Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ALL RESIDENTIAL SERVICES, LLC - 2810 GERALDINE #13 & #14
WA rF INVOICE DATE DUE DATE INVOICE# TOTAL DUE c 08/12/2026 09/16/2026 2027-00000058 $80.00 r U fff/�w. • •ill 1■ II III II I I • T —T4*0 O Customer#: 25035 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable ALL RESIDENTIAL SERVICES, LLC 715 Mulberry St P.O. BOX 665 WATERLOO, IA 50703 CEDAR FALLS,IA 50613-0665 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-2810 GERALDINE#13&14- FOR BILLING INQUIRY: (319)291-4323 8/7/26 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 25035 08/12/2026 09/16/2026 2027-00000058 $80.00 Less Prepayment $0.00 Total Due —> $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Al/ Res-,dex ,a) SrVrcces L �, D,by $.. 61o5 Waterloo Fire Rescue d c { -1--"- 6 13-0 �_ t. ,,, Inspection Report I I- (��JI(rU 425 E.3rd Street 4400 All Residential Services LLC-2811- _ - -2817 Geraldine RD,BLDG 2811- 2813-2815-2017 Geraldine Road aterloo IA 50703 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 08/07/2026 Annual Inspection(1Yr) < S *60, 23679 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA NIA Other Inspectors JEREMIAH VANDYKE SUMMARY OF INSPECTION 022 09 ® 46 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: BRAD BALDWIN Reinspection Date brad.baldwin@waterloo-ia.org,3192914319 09/04/2026 GENERAL NOTES BRAD BALDWIN-08/07/2026 @ 14:58 Complaint received of possible sleeping in storage unit cause of inspection.Bed was not witnessed but recliners are present inside unit.Sleeping in storage unit is strictly prohibited. a rel4iitil 1 ,•* _ BRAD BALDWIN-08/07/2026 @ 15:01 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(Ext:0)-Cell:319-230-1224 BRAD BALDWIN-08/07/2026©15:01 •S80 annual inspection fee BRAD BALDWIN-08/07/2026 @ 15:04 GENERATED ON 8/7/26, 3:06 PM 1 OF 5 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-0810712026 @ 15:05 Re-inspection is scheduled for 914/26,contact inspector to schedule specific time. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Luis Garcia-2026 Date: BRAD BALDWIN 0810712026 CHECKLISTS Additional Codes Cc,,_. Description Fail 102.4-Application of building code. The design and construction of new structures shall comply Location:Mezzanine permit with the International Building Code,and any alterations, Comments:Permit holder(Owner)shall obtain inspection of additions,changes in use or changes in structures required mezzanine constructed.Contact Building Inspections Dept.at 319- by this code,which are within the scope of the International 291-4319 for inspection.Failure to complete inspection process may Building Code,shall be made in accordance therewith. result in"DO NOT OCCUPY"status of units. Fail 102.4-Application of building code. The design and construction of new structures shall comply Location:Electrical Permit with the International Building Code,and any alterations, Comments:Contractor(Greater Good Electrical)shall obtain additions,changes in use or changes in structures required inspection of work completed. by this code,which are within the scope of the International Building Code,shall be made in accordance therewith. Fail 5303.5.3-Securing compressed gas containers,cylinders Location:Shelves below mezzanine and tanks. Compressed gas containers,cylinders and tanks shall be Comments:All compressed cylinder tanks shall be secured with secured to prevent falling caused by contact,vibration or chain or other approved means to avoid tip-over hazard. seismic activity.Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints.2.Securing containers,cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers,cylinders or tanks. 3.Nesting of compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public.Nesting shall be allowed provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct the required means of egress. 4.Securing of compressed gas containers,cylinders and tanks to or within a rack,framework,cabinet or similar assembly designed for such use.Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. zoF 5 GENERATED ON 8/7/26, 3:08 PM Electrical Safety status Coy;,, Description Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:Receptacle next to electric panel Identified electrical hazards shall be abated.Identified Comments:Replace damaged outlet hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Electric panel prohibited.Approved covers shall be provided for all switch Comments:Openings in panel shall be corrected to avoid shock and electrical outlet boxes. hazard. • tt ip j ., to 1 to ie } Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:NE corner outlet above overhead door prohibited.Approved covers shall be provided for all switch and electrical outlet boxes. Comments:Install missing outlet cover. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:NW interior corner for permanent wiring and shall be listed and labeled in accordance with UL 817.Extension cords and flexible Comments:Remove extension cord in"lounge area",extension cordsshall not be affixed to structures,extended through cords shall not be used as permanent wiring walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 8/7/26, 3:06 PM 3 OF 5 Portable Fire Extingusihers Status Cod" Description Fail 906.2-General requirements. Portable fire extinguishers shall be selected,installed and Comments:Provide annual service to extinguisher,currently missing maintained in accordance with this Section and NFPA 10. date of last service.Purchasing new extinguisher requires taping Exceptions:1.The distance of travel to reach an extinguisher receipt of purchase to bottom of extinguisher for renewal date shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Fail 906.6-Unobstructed and unobscured. Portable fire extinguishers shall not be obstructed or Location:Between overhead doors obscured from view.In rooms or areas in which visual Comments:Relocate extinguisher to conspicuous location with obstruction cannot be completely avoided,means shall be unobstructed access or remove obstruction(workbench)blocking provided to indicate the locations of extinguishers. access to extinguisher. 4 OF 5 GENERATED ON 8/7/26, 3:06 PM Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 8/7/26, 3:06 PM 5 OF 5