayed wood and
other defective surface conditions shall be corrected.
Fail 2015 IPMC 505.4-Water heating facilities
Water heating facilities shall be properly installed,maintained Location:Basement
and capable of providing an adequate amount of water to be Comments:Water heater installed with out proper permits and
drawn at every required sink,lavatory,bathtub,shower and inspections,have licensed plumber take out permit and request
laundry facility at a minimum temperature of 110°F(43°C).A inspection to close out water heater issue
gas-burning water heater shall not be located in any
bathroom,toilet room,bedroom or other occupied room
normally kept closed,unless adequate combustion air is
provided.An approved combination temperature and
pressure-relief valve and relief valve discharge pipe shall be
properly installed and maintained on water heaters
Fail 2015 IPMC 605.2-Receptacles
Every habitable space in a dwelling shall contain not less Location:Bedroom 2 clockwise
than two separate and remote receptacle outlets.Every Comments:Receptacles read open ground shall be repaired or
laundry area shall contain not less than one grounding-type replaced with 2 pronged or GFCI outlets
receptacle or a receptacle with a ground fault circuit
interrupter.Every bathroom shall contain not less than one
receptacle.Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection.All receptacle
outlets shall have the appropriate faceplate cover for the
location.
Fail 2015 IPMC 605.2-Receptacles
Every habitable space in a dwelling shall contain not less Location:Bedroom 3 clockwise
than two separate and remote receptacle outlets.Every Comments:Receptacles read open ground shall be repaired or
laundry area shall contain not less than one grounding-type replaced with 2 pronged or GFCI outlets
receptacle or a receptacle with a ground fault circuit
interrupter.Every bathroom shall contain not less than one
receptacle.Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection.All receptacle
outlets shall have the appropriate faceplate cover for the
location.
Fail 2015 IPMC 605.3-Luminaires
Every public hall,interior stairway,toilet room,kitchen, Location:basement room to right
bathroom,laundry room,boiler room and furnace room shall Comments:Light fixture missing proper globe shall be replaced
contain not less than one electric luminaire.Pool and spa
luminaires over 15 V shall have ground fault circuit
interrupter protection.
GENERATED ON 8/4/26, 12:03 PM 3 OF 5
Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I-1
Single or multiple-station smoke alarms shall be installed and Location:Basement
maintained in Groups R-2,R-3,R-4 and I-i regardless of Comments:No smoke detector present will add smoke detector
occupant load at all of the following locations:1.On the compliant with UL 217 standard
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms.2.In each room used for
sleeping purposes.3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics.In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels,a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
GENERATED ON 8/4/26, 12:03 PM 4 OF 5