Loading...
HomeMy WebLinkAboutCASEY'S 218 - 4010-4018 UNIVERSITY AVENUE OF WA? INVOICE DATE DUE DATE INVOICE# TOTAL DUE 0 08/12/2026 09/16/2026 2027-00000060 $80.00 �di0 . /* C • •nuuImuw • ) �-=ir 0 Customer#: 3448 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable CASEY S 218 715 Mulberry St 4014 UNIVERSITY AV WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-4010-4018 UNIVERSITY AVE- FOR BILLING INQUIRY: (319)291-4323 08/06/26 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES • 3448 08/12/2026 09/16/2026 2027-00000060 $80.00 Less Prepayment $0.00 Total Due -* $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue )\k Inspection Report 425 E.3rd Street .M,• Casey's 218 Pub-4010-4018 University AVE,BLDG 4010-4018 University Ave, Waterloo IA 50701 INSPECTION DETAILS Inspection Datc Inspection Type 2 Inspection Number 3Y08106/2026 Annual Inspection(1Yr) T 4 4 20.t° 17765 Lead Inspector Shift Station Una BRAD BALDWIN N/A N/A N/A Other Inspectors NIA SUMMARY OF INSPECTION 0 37 0 16 ® 27 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 09/02/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-08107/2026 @ 12:20 •$80 annual inspection fee BRAD BALDWIN-08/0712026 @ 12:20 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-08/07/2026 @ 12:20 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-08/07/2026 @ 12:20 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and S200 for all subsequent re-inspections. BRAD BALDWIN-08/07/2026 @ 12:24 Iowa Smoke Free Air Act:Outdoor patio is prohibited from allowing smoking events due to meeting requirements of an enclosed area in a bar. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Tony Perry 2026 Date:— BRAD BALDWIN 08/11/2026 CHECKLISTS GENERATED ON 8/11/26, 3;17 PM 1 OF 10 Means of Egress Code Description Fail 1032.3-Obstructions. A means of egress shall be free from obstructions that would Location:NW exit prevent its use,including the accumulation of snow and ice. Comments:Downspout drain tile shall be removed from path of egress exiting out of building. • 4-40\ -.1111 2 OF 10 GENERATED ON 8/11/28, 3:17 PM Additional Codes Status Code Description Fail 102.4-Application of building code. The design and construction of new structures shall comply Location:Furnace-Near Beer Garden with the International Building Code,and any alterations, Comments:Licensed mechanical contractor shall obtain permit and additions,changes in use or changes in structures required inspection for furnace installed without permit. by this code,which are within the scope of the International Building Code,shall be made in accordance therewith. if 11 rr � t Fail 5303.5.3-Securing compressed gas containers,cylinders U and tanks. Location:Bar CO2 closet Compressed gas containers,cylinders and tanks shall be Comments:Secure compressed gas cylinders with chain to avoid tip secured to prevent falling caused by contact,vibration or over. seismic activity.Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints.2.Securing containers,cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers,cylinders or tanks. 3.Nesting of compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public.Nesting shall be allowed provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct the required means of egress. 4.Securing of compressed gas containers,cylinders and tanks to or within a rack,framework,cabinet or similar assembly designed for such use.Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. GENERATED ON 8/11/26, 3:17 PM 3 OF 10 Fail 5303.5.3-Securing compressed gas containers,cylinders and tanks. Location:North storage area with overhead door Compressed gas containers,cylinders and tanks shall be Comments:Secure compressed gas cylinders with chain to avoid tip secured to prevent falling caused by contact,vibration or over. seismic activity.Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints.2.Securing containers,cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers,cylinders or tanks. 3.Nesting of compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers' • warehouses not open to the public.Nesting shall be allowed provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct the required means of egress. 4.Securing of compressed gas containers,cylinders and tanks to or within a rack,framework,cabinet or similar assembly designed for such use.Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. Emergency Equipment STaiu; Code Description Fail 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required Location:SW exit near billiards area in Section 1013.6.3.The system shall be capable of powering Comments:Repair or replace exit sign that failed to illuminate during the required load for a duration of not less than 90 minutes. test. 4 OF 10 GENERATED ON 8/11/28, 3:17 PM Electrical Safety S:s.sis Code Description Fail 603.4.1-Labeling. Doors into electrical control panel rooms shall be marked Location:Mechanical room near Beer Garden with a plainly visible and legible sign stating"ELECTRICAL Comments:Provide approved permanent signage on door indicating ROOM"or similar approved wording.The disconnecting 'ELECTRICAL PANEL"to door.Laminated paper will not be accepted. means for each service,feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident.Where buildings or structures are supplied by more than one power source,markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. Fail 603.5.3-Installation. Relocatable power tap cords shall not extend through walls, Location:West billiards area-South wall ceilings,floors,under doors or floor coverings,or be subject Comments:Add second screw/nail to support to environmental or physical damage. power strip to avoid hanging by wires. fur ii _ :r% s ' ,_._ ,... 4 , 4.1 i, ._ _ ..._. _ _ .. \ GENERATED ON 8/11/28, 3:17 PM 5 OF 1.0 Fail 603.5.3-Installation. Relocatable power tap cords shall not extend through walls, Location:West billiards area ceilings,floors,under doors or floor coverings,or be subject Comments:Properly support power strip to avoid hanging by wires to environmental or physical damage. • "i+ • -t • Fail 603.5.3-Installation. Relocatable power tap cords shall not extend through walls, Location:Casino games near bar ceilings,floors,under doors or floor coverings,or be subject Comments:Power strip behind games shall be properly mounted to to environmental or physical damage. avoid hanging by wires. 6 OF 10 GENERATED ON 8/11/26, 3:17 PM Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Mechanical closet near kitchen for permanent wiring and shall be listed and labeled in Comments:Remove yellow extension cord.Approved to replace with accordance with UL 817.Extension cords and flexible ro erl su cordsshall not be affixed to structures,extended through e p y pported power strip with manual reset for low wattage electronics only. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. .rrm; ir. iiit 17. iilor / \ s r1`'x 7 4 ' - ! ' . ,11 ,..... .; Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Bar-Above sinks for permanent wiring and shall be listed and labeled in Comments:Remove flexible supply cord from above drop ceiling, accordance with UL 817.Extension cords and flexible flexible wiring shall not extend through concealed spaces. cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Bar-Above"Ole Smoky"mini fridge for permanent wiring and shall be listed and labeled in Comments:Remove brown extension cord,shall not be used as accordance with UL 817.Extension cords and flexible permanent wiring.Would approve replacing with properly supported cordsshall not be affixed to structures,extended through pp p 9 c p Y power strip with manual reset for low wattage electronics only. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 8/11/28, 3:17 PM 7 OF 1a Commercial Cooking Hood Suppression System Description Fail 606.3.3-Cleaning. Hoods,grease-removal devices,fans,ducts and other Location:Kitchen hood exhaust appurtenances shall be cleaned at intervals as required by Comments:Exhaust system cleaning 283 days past due.Provide Sections 606.3.3.1 through 606.3.3.3. cleaning and report to be uploaded to Compliance Engine with any deficiencies corrected. Fail 606.3.3.1-Inspection. Hoods,grease-removal devices,fans,ducts and other Location:Kitchen hood suppression system appurtenances shall be inspected at intervals specified in Comments:Provide suppression system inspection report with any Table 606.3.3.1 or as approved by the fire code official. deficiencies corrected.Contractor must upload report to Compliance Inspections shall be completed by qualified individuals. Engine.Currently 238 days past due. GENEP'TED ON 8/1.1/26, 3:17 PM 8 OF 10 Portable Fire Extingusihers Status Co:,,. Description Fail 906.2-General requirements. OPortable fire extinguishers shall be selected,installed and Comments:Provide annual service to all extinguishers currently due maintained in accordance with this section and NFPA 10. August 2026 Exceptions:1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Fail 906.6-Unobstructed and unobscured. 1 Portable fire extinguishers shall not be obstructed or Location:Kitchen obscured from view.In rooms or areas in which visual Comments:Remove signage indicating location of extinguisher.obstruction cannot be completely avoided,means shall be provided to indicate the locations of extinguishers. Extinguisher has been relocated t k 1 l ,, ti tiff ,. if 4" Ll N k- A f/ GENERATED ON S/11/28, 3:17 PM 9 OF 10 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA II 10 OF 10 GENERATED ON 8/11/26, 3:17 PM